Rinnai RL75i Installation And Operation Manual

Rinnai RL75i Installation And Operation Manual

Direct vent tankless water heater
Table of Contents

Advertisement

FOR INDOOR APPLICATIONS ONLY
RL75i ..................... REU-VC2528FFUD-US
RL94i ..................... REU-VC2837FFUD-US
FOR OUTDOOR APPLICATIONS ONLY
RL75e .................... REU-VC2528WD-US
RL94e .................... REU-VC2837WD-US
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
This manual provides information on the installation, operation, and maintenance of the water heater. For proper
operation and safety, it is important to follow the instructions and adhere to the safety precautions.
A licensed professional must install the water heater according to the exact instructions on pages 4-30.
The consumer must read the entire manual to properly operate the water heater and to have regular maintenance
performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a licensed professional.
This entire manual must be left for the consumer. The consumer must read and
refer to this manual for proper operation and to maintain the water heater.
REU-VC2528FFUD(A)-US
REU-VC2528WD(A)-US
ANS Z21.10.3 ● CSA 4.3
If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Direct Vent Tankless Water Heater
Installation and Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RL75i

  • Page 1 Direct Vent Tankless Water Heater Installation and Operation Manual FOR INDOOR APPLICATIONS ONLY RL75i ..... REU-VC2528FFUD-US REU-VC2528FFUD(A)-US RL94i ..... REU-VC2837FFUD-US FOR OUTDOOR APPLICATIONS ONLY RL75e ....REU-VC2528WD-US REU-VC2528WD(A)-US RL94e ....REU-VC2837WD-US ANS Z21.10.3 ● CSA 4.3 READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
  • Page 2: Table Of Contents

    If you have any questions or feel that the manual is incomplete contact Rinnai at 1-800-621-9419 Important Safety Information Safety Definitions This is the safety alert symbol.
  • Page 3: Safety Behaviors And Practices For The Consumer And Installer

    Safety Behaviors and Practices for the Consumer and Installer WARNING   Before operating, smell all around the appliance Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not area for gas.
  • Page 4: Installation Instructions

    A licensed professional must install the appliance, DO NOT inspect it, and leak test it before use. The warranty  Do not install the RL75i or the RL94i outdoors. will be voided due to improper installation.  Do not install the RL75e or the RL94e indoors.
  • Page 5: Prepare For Installation

    Prepare for installation  The appliance must be isolated from the gas supply Parts included piping system by closing its individual manual shutoff valve during any pressure testing of the gas  Tankless water heater supply piping system at test pressures equal to or ...
  • Page 6: Determine Installation Location

     Install as far away as possible from air inlet Rinnai provides a “Scale Control System” that offers vents. Corrosive fumes may be released through superior lime scale prevention and corrosion control...
  • Page 7: Vent Termination Clearances

    Vent Termination Clearances For indoor models, you must install a vent termination to bring in combustion air and expel exhaust. TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED AIR SUPPLY INLET CLOSED OPERABLE VENT TERMINAL...
  • Page 8 Additional clearances - RL75i, RL94i 60" (1.52 m) Check on whether local codes supersede these clearances. between  terminals at Avoid termination locations near a dryer vent. different levels  Avoid termination locations near commercial cooking exhaust.  You must install a vent termination at least 12 inches from the ground.
  • Page 9: Additional Clearances

    Additional clearances RL75e, RL94e Local codes supersede these clearances.  Avoid termination locations near a dryer vent.  Avoid termination locations near commercial cooking exhaust. (0.91 m) to ventilated or unventilated 36" soffit or eve vent; or to a deck or porch 12"...
  • Page 10 Unit clearances Indoor models: RL75i, RL94i Outdoor models: RL75e, RL94e to Non- to Non- to Combustibles to Combustibles Combustibles Combustibles inches (mm) inches (mm) inches (mm) inches (mm) Top of Heater 6 * (152) 2 *(51) Top of Heater 12 (305)
  • Page 11: Maximum Vent Length

