NOTE:
• The [LIGHT MODE] can be changed by using the menu.
Select [SETUP] → [INSTALLATION(1)] → [LIGHT MODE] → [LIGHT MODE].
• The light module hours used can be checked in [USAGE TIME] on the menu. Select [INFO.] → [USAGE TIME].
• After a lapse of 1 minute from when the projector displays a blue, black or logo screen, [LIGHT MODE] will automatically switch
to [ECO].
• This projector equips the sensor to detect atmospheric pressure and temperature and the projector controls the power based on
the detected values. When the projector is used in high altitude and high temperature, the light source brightness becomes lower
regardless of the setting for LIGHT MODE. This is called "Forced ECO MODE". Please refer the below table for the conditions and
output power in Forced ECO MODE.
Altitudes
1600–3000 m
(5500–10000 ft)
1200–1600 m
(4000–5500 ft)
0–1200 m
(0–4000 ft)
• When the projector is in the Forced LIGHT MODE, the picture brightness decreases slightly and the TEMP. indicator lights orange.
At the same time the Thermometer symbol [ ] is displayed at the bottom of the screen.
When the projector comes back to normal temperature, the Forced ECO MODE is cancelled and the [LIGHT MODE] returns to
[NORMAL] mode. When the atmospheric pressure sensor detects height over 1200 m, the HIGH symbol [ ] will be displayed
at the bottom of the screen.
5–25°C
26–30°C
(41–77°F)
(78–86°F)
100%
100%
40
Atmospheric temperature
31–35°C
(87–95°F)
90%
80%
90%
100%
3. Convenient Features
36–40°C
(96–104°F)
70%
80%
80%