Error Log Codes - Welbilt Frymaster FilterQuick easyTouch Installation, Operation And Maintenance Manual

Hide thumbs Also See for Frymaster FilterQuick easyTouch:
Table of Contents

Advertisement

6.2.5

Error Log Codes

See section 1.12.2.1 in the FilterQuick™ easyTouch
access the Error Log.
Code
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL
SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND TOP
OFF DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E35
RETURN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E36
VALVE INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
E37
AUTOMATIC INTERMITTENT FILTRATION PROBE
FAILURE - FILTRATION DISABLED - CALL SERVICE
E39
CHANGE FILTER PAD
E41
OIL IN PAN ERROR
E42
CLOGGED DRAIN (Gas)
E43
OIL SENSOR FAILURE - CALL SERVICE
E44
RECOVERY FAULT
E45
RECOVERY FAULT – CALL SERVICE
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
E51
DUPLICATE BOARD ID - CALL SERVICE
E52
USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
E53
CAN BUS ERROR - CALL SERVICE
ERROR MESSAGE
®
Segmented Controller Manual for instructions to
TEMP Probe reading out of range
High limit temperature is past more than
410°F (210°C), or in CE countries, 395°F
(202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and
the high limit has failed to open. Immediately
disconnect power to the fryer and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked
out the ignition module.
ATO RTD reading out of range
Drain
valve
confirmation is missing
Drain
valve
confirmation is missing
Return valve was trying to open and
confirmation is missing
Return valve was trying to close and
confirmation is missing
Valve Interface Board connections lost or
board failure.
AIF RTD reading out of range.
25-hour timer has expired or dirty filter logic
has activated.
The system detects that oil may be present in
the filter pan.
Vat did not empty during filtration
Oil level sensor may have failed.
Recovery time exceeded maximum time limit.
Recovery time exceeded maximum time limit
for two or more cycles.
SIB board 1 connection lost or board failure.
Two or more controllers have the same
location ID.
The controller has an unknown error.
Communications are lost between boards.
6-7
EXPLANATION
was
trying
to
open
was
trying
to
close
and
and