    Maximum vent length Freeze Protection (indoor models only) Make sure that in case of freezing weather that the water heater and its water lines are protected to 1. Determine the number of 90 degree elbows in prevent freezing. Damage due to freezing is not the vent system.
  • Page 12: Checklist To Determine Installation Location

    Mount to Wall Checklist to Determine Installation Location □ The water heater is not exposed to corrosive compounds in the air. □ The water heater location complies with the wall installation clearances. brackets □ For indoor models, the planned venting will not exceed the maximum length for the number of elbows used.
  • Page 13: Installation Of Venting (Indoor Models Only)

    You must use vent components that are If it becomes necessary to access an enclosed vent certified and listed with the water heater model. system for service or repairs, Rinnai is not responsible  The vent system must vent directly to the outside for any costs or difficulties in accessing the vent of the building and use outside air for combustion.
  • Page 14: Flue Installation

    Flue Installation (indoor models only) Install the venting termination according to the diagrams and instructions below. Horizontal Termination without using the Condensate Collector WARNING * The condensate collector must be used in horizontal terminations if a vertical rise in If the condensate collector is not used, the drain pipe the vent system exceeds 5ft.
  • Page 15: Condensate (Indoor Models Only)

    Condensate (indoor models only) INFORMATION Condensate formation can occur in high efficiency direct vent appliances. Without proper drainage  A condensate trap is available, P/N 222053. condensate will damage the heat exchanger.  Regions of cold climate will create more To prevent condensate damage follow these condensate in the vent system.
  • Page 16: Installation Of Plumbing

    Isolation valves are included with this water heater.  Do not place any other type valve or shut off Rinnai strongly recommends the installation of device between the relief valve and the water isolation valves on the cold and hot water lines heater.
  • Page 17 Isolation Valves and Pressure Relief Valve The isolation valves provide the ability to isolate the water heater from the structure’s plumbing and allow quick access to flush the heat exchanger. Check with local codes to determine if a pressure and temperature relief valve is required.
  • Page 18: Piping Diagram For Basic Installation

    Piping Diagram for Basic Installation Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) 3/4" Hot Water Supply Line For Building Fixtures This is not an engineered drawing.
  • Page 19: Checklist For Plumbing

    □ Check for proper water pressure to the water corrosive.) heater. Minimum water pressure is 50 psi. Rinnai  Use approved connectors to connect the unit to recommends 60-80 psi for maximum the gas line.
  • Page 20  Any compound used on the threaded joint of the Pipe Sizing Table - Natural Gas gas piping shall be a type which resists the action Schedule 40 Metallic Pipe of liquefied petroleum gas (propane / LPG). Inlet Pressure: less than 2 psi (55 inches W.C.) ...
  • Page 21: Connect Electricity

    Connect Electricity Adjust for High Altitude WARNING On the SW1 DIP switch (tan switches), set switches 2 and 3 to the values shown in table below for your Do not use an extension cord or an adapter plug with altitude. The default setting for the appliance is 0- this appliance.
  • Page 22: Installation Of Temperature Controller

    Controllers cannot be wired in series. connections inside the unit. Do not connect the temperature controller to the Maximum 4 Controllers Rinnai 120VAC terminals provided for the optional solenoid Water drain valves. Heater Indoor models have their controller built into the front panel.
  • Page 23: Mounting The Controller

    Mounting the controller 1. Make three holes in the wall as shown. Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2. Run the cable between the controller and the water heater or the controller and another controller. 3.
  • Page 24: Final Checklist

    □ Final Checklist A manual gas control valve has been placed in the gas line to the water heater. □ The water heater is not subject to corrosive □ Check the gas lines and connections for leaks. compounds in the air. □...
  • Page 25: Technical Data

