Technical Data; Specifications - Rinnai RLX94i Installation And Operation Manual

Direct vent tankless water heater for indoor/outdoor applications only
Table of Contents

Advertisement

Available languages

Available languages

Specifications

Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Hot water capacity (Min - Max) *
Temperature Setting (no controller)
Maximum Temp Setting (residential)
Maximum Temp Setting
(MCC-91 controller)
Minimum Temperature Setting
Weight
Energy Factor
Noise level
Normal
Standby
Anti-frost Protection
Electrical Data
Max Current
Fuse
By-Pass Control
Natural Gas
Gas Supply
Pressure
Propane
Type of Appliance
Connections
Ignition System
Electric Connections
Water Temperature Control
Water Supply Pressure
Maximum Water Supply Pressure
Temperature Control Cable
Certified for installation in
manufactured (mobile) homes
Complies with South Coast Air Quality
Management District 14 ng/J or 20
ppm NOx emission levels
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Minimum activation flow is 0.4 GPM (1.5 L/min).
Our products are continually being updated and improved; therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the
purpose of input adjustment.

Technical Data

RL75i
RLX94i
180,000
192,000
0.26 - 7.5 GPM
0.26 - 9.8 GPM
(1.0 - 28.5 L/min)
(1.0 - 37.0 L/min)
Selectable at 120° F (49° C) or at 140° F (60° C)
160° F (71° C)
185° F (85° C)
45.6 lb (20.7 kg)
46.3 lb (21.0 kg)
76 W
97 W
120 W
With recirculation pump: 8 A (exact value depends on the pump)
Fixed
Electronic
Direct Vent, Tankless, Temperature controlled continuous flow gas hot water system
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Temperature Controller: DC 12 Volts (Digital)
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
Non-Polarized Two Core Cable (Minimum 22 AWG)
Yes
Yes
VC Series Manual
RL94i
10,300
199,000
0.26 - 9.8 GPM
(1.0 - 37.0 L/min)
120° F (49° C) or 140° F (60° C)
185° F (85° C)
98° F (37° C)
46.3 lb (21.0 kg)
0.82
49 dB (excluding start up or shutdown)
97 W
2 W
Without recirculation pump: 4 A
10 A
Electronic
4.0 - 10.5 inch W.C.
8.0 - 13.5 inch W.C.
Direct Electronic Ignition
Appliance: AC 120 Volts, 60Hz.
Simulation Feedforward and Feedback
150 PSI
Yes
No
RL75e
RL94e
180,000
199,000
0.26 - 7.5 GPM
0.26 - 9.8 GPM
(1.0 - 28.5 L/min)
(1.0 - 37.0 L/min)
160° F (71° C)
185° F (85° C)
43.6 lb (19.8 kg)
44.3 lb (20.1 kg)
57 W
65 W
104 W
Fixed
Electronic
Yes
Yes
25