Notification Log - Canon VB-R13VE H2 Manual

Table of Contents

Advertisement

ONVIF warning (RTP)
R101 RTP session timeout [notice]
Description
session timeout: session ID=%1
(R101)
%1
Session ID
Meaning
RTP session has timed out.
R102 Information acquisition failure (RTP
payload size) [notice]
Description
cannot get parameter:
RTP_payload_size (R102)
Meaning
Information acquisition has failed (RTP
payload size).
R102 Information acquisition failure (IP
address) [notice]
Description
cannot get parameter: IP_address
(R102)
Meaning
Information acquisition has failed (IP
address).

Notification log

System notification
S001 System started [info]
Description
starting paramd (S001)
Meaning
Parameter management module
started.
S002 System settings changed [info]
Description
Updated system settings. (S002)
Meaning
Settings not requiring rebooting were
changed.
S010 Event service started [info]
Description
starting event (S010)
Meaning
The event service was started.
S011 Event service shut down [info]
Description
shutdown event (S011)
Meaning
The event service was shut down.
R103 RTSP authentication failure [notice]
Description
RTSP authorization error (R103)
Meaning
RTSP authentication has failed.
R107 RTSP connection failure [notice]
Description
RTSP Error: error_code=%d: Service
Unavailable (R107)
%d
400: Value used for RTSP is invalid.
401: RTSP authentication failure or
missing valid authentication
information.
457: Playback time for RTSP is invalid.
501: An invalid RTSP option was used.
503: Failure to offer service, due to
insufficient resources.
The number of maximum RTP
sessions, has passed the limit.
Meaning
RTSP connection has failed.
S012 External device service started [info]
Description
starting extio (S012)
Meaning
The external device input/output
service was started.
S013 External device service shut down
[info]
Description
shutdown extio (S013)
Meaning
The external device input/output
service was shut down.
S014 Timer service started [info]
Description
starting timer (S014)
Meaning
The timer service was started.
S015 Timer service shut down [info]
Description
shutdown timer (S015)
Meaning
The timer service was shut down.