Dalsa P4-CC-04K07T User Manual page 43

Table of Contents

Advertisement

Piranha4 4K Color Camera User's Manual
Description
Internal line rate and exposure tim e
External line rate and exposure tim e
EXSYN C pulse controlling the line
rate. Program m ed exposure tim e
The p aram eters u sed to select the im aging m od es—trigger sou rces (sync), exp osu re tim e, and line rate—
are grou p ed together as the Cam era Controls.
Parameter
Line Rate (in H z)
Exp osu re Mod e
Exp osu re Tim e
Teledyne DALSA
Line Rate
Internal, program m able
Controlled by EXSYN C
pulse
Controlled by EXSYN C
pulse
Figure 15. Exposure controls
Camera Controls
Cam era line rate in H z. Only available w hen the start line trigger p aram eter is
d isabled (Trigger Mod e off).
Set the op eration m od e for the cam era's exp osu re.
Trigger Wid th or Tim ed . Trigger Wid th is only available w hen Trigger Mod e is
enabled .
Trigger Width
Uses the w id th of the cu rrent line trigger signal p u lse to control the exp osu re
d u ration.
Timed
The exp osu re d u ration tim e is set u sing the Exp osu re Tim e featu re and the
exp osu re starts w ith the Line Start event.
Exposure Time Selector
Internally generated . Allow s for an ind ep end ent exp osu re tim e to be ap p lied to
each ind ivid u al color.
Sets the exp osu re tim e (in m icrosecond s). Exp osu re Mod e featu re m u st be set
to Tim ed
Exposure Time
Internal program m able
External (EXSYN C)
Internal program m able
Description
43
Trigger Source
(Sync)
Internal
External
External
03-032-20180-00