    Technical Data Specifications RL75i RL94i RL75e RL94e Minimum Gas Consumption Btu/h 10,300 Maximum Gas Consumption Btu/h 180,000 199,000 180,000 199,000 0.26 - 7.5 GPM 0.26 - 9.8 GPM 0.26 - 7.5 GPM 0.26 - 9.8 GPM Hot water capacity (Min - Max) * (1.0 - 28.5 L/min)
  • Page 26: Dimensions

    Dimensions Inches (millimeters) RL75i, RL94i 9.27 (235.5) 14.04 (356.6) 0.4~1.8(10~45) Variable 5.05 (128.1) DIMENSION Inches (mm) DIMENSION Inches (mm) A (GAS) 1.31 (33.2) 4.33 (110) A (COLD) 1.93 (49) 2.89 (73.3) A (HOT) 1.35 (34.4) 1.85 (47) 4.21 (106.9) 3.44 (87.3) 1.17 (29.8)
  • Page 27: Pressure Drop And Water Flow Curves

    Pressure Drop Curve 60.00 RL75 RL94 55.00 50.00 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 Water Flow (gpm) Water Flow Curve RL94 RL75 delta T - Temperature Rise (° F) VC Series Manual...
  • Page 28: Ladder Diagram

    Ladder Diagram VC Series Manual...
  • Page 29: Recirculation Mode

    Recirculation Mode recommendations. The Rinnai water heater has the ability to control a recirculation pump. Two modes are available, 4. Adjust the dip switch by moving the 4th switch in Economy and Comfort, which recirculate the water in the whie set of switches (SW2) to ON.
  • Page 30 Recirculation Mode Sequence of Operation Typical Pump ON Intervals* Rinnai DIP switches (SW2 - white switches, #4, #8) should be (minutes) Temperature set correctly for recirculation and mode. The Rinnai Setting water heater should be turned on. Economy Comfort Mode Mode °F...
  • Page 31: Operation Instructions

    RL94e ....REU-VC2837WD-US Important Facts about your Water Heater Thank you for purchasing a Rinnai Tankless Water Heater. For proper operation and safety, it is important to follow the instructions and adhere to the safety precautions. Read all of the instructions and the warranty thoroughly before operating this water heater. Keep this manual in a safe place.
  • Page 32: Consumer Operation Guidelines For The Safe Operation Of Your Water Heater

    Consumer Operation Guidelines for the Safe Operation of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 33: How To Use The Temperature Controller

    Rinnai provides a “Scale Control System” that offers superior lime scale prevention and  Keep the area around the appliance clear and free...
  • Page 34: How To Set The Temperature

    How to Set the Temperature This water heater requires a minimum flow rate to operate. This rate can be found on the specification page in this manual. In some cases when you are not getting hot water or if the water alternates between hot and cold, it is due to the water flow being below or close to the minimum flow rate.
  • Page 35 To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” button for 5 seconds while the water heater is OFF. Temperature Settings Available (Fahrenheit °F) RL75i, RL75e 98 100 102 104 106 108 110 115 120 RL94i, RL94e 185** Celsius °C...
  • Page 36: Temperature Options Without A Temperature Controller

    Temperature Options Without a Temperature Controller The default temperature setting for this appliance installed without a temperature controller is 120° F (49° C). If desired, the temperature setting can be changed to 140° F (60° C) by adjustment of a switch. In the SW1 Dip switch (tan switches), set switch 5 to ON to obtain 140°...
  • Page 37: Diagnostic Codes And Remedies

    Diagnostic Codes and Remedies WARNING Some of the checks below should be done by a licensed professional. Consumers should never attempt any action that they are not qualified to perform. Code Definition Remedy Power interruption during Bath Fill (Water will not flow when Turn off all hot water taps.
  • Page 38 LC2,…) Off button on the temperature controller 5 times. Repeated LC codes will eventually lockout “LC”) the water heater. Please call Rinnai technical department. Maintenance has been Indicates a licensed professional performed maintenance or corrected an issue. performed Clean inlet water supply filter.
  • Page 39: Required Maintenance

