Error Log Codes - Welbilt Frymaster FilterQuick 3FQG30U Installation, Operation And Maintenance Manual

Hide thumbs Also See for Frymaster FilterQuick 3FQG30U:
Table of Contents

Advertisement

One vat doesn't top off.
Controller displays
TOPOFF OIL
EMPTY /
CONFIRM
6.2.6 Error Log Codes (For FilterQuick™ Controller Only)
CODE
ERROR MESSAGE
E03
ERROR TEMP PROBE
FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E07
ERROR MIB SOFTWARE
E08
ERROR ATO BOARD
E09
ERROR PUMP NOT FILLING Dirty paper/pad and it needs changed or it was bypassed;
E10
ERROR DRAIN VALVE NOT
OPEN
E11
ERROR DRAIN VALVE NOT
CLOSED
E12
ERROR RETURN VALVE
NOT OPEN
E13
ERROR RETURN VALVE
NOT CLOSED
E14
ERROR AIF BOARD
E15
ERROR MIB BOARD
E16
ERROR AIF PROBE
E17
ERROR ATO PROBE
E20
INVALID CODE LOCATION
E21
FILTER PAPER
PROCEDURE ERROR
(Change Filter Paper)
A. Filter error exists.
B. Service required error exists
C. Solenoid, pump, pin issue, RTD
or ATO issue.
Top off system out of oil.
Temp probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F (210°C),
or in CE countries, 395°F (202°C)
A component has failed such as controller, interface
board, gas valve, ignition module or open-high limit.
Internal MIB software error
ATO board connection lost; ATO board failure
filter pump problem
Drain valve was trying to open and confirmation is
missing
Drain valve was trying to close and confirmation is
missing
Return valve was trying to open and confirmation is
missing
Return valve was trying to close and confirmation is
missing
MIB detects AIF missing; AIF board failure
Cooking controller detects MIB connections lost; Check
software version on each controller. If versions are
missing, check CAN connections between each
controller; MIB board failure
AIF RTD reading out of range
ATO RTD reading out of range
SD card removed during update
25 hour timer has expired or a dirty filter may be causing
an incomplete filtration.
A. Clear filter error properly. If problem persists
call your FAS for assistance.
B. Call your FAS for assistance.
C. Call your FAS for assistance.
Fill top off system with oil and press the 
(CONFIRM) button. Once the JIB is replaced press
and hold the orange reset button for ten (10)
seconds to reset top off system.
EXPLANATION
6-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frymaster filterquick fqg30 series

Table of Contents