4.3.2 Activating the Remote Control Mode 
a. Press and hold the MENU button for 3 seconds. 
b. Turn the Voltage control knob until the panel meter displays "rC Set" as shown below and 
then press the Voltage control knob to confirm entry into the remote control mode. 
c. Turn the Current control knob to select remote YES or NO. 
d. Press the Voltage control knob to confirm and to return to the Set menu. 
e. Press the Menu button to exit the Set menu. 
f. Details of the remote control mode are located in the dedicate Remote Control section later in 
this guide. 
Note: After activating the Remote Control Mode, all function keys located on the front panel will 
be locked (the Lock/Unlock button light switches ON). 
 
4.3.3 Deactivating the Remote Control Mode 
a. Press the Lock/Unlock button to unlock all of the function keys 
b. Repeat steps a to c in the 'Activating the Remote Control Mode' section above and set 
Remote Control to NO and then press the voltage control knob. 
 
4.3.4 Factory Default Reset 
a. Press and hold the MENU button for 3 seconds. 
b. Turn the Voltage control knob until the panel meter displays "FACS SEt" as shown below and 
then press the Voltage control knob to confirm entry into the Factory Reset mode. 
c. Turn the Current control knob to select Yes or No. 
d. Press the Voltage control knob to confirm and to return to the Set menu. 
e. Press the Menu button to exit the Set menu. 
f. The Power Supply will reboot and revert to its Factory Default settings. 
 
 
 
 
 
 
 
 