    Required Maintenance The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be per- formed by a licensed professional. The licensed professional must verify proper operation after servicing. WARNING To protect yourself from harm, before performing maintenance: ...
  • Page 40: Pressure Relief Valve

    WARNING Freeze Protection Make sure that in case of freezing weather that the Testing the pressure relief valve should only be water heater and its water lines are adequately performed by a licensed professional. Scalding hot protected to prevent freezing. Damage due to water may be released under pressure.
  • Page 41: Flushing The Heat Exchanger

    An LC0~LC9 or “00” diagnostic code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. Rinnai strongly recommends installation of isolation valves to allow for flushing of the heat exchanger.
  • Page 42: Manual Draining Of The Water Heater

    Manual Draining of the Water Heater WARNING To avoid burns, wait until the equipment cools down before draining the water. The water in the appliance will remain hot after it is turned off. If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.
  • Page 43: State Regulations

    State Regulations NOTICE BEFORE INSTALLATION This direct-vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 44: Parts List

    Replacement Parts The Technical Sheet which is located inside the front cover of the water heater contains a complete illustrated parts list. Tech Sheet Gas Control Assembly Electrode / Flame Rod Item No. Gas Control Assembly Electrode / Flame Rod Kit 116, 117 Fan Assembly / Motor Heat Exchanger...
  • Page 45: Consumer Warranty

    48 months (a total of 60 months labor coverage from date of purchase), when used in a residential hot water application, if the product is registered within 30 days of purchase at www.rinnai.us/ product-registration or by calling 1-866-RINNAI-1 (746-6241), except registration is not required in California and Quebec.
  • Page 46 A timer added to a standard recirculating pump is not considered as on-demand. [2] Period of coverage is reduced to 5 years from date of purchase if the Rinnai water heater temperature setting exceeds 160° F (71°C).
  • Page 47: Vc Series Manual

    Limitation on warranties No one is authorized to make any other warranties on behalf of Rinnai America Corporation. Except as expressly provided herein, there are no other warranties, expressed or implied, including, but not limited to warranties of merchantability or fitness for a particular purpose, which extend beyond the description of the warranty herein.
  • Page 48: French Version

    Chauffe-eau d’intérieur sans réservoir à ventilation directe POUR LES APPLICATIONS INTÉRIEURES SEULEMENT Manuel d'installation et RL75i ..... REU-VC2528FFUD-US d'utilisation REU-VC2528FFUD(A)-US RL94i ..... REU-VC2837FFUD-US POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT RL75e ....REU-VC2528WD-US REU-VC2528WD(A)-US RL94e ....REU-VC2837WD-US ANS Z21.10.3 ● CSA 4.3 LIRE TOUTES LES INSTRUCTIONS SOIGNEUSEMENT AVANT D’INSTALLER OU D’EXPLOITATION DE CETTE...
  • Page 49 Nous allons cependant continuer à vous contacter avec les informations pertinentes pour le produit vous inscrit ou vous rendre compte avec nous. Si vous avez des questions ou se sentent que le manuel est incomplète, veuillez communiquer avec Rinnai au 1-800-621-9419.
  • Page 50: Les Pratiques Et Les Comportements De Sécurité Pour Les Consommateurs Et Les Installateurs

    Les pratiques et les comportements de sécurité pour les consommateurs et les installateurs AVERTISSEMENT   Utilisez seulement votre main pour pousser ou Avant d'exploitation, une odeur tout autour de la tourner le bouton de contrôle des gaz. Ne jamais zone de l'appliance pour le gaz.
  • Page 51: Installation D'instructions

    Un professionnel autorisé doit installer l'appareil, NE FAITES PAS inspecter et fuite de le tester avant de l'utiliser. La  Le RL75i et RL94i n'est pas prévu pour une garantie va être annulée en raison de la mauvaise installation à l'extérieur. installation.
  • Page 52: Préparez-Vous À L'installation

