Rs232 Communication Commands; System Commands - Kensence KX-HDMI-44 User Manual

4k 4x4 hdmi2.0 matrix switcher
Table of Contents

Advertisement

reliable RS232 control.
Baud rate: 9600

6.3 RS232 Communication Commands

1) "[", "]" in the commands are for easy recognition only and not necessary in real
operations. Other symbols including ".", ",", "/", "%", ";", "^". are parts of the
commands.
2) Feedbacks listed in the column "Feedback Example" are only for reference,
feedbacks may vary according to different operations.
3) Dial the EDID switcher to "1111" before sending commands pertaining to software
EDID management (with grey background).

6.3.1 System Commands

Command
/*Type;
/^Version;
Demo.
Undo.
PWON.
PWOFF.
STANDBY.
%9962.
%9964.
%0911.
Data bit: 8
Function
Query the model.
Query the version of firmware
Switch to the "demo" mode, convert
input and output in turn like1B1,
1B2, ...4B3, 4B4, 1B1... and so
on .The switching interval is 2 seconds.
To cancel the current operation.
Work in normal mode.
Enter into standby mode, send the
"PWON." to start.
Enter into standby mode, press other
buttons or send other commands to
start.)
Query the power status
Query the IP address.
Reset to factory default.
4K 4x4 HDMI2.0 Matrix Switcher
Stop bit: 1
10
Parity bit: none
Feedback Example
XXXXX
VX.X.X
Demo Mode
AV:01->01
AV:01->02
AV:01->03
AV:01->04
AV:02->01
...
Normal Mode
Undo Ok!
PWON
PWOFF
STANDBY
STANDBY/PWOFF/
PWON
IP:XXX.XXX.X.XXX
Factory Default