Download Print this page

Hitachi WL200 Series Basic Manual page 32

Hide thumbs Also See for WL200 Series:

Advertisement

The two diagrams below input wiring circuits using the inverter's internal +24V supply.
Each diagram shows the connection for simple switches, or for a field device with
transistor outputs. Note that in the lower diagram, it is necessary to connect terminal [L]
only when using the field device with transistors. Be sure to use the correct connection of
the jumper wire shown for each wiring diagram.
Sinking Inputs, Internal Supply
= [PLC] – [P24] position
Jumper wire
Field device
GND
1
7
Open collector outputs,
NPN transistors
Sourcing Inputs, Internal Supply
= [PLC] – [L] position
Jumper wire
Common to
Field device
[P24]
1
7
to PNP bias
GND
circuits
PNP transistor
sourcing outputs
Jumper wire
P24
Input common
PLC
Logic GND
L
1
7
Input switches
Jumper wire
P24
Input common
PLC
L
Logic GND
1
7
Input switches
30
WL200
24V
+
-
Input
circuits
WL200
24V
+
-
Input
circuits

Advertisement

loading