Error Log Codes - Welbilt FRYMASTER FilterQuick FQE30 Installation, Operation And Maintenance Manual

Hide thumbs Also See for FRYMASTER FilterQuick FQE30:
Table of Contents

Advertisement

6.2.6 Error Log Codes (For FilterQuick™ Controller Only)
CODE
ERROR MESSAGE
E03
ERROR
TEMP
FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E07
ERROR MIB SOFTWARE
E08
ERROR ATO BOARD
E09
ERROR PUMP NOT FILLING
E10
ERROR DRAIN VALVE NOT
OPEN
E11
ERROR DRAIN VALVE NOT
CLOSED
E12
ERROR
RETURN
NOT OPEN
E13
ERROR
RETURN
NOT CLOSED
E14
ERROR AIF BOARD
E15
ERROR MIB BOARD
E16
ERROR AIF PROBE
E17
ERROR ATO PROBE
E20
INVALID CODE LOCATION
E21
FILTER PAPER PROCEDURE
ERROR (Change Filter Paper)
E22
OIL IN PAN ERROR
E25
RECOVERY FAULT
E27
LOW TEMP ALARM
E28
HIGH TEMP ALARM
E70
OQS TEMP HIGH
PROBE
Temp probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F (210°C), or in CE
countries, 395°F (202°C)
A component has failed such as controller, interface board, gas
valve, ignition module or open-high limit.
Internal MIB software error
ATO board connection lost; ATO board failure
Dirty paper/pad and it needs changed or it was bypassed; filter
pump problem
Drain valve was trying to open and confirmation is missing
Drain valve was trying to close and confirmation is missing
VALVE
Return valve was trying to open and confirmation is missing
VALVE
Return valve was trying to close and confirmation is missing
MIB detects AIF missing; AIF board failure
Cooking controller detects MIB connections lost; Check software
version on each controller. If versions are missing, check CAN
connections between each controller; MIB board failure
AIF RTD reading out of range
ATO RTD reading out of range
SD card removed during update
25 hour timer has expired or a dirty filter may be causing an
incomplete filtration.
Oil may be present in the filter pan.
Recovery time exceeded maximum time limit. Recovery time
should not exceed 1:40 for electric.
Oil temperature has dropped 30°F (17°C) lower than setpoint in
idle mode or 45°F (25°C) in cook mode. (This message may
appear if a product is dropped and the start cook button is not
pressed immediately or if too large of cook loads are dropped.)
Oil temperature has risen 40°F (22.2°C) higher than
setpoint. If temperature continues to rise, the high limit will shut the
burner off when temperature reaches 425°F (218°C) Non-CE or
395°F (202°C) CE.
Oil temperature is too high for a valid OQS reading. Filter at a
temperature between 300ºF (149ºC) and 375ºF (191ºC).