Switch to an existing job
If the user selects "Always"; after tapping 1x or Start: the system shows a popup asking
to clear the envelopes or continue without clearing. The following two options are possible:
1.
The user chooses to clear the envelope:
a. The system start transporting envelopes present in the system to the exit. For safety
a maximum number of envelopes is processed. This maximum is set to 3.
b. If the system still detects envelopes after the maximum is reached, the system
shows a warning (INS-EH1-002) that there are still envelopes in the hopper that should
be removed.
c. When the user cancels the dialog with the 'X', the system returns to the Idle screen
without clearing or producing.
d. After clearing, the system returns to the idle screen.
2.
The user chooses to continue without clearing:
a. The system starts producing with the envelopes loaded in the system.
If the user selects "Ask"; after tapping 1x or Start: the system shows a popup asking to
clear the envelopes or continue without clearing. The following two options are possible:
1.
The user chooses to clear the envelope:
a. The system start transporting envelopes present in the system to the exit. For safety
a maximum number of envelopes is processed. This maximum is set to 3.
b. When the user cancels the dialog with the 'X', the system returns to the Idle screen
without clearing or producing.
c. After clearing, the system returns to the idle screen.
2.
The user chooses to continue without clearing:
a. The system starts producing with the envelopes loaded in the system.
If the user selects "Never" and envelope settings have not been changed; after tapping 1x
or Start: the system starts producing with the envelopes loaded in the system.
If the user selects "Never" and envelope settings have been changed; after tapping 1x or
Start: the system shows a popup asking to clear the envelopes or continue without
clearing. The following two options are possible:
1.
The user chooses to clear the envelope:
a. The system starts transporting envelopes present in the system to the exit. For
safety a maximum number of envelopes is processed. This maximum is set to 3.
b. When the user cancels the dialog with the 'X', the system returns to the Idle screen
without clearing or producing.
c. After clearing, the system returns to the idle screen.
2.
The user chooses to continue without clearing:
a. The system starts producing with the envelopes loaded.