Specifications

Display: 3-3/4-digit LCD (3999 maximum reading)
Sampling Rate: 2 per second
Over Range Indication: "OL" or "-OL" appears on the display
Low Battery Indication:
Auto Power Off: 30 minutes after powered ON
Jaw Opening: 51 mm (2.01")
Overvoltage Category: Category III, 1000 Volts
Temperature Coefficient: 0.2 x (specified accuracy) per C below 18 C or above 28 C
Operating Conditions: 0 C to 50 C (32 F to 122 F), 0% to 75% relative humidity
Storage Conditions: -20 C to 60 C (-4 F to 140 F), 0% to 80% relative humidity
Remove battery
Pollution Degree: 2
Battery: 9-Volt battery (NEDA 1604, JIS 006P or IEC 6LF22)

Battery Replacement

Before opening the case, remove the jaw from the circuit and shut off the unit.
Failure to observe this warning can result in severe injury or death.
1.
Disconnect the unit from the circuit. Turn the unit OFF.
2.
Remove the screws from the back cover.
3.
Remove the back cover.
4.
Replace the battery (observe polarity).
5.
Replace the cover and screws.