    Préparez-vous à l'installation  L'appareil et sa vanne de gaz doivent être Pièces incluses débranchés de la conduite d'alimentation en gaz  Chauffe-eau sans Réservoir durant les essais du système en pression dépassant 1/2 psi (3.5 kPa ou 13,84 pouces de hauteur de ...
  • Page 53: Déterminez L'endroit D'installation

    Installez le chauffe-eau aussi loin que possible des par l'eau dure définie à haute température. hottes de ventilation d'échappement. Un kit de traitement de l'eau est disponible depuis Rinnai. Ce kit  Installez aussi loin que possible des bouches d'air fournit un contrôle de la prévention et à...
  • Page 54 Espacements pour terminaison de cheminée (ANS Z21.10.3, CSA 4.3) Vous devez installer une fin de vent à TERMINATION DÉTAIL D'ANGLE INSIDE Terminaison INTÉRIEUR COR NER DETAIL apporter dans l'air de combustion et d'expulser des gaz d'échappement. Clearance in Dédouanement en Ref.
  • Page 55 (0.91 m) à évent  terminaux au soffite ou eve ventilé RL75i, RL94i: Vous devez installer une résiliation de vent même niveau au moins 12 pouces du sol ou non aérée ; ou à un 36" pont ou un porche 12"...
  • Page 56 Dégagements d'unité Vers le haut Vers le haut Sur le côté Sur le côté Vers l'avant Vers l'avant Vers le sol Vers le sol Modèles d'intérieur: RL75i, RL94i Modèles extérieurs: RL75e, RL94e Jusqu'à Jusqu'à Jusqu'à Jusqu'à matières matières matières matières...
  • Page 57 Longueur maximum de ventilation Protection de gel 1. Déterminez le nombre de coudes à 90° dans le Assurez-vous que dans le cas de congélation météo système de ventilation (deux coudes à 45° que le chauffe-eau et ses lignes de l'eau sont protégés comptent pour un coude à...
  • Page 58: Liste De Vérification Pour Déterminez

    Bâti à murer Liste de vérification pour déterminer l'endroit d’installation □ Le chauffage de l'eau n'est pas corrosifs composés dans l'air. □ L'emplacement de chauffage de l'eau est parenthèses conforme avec les dégagements. d'installation de □ (Modèles d'intérieur) La ventilation prévue ne dépassera pas la longueur maximale pour le nombre de coudes utilisé.
  • Page 59: Installation De La Mise À L'air Libre (Modèles D'intérieur)

    S'il devient nécessaire d'accéder à un système d'évacuation quatre pieds et tous les évents verticale s'exécute fermée pour le service ou les réparations, Rinnai n'est pas chaque six pieds ou conformément aux codes responsable des frais ou des difficultés à accéder au locaux.
  • Page 60 Installation de conduit de cheminée (modèles d'intérieur) Résiliation horizontale sans utiliser le collecteur de condensat * Un collecteur de condensat est requis sur les AVERTISSEMENT terminaisons horizontales si une élévation verticale dans le système de ventilation Si un collecteur de condensat n'est pas utilisé, le tuyau dépasse 5' (1,5 m).
  • Page 61: Condensat (Modèles D'intérieur)

    Condensat (modèles d'intérieur) L’INFORMATION La formation de condensat peut arriver même sur les appareils à ventilation directe de haute performance.  Un collecteur de condensat intégré. Pour éviter que le condensat n'endommage, suivez  Dans les régions à climat froid il se produira plus ces instructions : de condensat dans le système de ventilation.
  • Page 62: Installation De La Tuyauterie

    Elle doit permettre un Vannes d'isolement sont inclus dans cette chauffe-eau. drainage complet de la soupape et de la conduite. Rinnai recommande fortement l'installation de vannes  Ne pas placer toute autre soupape de type ou fermer d'isolement sur les lignes de l'eau chaude et froide.
  • Page 63 Installez Valve à Bille / Valve de dégagement de pression Les soupapes d'isolement offrent la possibilité d'isoler le chauffe-eau de la structure plomberie et de permettre un accès rapide à vider l'échangeur de chaleur. Vérifiez auprès des codes locaux pour déterminer si une soupape de pression et de température est nécessaire.
  • Page 64 Tuyauterie recommandée pour installation de base Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) Connexion de gaz en 3/4 po (19 mm)
  • Page 65: Liste De Vérification Pour Tuyauterie

