Rinnai RLX94i Installation And Operation Manual page 35

Direct vent tankless water heater for indoor/outdoor applications only
Table of Contents

Advertisement

Available languages

Available languages

Temperatures Available with a Controller
The water heater can deliver water at only one temperature setting at a time. The available temperatures are
provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the "On/Off" button
for 5 seconds while the water heater is OFF.
RL75i, RL75e
98 100 102 104 106 108 110 115 120
RL94i, RLX94i,
RL94e
Celsius °C
37
*
Temperature settings from 125-140 °F (52-60 °C) are available by setting switch 6 to ON in the SW1 Dip
switch (tan switches). These models have a default maximum temperature of 120° F (49° C) and an option
(switch 6) to increase the maximum temperature to 140 °F (60 °C).
** These settings require the MCC-91-2 controller. When the MCC-91-2 controller is connected, these higher
temperatures are available on all controller models in the system. Use of an MCC-91-2 controller in a
residential dwelling will reduce the warranty coverage to that of a commercial warranty application.
WARNING
These temperatures are suggestions only:
Alternate Temperature Settings
A different range of temperature settings is available by setting switches 2 and 3 of the SW2 dip switch (white
switches) to ON. The table below shows the settings available with the MC-91-2 and MCC-91-2 controller.
WARNING
RL75i, RL75e
RL94i, RLX94i, RL94e
Celsius °C
Temperature Settings Available (Fahrenheit °F)
38
39
40
41
DO NOT adjust the other switches unless specifically instructed to do so.
MC-91-1, MCC-91-1, MC-100V-1, and BC-100V-1 controllers are not compatible with
Alternate Temperature Settings. Alternate Temperature Settings are for commercial
applications only.
DO NOT use the MC-91-1, MCC-91-1, MC-100V-1, or BC-100V-1 controllers when dip
switches 2 and 3 (white switches) are in the ON position.
Alternate Temperature Settings Available (Fahrenheit °F)
110 115 120 125 130 135 140 145 150 155 160
43
46
49
52
MC-91-2
125
42
43
46
49
Kitchen
120 °F (49° C)
Shower
98 - 110 °F (37 - 43 °C)
Bath Fill 102 - 110 °F (39 - 43 °C)
54
57
60
63
MCC-91-2
VC Series Manual
130
135
140
150
*
*
*
*
52
54
57
60
165 170 175 180 185
66
68
71
74
160
**
**
185**
66
71
85
77
79
82
85
35