Standard Functions
NOTE:. Parameters marked with "" in A column are accessible even in inverter running.
Parameters marked with "" in B column are accessible even in inverter running when in
the high level access mode, which means that b031 is set to "10".
Func.
Name
Code

Frequency source

Frequency source,
nd
2
motor

Run command source

Run command source,
nd
2
motor

Base frequency

Base frequency,
nd
2
motor

Maximum frequency

Maximum frequency,
nd
2
motor

[AT] selection

[O] input active range
start frequency

[O] input active range
end frequency
"A" Function
Description
Eight options; select codes:
POT on ext. operator
*Valid when connecting the
OPE-SR/SRmini
Control terminal
*Set to "01" when connecting
the WJ-VL or External volume
via control terminal
Function F001 setting
Modbus network input
Option
via EzSQ
Calculate function output
Four options; select codes:
Control terminal
Run key on keypad, or
digital operator
Modbus network input
Option
Settable from 30 Hz to the
maximum frequency()
Settable from 30 Hz to the 2
maximum frequency()
Settable from the base
frequency to 400 Hz
Settable from the 2
frequency to 400 Hz
Three options; select codes:
...Select between [O] and
[OI] at [AT] (ON=OI,
OFF=O)
...Select between [O] and
external POT at [AT]
(ON=POT, OFF=O)
...Select between [OI] and
external POT at [AT]
(ON=POT, OFF=OI)
The output frequency
corresponding to the analog
input range starting point,
range is 0.00 to 400.0 Hz
The output frequency
corresponding to the analog
input range ending point,
range is 0.00 to 400.0 Hz
A
nd
nd
base
51
Defaults
B
Initial data
01
01
01
01
50.0
50.0
50.0
50.0
00
0.00
0.00
Units
Hz
Hz
Hz
Hz
Hz
Hz