    Utilisez toujours des connecteurs approuvés pour chauffage de l'eau. Pression d'eau minimum est raccorder l'unité sur la conduite de gaz. Purgez de 50 psi. Rinnai recommande de 60-80 psi pour toujours la conduite de gaz de tous débris éventuels des performances optimales.
  • Page 66  Tout composé utilisé sur la jonction filetée du tuyau Table - gaz naturel de gaz doit être d'un type qui résiste à l'action du gaz Tuyau métallique annexe 40 propane ou naturel. La pression Inlet : moins de 2 psi (55 pouces W.C.) ...
  • Page 67: Reliez L'électricité

    Reliez l'électricité Ajustez à l'haute altitude Définissez les valeurs indiquées dans le tableau ci- AVERTISSEMENT dessous pour votre altitude commutateurs 2 et 3 N'utilisent pas une rallonge ou un adaptateur (SW1, commutateurs fauve). Le paramètre par brancher avec cet appareil. défaut pour l'appliance est 0-2000 ft (0-610 m) avec les commutateurs no 2 et 3 dans la position OFF.
  • Page 68: Installation De Le Contrôleur De Température

    Installation de le contrôleur de Montage du contrôleur température 1. Faire trois trous dans le mur, comme le montre. AVERTISSEMENT Outline of Remote Désactiver le pouvoir. Ne pas tenter de connecter les securing screw contrôleurs de température avec le pouvoir. Bien que le contrôleur est un dispositif de basse tension, il y a 1-21/32"...
  • Page 69: Liste De Vérification Finale

    Liste de vérification finale □ Le chauffage de l'eau n'est pas corrosifs composés □ Veiller à ce qu'une soupape est installée avec une cote dans l'air. qui dépasse l'entrée de BTU du modèle de chauffage de l'eau. Se référer à la plaque de cotation sur le côté □...
  • Page 70: Diagramme En Escalier

    Diagramme en escalier NEUTRE PHASE 2837 MODÈLE SEULEMENT POMPE RELAIS 3 FUSIBLE 10 A CONTACT DE DÉTECTION DE GEL ANTI-FOUDRE RELAIS 2 ANTI-FOUDRE RELAIS 1 ALLUMAGE TERRE ALIMENTATION D'ÉNERGIE DE COMMUTATION 170 V CC 12,6 V 40 V CC 5 V CC 0-5 V CC DÉTECTEUR ÉLECTRO-...
  • Page 71: Instructions D'utilisation

    RL94e ....REU-VC2837WD-US Faits importants sur votre chauffe-eau Je vous remercie pour l'achat d'un chauffe-eau sans réservoir Rinnai. Pour le bon fonctionnement et la sécurité, il est important de suivre les instructions et de respecter les mesures de sécurité. Toutes les instructions et la garantie lire attentivement avant d'exploitation cette chauffe-eau. Gardez ce manuel en lieu sûr.
  • Page 72: Directives D'opérations Du Consommateur Pour Le Fonctionnement Sécuritaire De Votre Chauffe-Eau

    Directives d'opérations du consommateur pour le fonctionnement sécuritaire de votre chauffe-eau À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, il peut en résulter un départ d'incendie ou une explosion, causant dégâts matériels, blessures corporelles ou même mort.
  • Page 73: Comment Utiliser Le Contrôleur De Température

    Comment utiliser le contrôleur de température Dimensions (pouces): 3.5 W x 4.75 H x 0.75 D Le contrôleur de MC-91-2 est le contrôleur de température standard qui est fourni avec l'appareil de chauffage de l'eau. Sur les modèles de l'intérieurs, elle est intégrée dans le panneau avant. Le contrôleur de MCC-91-2 est pour des applications commerciales et hydroniques nécessitant des températures plus élevées.
  • Page 74: Comment Définir La Temperature

