Welbilt Frymaster FilterQuick 3FQG30U Installation, Operation And Maintenance Manual page 33

Hide thumbs Also See for Frymaster FilterQuick 3FQG30U:
Table of Contents

Advertisement

Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil that may cause severe burns, slipping and falling.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
Use caution and wear appropriate safety equipment when resetting the filter pump
reset switch. Resetting the switch must be accomplished with care to avoid the
possibility of a serious burn from careless maneuvering around the drain tube and
frypot.
4.6 Draining and Refilling Vats, and Disposing of Oil
When cooking oil requires changing, drain the oil into an appropriate container for transport to the
disposal container. (For safe, convenient draining and disposal of used oil, Frymaster recommends
the use of the Frymaster Shortening Disposal Unit (SDU) for JIB systems. The SDU is available
through your local distributor.) Do not drain boil-out solution into an SDU. NOTE: If using
an SDU built before January 2004 the filter pan cover must be removed to allow the unit to be
positioned beneath the drain. To remove the cover, lift up on the front edge slightly and slip the oil
guard up and pull it straight out of the cabinet. Refer to the documentation furnished with your
disposal unit for specific operating instructions. If a shortening disposal unit is not available, allow
the oil to cool to 100°F (38°C), then drain the oil into a METAL container with a capacity of FOUR
(4) gallons (15 liters) or larger to prevent oil from spilling. If using a bulk oil system, follow the
disposal and refilling instructions for bulk oil in the FilterQuick Controller Manual 8197206.
When draining oil into an appropriate METAL container, make sure the container will
hold at least FOUR gallons (15 liters) or more, otherwise hot liquid could overflow
and cause injury.
DANGER
WARNING
WARNING
Filter Pump Reset Switch
DANGER
4-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Frymaster filterquick fqg30 series

Table of Contents