3.7TECHNICALDATA
InfinityModel
Installation
Flue system
Temperature range with water controller
Tempearature range with push buttons
Ignition
Gas consumption
Natural Gas: Input
LPG Input
Out put
Country of destination
Gas type and pressure
Type
Max water flowrate
Min operation flowrate
Min operating water pressure (Pmin)
Water pressure (@nom/max flowrate-max) - (Pw)
Power supply
Electric consumption (remote/standby+remote/antifrost)
Noise level
Weight
IP protection
Anti-freeze temperature protection
1
minimum water flowrate may vary depending on the temperature setting and the inlet water temperature.
2
when protected from direct wind exposure.
REU-AM2024WD-SA
External, outdoor
Direct forced exhaust
37-46, 48, 50, 55, 60, 65
40, 42, 50, 55, 60, 65
Direct electronic ignition
156
156 (3,1kg/h)
126,1
South Africa
Natural gas – 2,0 kPa,
LP
gas – 2,8 kPa
D(Outdoor installation)
24
ON=1,5 / OFF=1,0
0,1
1,0/1,4-10
230V/50Hz
55/2/68
54
14,5
IPx5D
-20
REU-AM2626WD-SA
199
199 (4,0kg/h)
161,1
26
1
56
15,5
2
Unit
-
°C
°C
-
-
MJ/h
MJ/h
MJ/h
-
-
-
L/min
L/min
bar
bar
-
W
dB (A)
kg
-
°C