Rinnai RL75i REU-VC2528FFUD-US Installation And Operation Manual

Rinnai RL75i REU-VC2528FFUD-US Installation And Operation Manual

Direct vent tankless water heater
Table of Contents

Advertisement

Available languages

Available languages

FOR INDOOR APPLICATIONS ONLY
RL75i .....................REU VC2528FFUD US
RL94i .....................REU VC2837FFUD US
FOR OUTDOOR APPLICATIONS ONLY
RL75e ....................REU VC2528WD US
RL94e ....................REU VC2837WD US
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
This manual provides informa on on the installa on, opera on, and maintenance of the water heater. For proper
opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.
A licensed professional must install the water heater according to the exact instruc ons on pages 4 30.
The consumer must read the en re manual to properly operate the water heater and to have regular maintenance
performed.
WARNING
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc ons.
If you cannot reach your gas supplier, call the fire department.
— Installa on and service must be performed by a licensed professional.
This en re manual must be le for the consumer. The consumer must read and
refer to this manual for proper opera on and to maintain the water heater.
REU VC2528FFUD(A) US
REU VC2528WD(A) US
ANS Z21.10.3
If the informa on in these instruc ons is not followed exactly, a fire or explosion
may result causing property damage, personal injury or death.
Direct Vent Tankless Water Heater
Installa on and Opera on Manual
CSA 4.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RL75i REU-VC2528FFUD-US and is the answer not in the manual?

Questions and answers

Marcie Trantham
May 2, 2025

I am unhappy with Plumbing firm whom installed our tankless water heater. How do, I maintain, our warranty. Can, I go to nother plumber ? Thx u

1 comments:
Mr. Anderson
May 17, 2025

To maintain the warranty for the Rinnai RL75i REU-VC2528FFUD-US tankless water heater, you must contact a licensed professional for any repairs. If you choose a different plumber, they must be licensed. Using an unlicensed person may result in denial of the warranty claim. Additionally, you must provide proof of purchase, either with a dated sales receipt or by registering the product within 30 days of purchase.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Rinnai RL75i REU-VC2528FFUD-US

  • Page 1 Direct Vent Tankless Water Heater Installa on and Opera on Manual FOR INDOOR APPLICATIONS ONLY RL75i .....REU VC2528FFUD US REU VC2528FFUD(A) US RL94i .....REU VC2837FFUD US FOR OUTDOOR APPLICATIONS ONLY RL75e ....REU VC2528WD US REU VC2528WD(A) US RL94e ....REU VC2837WD US ANS Z21.10.3 CSA 4.3 READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.
  • Page 2: Table Of Contents

    If you have any ques ons or feel that the manual is incomplete contact Rinnai at 1 800 621 9419 Important Safety Informa on Safety Defini ons...
  • Page 3: Safety Behaviors And Prac Ces For The Consumer And Installer

    Safety Behaviors and Prac ces for the Consumer and Installer WARNING Before opera ng, smell all around the appliance Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not area for gas.
  • Page 4: Installa On Instruc Ons

    Installa on Instruc ons Installer Qualifica ons General Instruc ons A licensed professional must install the appliance, DO NOT inspect it, and leak test it before use. The warranty Do not install the RL75i or the RL94i outdoors. will be voided due to improper installa on. Do not install the RL75e or the RL94e indoors.
  • Page 5: Prepare For Installa On

    Prepare for installa on The appliance must be isolated from the gas supply Parts included piping system by closing its individual manual shuto valve during any pressure tes ng of the gas Tankless water heater supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
  • Page 6: Determine Installa On Loca On

    Install as far away as possible from air inlet Rinnai provides a “Scale Control System” that o ers vents. Corrosive fumes may be released through superior lime scale preven on and corrosion control...
  • Page 7 Vent Termina on Clearances For indoor models, you must install a vent termina on to bring in combus on air and expel exhaust. TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED AIR SUPPLY INLET...
  • Page 8 Addi onal clearances RL75i, RL94i 60" (1.52 m) Check on whether local codes supersede these clearances. between terminals at Avoid termina on loca ons near a dryer vent. di erent levels Avoid termina on loca ons near commercial cooking exhaust. You must install a vent termina on at least 12 inches from the ground.
  • Page 9 Addi onal clearances RL75e, RL94e Local codes supersede these clearances. Avoid termina on loca ons near a dryer vent. Avoid termina on loca ons near commercial cooking exhaust. (0.91 m) to ven lated or unven lated 36" so t or eve vent; or to a deck or porch 12"...
  • Page 10 Unit clearances to top to top to side to side to front to front to ground/bottom to ground/bottom Indoor models: RL75i, RL94i Outdoor models: RL75e, RL94e to Non to Non to Combus bles to Combus bles Combus bles Combus bles inches (mm) inches (mm) inches (mm)
  • Page 11 Maximum vent length Freeze Protec on (indoor models only) Make sure that in case of freezing weather that the water heater and its water lines are protected to 1. Determine the number of 90 degree elbows in prevent freezing. Damage due to freezing is not the vent system.
  • Page 12: Checklist To Determine Installa On Loca On

