Vel-33 - Thinklogical VelocityDVI-33 Product Manual

Single-link and dual-link fiber extension systems
Hide thumbs Also See for VelocityDVI-33:
Table of Contents

Advertisement

Tx STATUS LEDs
GREEN:
Fibers connected, good link
established.
ORANGE:
Local Status Mode selected, no
fiber link from Rx to Tx, or both DDC Mode
buttons held down (waiting to reload
default DDC table).
RED flashing:
No fiber link from Rx to Tx.
Rx STATUS LEDs
GREEN:
DVI monitor has good link to primary DVI
OUT port (labeled DDC).
ORANGE:
No DVI monitor connected to primary port
RED flashing:
No fiber link from Tx to Rx.
STATUS
STATUS
Digital Video Extension System - 33
Transmitter
Powered by
MRTS
Technology
The Primary Port on the Rx is used for DDC.
The Secondary Port carries video data only.
33
Digital Video Extension System -
QUICK START GUIDE
STEP 6:
6
Using the
supplied DVI-D male to
male cables, connect the
video output sources to
the Transmitter Unit's DVI
IN receptacles. Ensure
that all system functions
are operating properly.
L2
L1
DDC MODE
ACQUIRE
LCL REM
SELECT
DVI 1 OUT
DVI 1 IN
STEP 5:
Using the
supplied DVI-D male to
male cables, connect
5
the desired video output
devices to the
Transmitter Unit's DVI
OUT receptacles.
STATUS
Optical Fibers (up to 1000 meters)
available with ST-, SC- or LC-type
connectors
L2
L1
DDC MODE
ACQUIRE
LCL REM
DVI 1 OUT 1
DVI 1 OUT 2
SELECT
DDC
L3
L4
DDC MODE
DDC MODE
ACQUIRE
ACQUIRE
LCL REM
LCL REM
DVI 2 OUT
DVI 2 IN
DVI 3 OUT
SELECT
SELECT
L4
L3
DDC MODE
DDC MODE
ACQUIRE
ACQUIRE
LCL REM
LCL REM
DVI 2 OUT 1
DVI 2 OUT 2
DVI 3 OUT 1
SELECT
SELECT
DDC
DDC
3
Copyright
2013. All rights reserved. Printed in the U.S.A. All trademarks and service marks are the property of their respective owners.
4
CAUTION!
Replace with same type and rating fuse.
L5
L6
PWR
DVI 3 IN
T2A, 250 VAC
100-240V -, 0.5A, 50/60 Hz
STEP 4:
Power Switch is in the OFF
(0) position. Connect the
supplied AC Power Cord
(PWR-000006-R) to the
Transmitter's power
receptacle, plug it into a
standard AC source and
turn the unit ON (1).
STEP 1:
mode fiber optic cables
1
between the Tx and Rx
Units (up to 1000 meters).
Do not kink or pinch the
cables and be sure to keep
all bend radii to no less than
3 inches.
CAUTION!
Replace with same type and rating fuse.
L6
L5
PWR
DVI 3 OUT 2
100-240V -, 0.5A, 50/60 Hz
T2A, 250 VAC
2
STEP 3:
Using standard
DVI-D cables, connect the
desired video output
STEP 2:
Ensure that the Power Switch is
in the OFF (0) position. Connect the
devices to the Receiver
supplied AC Power Cord (PWR-000006-R)
Unit's DVI OUT receptacles.
For each of the three video
to the Receiver's power receptacle, plug it
into a standard AC source and turn the
output pairs, DVI OUT 1 is
unit ON (1).
the DDC port.
Ensure that the
Connect the multi-

Advertisement

Table of Contents
loading

Table of Contents