The conditions are:
• No multi-feed is used for the BREs.
• The document directly under the BRE must have a height of at least 60 mm (2.4
inch) more than the BRE.
• The height of the BRE is more than the set fold length.
• The folding mode is either V-fold or C-fold (no Z-fold).
• The BRE must be shorter than the envelope height.
The whole BRE offset is based on friction between documents within a set. Therefore it is
necessary to make use of these conditions to reduce the risk of bad transporting, folding
and inserting.
AIMS settings
In case AIMS Mailpiece Id and Job Id is used in a barcode definition, the "Verification"
mode can be enabled. When set to "Verification" all mail pieces will be verified with the
AIMS server.
When switched to Off, the job will run normally but the mail pieces will not be verified with
the AIMS server.
It is possible to use the BRE offset for a BRE and an enclosure
(card) in one set. The extra condition is that this enclosure is equal
to or smaller than the set address fold and should be placed direct
underneath the BRE in the set.
4