Daikin Clima-Flex CLIFC FIXED Series Installation, Operation And Maintenance Manual

Daikin Clima-Flex CLIFC FIXED Series Installation, Operation And Maintenance Manual

Advertisement

Quick Links

CLIFC FIXED SERIES
FAN & COIL FIXED HORIZONTAL
400 / 600 / 800 / 1,000 / 1,200 /
1,300 / 1,600 / 2,000 CFM
INSTALATION, OPERATION AND
MAINTENANCE MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Daikin Clima-Flex CLIFC FIXED Series

  • Page 1 CLIFC FIXED SERIES FAN & COIL FIXED HORIZONTAL 400 / 600 / 800 / 1,000 / 1,200 / 1,300 / 1,600 / 2,000 CFM INSTALATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 2 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL THIS PAGE INTENTIONALLY LEFT BLANK CLIMA-FLEX...
  • Page 3: Table Of Contents

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Content Nomenclature ............4 Standard features ..........5 Maintenance warnings ........6 Maintenance ............7 Physical data .............8 Jobsite installation ......... 11 Electrical and sound data ......13 Electrical diagram ........... 14 Maintenance ............ 16 CLIMA-FLEX...
  • Page 4: Nomenclature

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Nomenclature CLIFC H 400 0 3 1 R C 0 P D N Unit type H - Horizontal Capacity 400 - 400 CFM 600 - 600 CFM 800 - 800 CFM 1000 - 1,000 CFM 1200 - 1,200 CFM 1300 - 1,300 CFM 1600 - 1,600 CFM...
  • Page 5: Standard Features

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Standard features STRUCTURE All F&C units are built with heavy gauge corrosion resistant galvanized steel. All units are approved for installation with “0” clearance to combustible materia MOTORS Standard motors are PSC, permanently lubricated type with internal thermal overload protection. PLENUM Return air plenums are manufactured from galvanized steel insulated with high-density anti-bacterial and anti-acus- tic foam.
  • Page 6: Maintenance Warnings

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Maintenance warnings Before attempting to perform any maintenance work whatsoever on the equipment, it is essential that the equipment is disconnected and completely isolated from the mains power suppl WARNING After disconnection of the mains power supply, a minimum of 1 minute should be allowed for any rotating parts to come to rest before access panels are removed.
  • Page 7: Maintenance

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Maintenance FILTERS Filters must be properly maintained in order to ensure proper air cleaning efficiency and to maintain design airflow. Acoustic output may also be adversely affected by dirty filter. The length of time between cleaning of filters is dependent upon the air condition. A three month cycle is normal, however more frequent maintenance may be required in some cases.There is one air filter fitted to the equipment in the inlet air path, upstream of the heat exchange coil.
  • Page 8: Physical Data

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Physical data 2 PIPE F&C CLIMA-FLEX...
  • Page 9 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Physical data (Cont’d.) 4 PIPE F&C (COLD / HOT) CLIMA-FLEX...
  • Page 10 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Physical data (Cont’d.) 4 PIPE F&C (COLD / HOT) CLIMA-FLEX...
  • Page 11: Jobsite Installation

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Jobsite installation Support structure Service clearance 500 mm Roof Return Air Suspension rod Unit Installation detail Sealing washer CLIMA-FLEX...
  • Page 12 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Jobsite installation (Cont’d.) TURBINE MOTOR ASSEMBLY CLIMA-FLEX...
  • Page 13: Electrical And Sound Data

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Electrical and sound data Noise values Speed Pressure Drop Model Low, Med, High (inWg) CFMs Sones FC Fix 400 57.3 47.6 FC Fix 400 60.8 51.8 FC Fix 400 62.7 54.1 FC Fix 600 59.2 48.7 FC Fix 600...
  • Page 14: Electrical Diagram

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Electrical diagram MODELS 400, 600, 600, 1,000, 1,300 WHITE BLACK BLUE ORANGE CLIMA-FLEX...
  • Page 15 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Electrical diagram (Cont’d.) MODELS 1,200, 1,600, 2,000 CLIMA-FLEX...
  • Page 16: Maintenance

    CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Maintenance CONDENSATE DRIP TRAYS AND DRAINS Drain lines should be checked to ensure that they are unobstructed and free draining. Drain traps should be checked that they are fully primed and functioning correctly. Drain trays should be checked to ensure they are free from debris.
  • Page 17 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Maintenance (Cont’d.) FANS Inspection of the fan assemblies (comprising the impellor and the motor) should be undertaken to ascertain whether any overheating of the motor is occurring, and to check that the fan impeller is free running and has not sustained any damage.
  • Page 18 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL Maintenance (Cont’d.) CONTROLS, PCBS AND WIRIN The controls and electrical connections should be checked regularly. The mains power supply connection should be visually checked. If there is any evidence whatsoever of damage or deterioration of the power supply connection, then the unit must not be put back into service until the supply con- nection has been replaced by suitably qualified personnel.
  • Page 19 CLIFC FIXED - INSTALLATION, OPERATION AND MAINTENANCE MANUAL THIS PAGE INTENTIONALLY LEFT BLANK CLIMA-FLEX...
  • Page 20 CLIFC - Fan & Coil Fixed Horizontal Av. Central No. 285, Parque Logístico Deleg. La Pila, San Luis Potosí, C.P. 78422 More info (444) 161.50.43 info@clima-flex.com Lada sin costo 01 800 890 59 17...

Table of Contents