Func.
Name
Code

[O] input active range
start voltage

[O] input active range
end voltage

[O] input start frequency
enable

Analog input filter

EzSQ function select

Multi-speed operation
selection

Multi-speed freq. 0

Multi-speed freq. 0,
nd
2
motor

Multi-speed freq. 1 to
15
to
(for both motors)


Jog frequency

Jog stop mode
"A" Function
Description
The starting point (offset) for
the active analog input range,
range is 0. to 100 %.
The ending point (offset) for
the active analog input range,
range is 0. to 100.%
Two options; select codes:
Use offset ( value)
Use 0 Hz
Range n = 1 to 31,
1 to 30 : ×2ms filter
31: 500ms fixed filter with ±
0.1 kHz hysteresis.
Select codes:
Disable
Activate by PRG terminal
Activate always
Select codes:
...Binary operation (16
speeds selectable with 4
terminals)
...Bit operation (8 speeds
selectable with 7
terminals)
Defines the first speed of a
multi-speed profile, range is
0.00 / start frequency to 400
Hz
Defines the first speed of a
multi-speed profile or a 2nd
motor, range is 0.00 / start
frequency to 400 Hz
Defines 15 more speeds,
range is 0.00 / start frequency
to 400 Hz.
=Speed 1 to
=Speed15
Defines limited speed for jog,
range is from start frequency
to 9.99 Hz
Define how end of jog stops
the motor; six options:
Free-run stop (invalid
during run)
Controlled deceleration
(invalid during run)
DC braking to
stop(invalid during run)
Free-run stop (valid
during run)
Controlled deceleration
(valid during run)
DC braking to stop(valid
during run)
A
52
Defaults
B
Initial data
0.
100.
01
8.
00
00
6.0
6.0
0.0
6.00
04
Units
%
%
Spl.
-
-
Hz
Hz
Hz
Hz

Advertisement