Omron K3HB-R Manual page 12

Digital indicators
Hide thumbs Also See for K3HB-R:
Table of Contents

Advertisement

■ Characteristics
Display range
Measurement accuracy
(at 23±5 ° C)
Measurement range
Input signals
Connectable sensors
Comparative output response
time (transistor output)
Linear output response time
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of
Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
protection
Rear case
Terminals
Memory protection
Applicable standards
EMC
12
Timer Interval Indicator
− 19,999 to 99,999
±0.08% rgd ±1 digit (for voltage pulse/open collector sensors)
Functions F1, F3, and F4:10 ms to 3,200 s
Function F2:
20 ms to 3,200 s
Functions F5 and F6:
0 to 4 gigacounts
• No-voltage contact (30 Hz max. with ON/OFF pulse width of 15 ms min.)
Mode
Input frequency
range
9 µ s min.
F1 to F4 0 to 50 kHz
16 µ s min.
F5, F6
0 to 30 kHz
Mode
Input frequency
range
9 µ s min.
F1 to F4 0 to 50 kHz
16 µ s min.
F5, F6
0 to 30 kHz
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current:
Must have a switching capacity of 20 mA or higher.
Must be able to properly switch load currents of 5 mA or less.
2 ms max. (time until the comparative output is made when there is a forced sudden change in the input signal
from 15% to 95% or 95% to 15%)
10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the
input signal from 15% to 95% or 95% to 15%)
20 M Ω min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
± 1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns)
24 VAC/VDC models:
± 1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns)
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
2
2
150 m/s
(100 m/s
for relay outputs) 3 times each in 3 axes, 6 directions
Approx. 300 g (Base Unit only)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
CISPR 11 Group 1, Class A: CISPRL16-1/-2
Terminal interference voltage
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4GHz to 2 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0 ° /180 °, 100% (rated voltage)
K3HB-P
ON/OFF
ON voltage
OFF voltage
pulse width
− 30 to 2 V
4.5 to 30 V
ON/OFF
Note: The Digital Time Interval Meter
pulse width
will malfunction if a pulse greater
than the input frequency range is
input. SYSERR may appear on
the display.
2
, 10 sweeps of 5 min each in X, Y, and Z directions
•Voltage pulse
Input
impedance
10 k Ω
•Open collector

Hide quick links:

Advertisement

Table of Contents
loading