    Comment définir la température Cette chauffe eau nécessite un débit minimum à exploiter. Ce taux se trouvent sur la page de spécification dans ce manuel. Dans certains cas lorsque vous n'obtenez pas l'eau chaude ou si l'eau alterne entre le chaud et le froid, c'est en raison du débit de l'eau étant ci-dessous ou à...
  • Page 75 à l'eau froide. Pour modifier l'échelle de température de Celsius à Fahrenheit ou vice versa, appuyez et tenir le bouton « On/Off » pendant 5 secondes, tandis que le chauffe-eau est désactivée. Plages de température disponible (Fahrenheit °F) RL75i, RL75e 98 100 102 104 106 108 110 115 120 RL94i, RL94e 185** Celsius °C...
  • Page 76: Entretien Requis

    Entretien requis L'appareil doit être inspecté chaque année par un technicien qualifié. Réparations et entretien doivent être effectuées par un technicien qualifié. Le technicien de service doit vérifier le bon fonctionnement après entre- tien. AVERTISSEMENT Pour vous protéger contre les préjudices, avant d'effectuer la maintenance : ...
  • Page 77 Nettoyez le filtre à eau Protection de gel Nettoyez le filtre à eau inlet en fermant les soupapes Assurez-vous que dans le cas de congélation météo d'isolement (fermeture) entrée froide et d'eau que le chauffe-eau et ses lignes de l'eau sont chaude.
  • Page 78: Flushing L'échangeur De Chaleur

    Un « LC » ou « 00 » code de diagnostic indique l'unité commence à chaux et doit être vidangée. Échec de vider l'appliance va causer des dommages à l'échangeur de chaleur. Dommages causés par l'accumulation de chaux ne sont pas couvert par la garantie de l'unité. Rinnai recommande fortement l'installation de vannes d'isolement pour permettre de chasse de l'échangeur de chaleur.
  • Page 79: Drainage Manuel Du Chauffe-Eau

    Drainage Manuel du chauffe-eau Pour éviter de burns, attendre jusqu'à ce que l'équipement se refroidit avant le AVERTISSEMENT drainage de l'eau. L'eau de l'appliance restera chaud après qu'il est éteint. Si le chauffe-eau ne va être utilisée pendant une période de temps au gel possible, il est recommandé que l'eau à l'intérieur du chauffe-eau être drainé.
  • Page 80: Garantie Du Consommateur

    Rinnai produit standard garantie limitée, comme le prévoit le manuel d'instructions de fonctionne- ment qui est livré avec ce produit. De garantie est également disponible sur le site web de Rinnai à www.rinnai.us. APPLICATIONS RÉSIDENTIELLES: La période de garantie limitée sur la couverture du travail pour les modèles RL75 et RL94 chauffe-eau installé...
  • Page 81 Une minuterie ajoutée sur une pompe de recirculation standard n'est pas considérée comme donnant un système à la demande. Période de couverture est réduite à 5 ans à compter de la date d'achat, si le paramètre de température chauffe eau Rinnai dépasse 160° F (71° C).
  • Page 82 Limitation sur les garanties Personne n'est autorisé à apporter toute autre garantie au nom de Rinnai pour ce produit. Sauf pour ce qui est expressément communiqué ici, il n'y a aucune autre garantie, explicite ou implicite, y compris sans y être limité les garanties de valeur marchande ou d'adéquation à...
  • Page 83 VC Series Manual...
  • Page 84 • Up to 0.96 Energy Factor (EF) Applications • Internal or External Installation ® • ENERGY STAR qualified models • Pair up with the Rinnai Air Handler for efficient home heating Direct Vent Furnaces • High Efficiency • Vent Terminal A Included • Cool-to-the-touch Cabinet •...

This manual is also suitable for:

Rl94iRl75eRl94e

Table of Contents