Features
Many I/O Variations for Discrimination, Control, and Information Applications
Digital Indicators are used in a wide variety of applications, from an electronic measurement value display or equipment/device operating status
display to a host communications interface in monitoring and control systems. OMRON provides a complete lineup for a variety of input and control
output applications to meet all your application requirements.
Relay Outputs
H and L: SPDT
C1
C2
H/OUT4
C3
C4
L/OUT2
C5
C6
Communications
Output
RS-232 or RS-485
RS-232C or
RS-485
Computer
Select a Comparative Output Pattern to
Suit the Discrimination or Control
Application
• The output pattern for comparative outputs can be selected. In
addition to high/low comparison with set values, output based on
level changes is also possible. (Use the type of output pattern
appropriate for the application.)
Standard Outputs
Measurement
Comparative
value
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
ON
Output HH
OFF
Output H
Output PASS
Output L
Output LL
Measurement
Zone Outputs
Comparative
value
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
ON
Output HH
OFF
Output H
Output PASS
Output L
Output LL
Note: The HH, H, L or LL outputs must be set in that order for the zone
outputs to output correctly.
(This is because the comparative set values and outputs for
standard and level outputs are in a 1-to-1 relationship, whereas
the meaning of zone outputs depends on the settings of all the
comparative set values.)
2
Digital Indicators
HH, H, L, and LL: SPST-NO
C1
HH/OUT5
C2
H/OUT4
C3
COM
C4
L/OUT2
C5
LL/OUT1
C6
COM
Linear Output
Voltage Output or Current Output
0 to 20 mA DC/
4 to 20 mA DC
or
0 to 5 VDC/
1 to 5 VDC/
0 to 10 VDC
Level Outputs
Comparative
set value HH
Higher
Comparative
set value H
Comparative
set value L
Lower
Comparative
set value LL
Output HH
Output H
Output PASS
Output L
Output LL
Higher
Lower
K3HB Series (Pulse Input Series)
PASS: SPDT
B1
PASS/OUT3
B2
B3
B4
N/C
+
(CPB)
B5
Sensor
10 VDC 100 mA
power
(CPA)
supply
B6
12 VDC 80 mA
DeviceNet
Lineup Includes DeviceNet Models
Enabling High-speed Data
Communications with PLCs without
Special Programming
• DeviceNet compliance enables high-speed data transmission by
allocating setting and monitoring parameters in the I/O memory of
the PLC. This capability greatly reduces labor spent in developing
Measurement
value
communications programs.
Higher
Lower
ON
OFF
P
Zero
P
Zero
Transistor Outputs
NPN or PNP
C1
HH/OUT5
C2
H/OUT4
C3
PASS/OUT3
C4
L/OUT2
C5
LL/OUT1
C6
COM
BCD Output
NPN Open Collector
DeviceNet
Master
H
K3HB
Digital Indicators
H
PNP
NPN
Ethernet
DeviceNet
Configurator