    Mount to Wall Checklist to Determine Installa on Loca on The water heater is not exposed to corrosive compounds in the air. The water heater loca on complies with the wall installa on clearances. brackets For indoor models, the planned ven ng will not exceed the maximum length for the number of elbows used.
  • Page 13: Installa On Of Ven Ng (Indoor Models Only)

    If it becomes necessary to access an enclosed vent cer fied and listed with the water heater model. system for service or repairs, Rinnai is not responsible The vent system must vent directly to the outside for any costs or di cul es in accessing the vent of the building and use outside air for combus on.
  • Page 14 Flue Installa on (indoor models only) Install the ven ng termina on according to the diagrams and instruc ons below. Horizontal Termina on without using the Condensate Collector WARNING * The condensate collector must be used in horizontal termina ons if a ver cal rise in If the condensate collector is not used, the drain pipe the vent system exceeds 5 .
  • Page 15: Condensate (Indoor Models Only)

    Condensate (indoor models only) INFORMATION Condensate forma on can occur in high e ciency direct vent appliances. Without proper drainage A condensate trap is available, P/N 222053. condensate will damage the heat exchanger. Regions of cold climate will create more To prevent condensate damage follow these condensate in the vent system.
  • Page 16: Installa On Of Plumbing

    Isola on valves are included with this water heater. Do not place any other type valve or shut o Rinnai strongly recommends the installa on of device between the relief valve and the water isola on valves on the cold and hot water lines heater.
  • Page 17 Isola on Valves and Pressure Relief Valve The isola on valves provide the ability to isolate the water heater from the structure’s plumbing and allow quick access to flush the heat exchanger. Check with local codes to determine if a pressure and temperature relief valve is required.
  • Page 18 Piping Diagram for Basic Installa on Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) 3/4" Hot Water Supply Line For Building Fixtures This is not an engineered drawing.
  • Page 19: Checklist For Plumbing

    Check for proper water pressure to the water corrosive.) heater. Minimum water pressure is 50 psi. Rinnai Use approved connectors to connect the unit to recommends 60 80 psi for maximum the gas line.
  • Page 20 Any compound used on the threaded joint of the Pipe Sizing Table Natural Gas gas piping shall be a type which resists the ac on Schedule 40 Metallic Pipe of liquefied petroleum gas (propane / LPG). Inlet Pressure: less than 2 psi (55 inches W.C.) The gas supply line shall be gas ght, sized, and so Pressure Drop: 0.3 inches W.C.
  • Page 21: Connect Electricity

    Connect Electricity Adjust for High Al tude WARNING On the SW1 DIP switch (tan switches), set switches 2 and 3 to the values shown in table below for your Do not use an extension cord or an adapter plug with al tude.
  • Page 22: Installa On Of Temperature Controller

    Controllers cannot be wired in series. connec ons inside the unit. Do not connect the temperature controller to the Maximum 4 Controllers Rinnai 120VAC terminals provided for the op onal solenoid Water drain valves. Heater Indoor models have their controller built into the front panel.
  • Page 23 Moun ng the controller 1. Make three holes in the wall as shown. Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2. Run the cable between the controller and the water heater or the controller and another controller.
  • Page 24: Final Checklist

    Final Checklist A manual gas control valve has been placed in the gas line to the water heater. The water heater is not subject to corrosive Check the gas lines and connec ons for leaks. compounds in the air. Confirm that the gas inlet pressure is within The water supply does not contain chemicals or limits.
  • Page 25: Technical Data

    Technical Data Specifica ons RL75i RL94i RL75e RL94e Minimum Gas Consump on Btu/h 10,300 Maximum Gas Consump on Btu/h 180,000 199,000 180,000 199,000 0.26 7.5 GPM 0.26 9.8 GPM 0.26 7.5 GPM 0.26 9.8 GPM Hot water capacity (Min Max) * (1.0 28.5 L/min) (1.0 37.0 L/min) (1.0 28.5 L/min)
  • Page 26: Dimensions

    Dimensions Inches (millimeters) RL75i, RL94i 9.27 (235.5) 14.04 (356.6) 0.4~1.8(10~45) Variable 5.05 (128.1) DIMENSION Inches (mm) DIMENSION Inches (mm) A (GAS) 1.31 (33.2) 4.33 (110) A (COLD) 1.93 (49) 2.89 (73.3) A (HOT) 1.35 (34.4) 1.85 (47) 4.21 (106.9) 3.44 (87.3) 1.17 (29.8) RL75e, RL94e 9.27 (235.5)
  • Page 27: Pressure Drop And Water Flow Curves

    Pressure Drop Curve RL75 RL94 Water Flow (gpm) Water Flow Curve RL94 RL75 delta T Temperature Rise (° F) VC Series Manual...
  • Page 28: Ladder Diagram

    Ladder Diagram VC Series Manual...
  • Page 29: Recircula On Mode

    Recircula on Mode recommenda ons. The Rinnai water heater has the ability to control a recircula on pump. Two modes are available, 4. Adjust the dip switch by moving the 4th switch in Economy and Comfort, which recirculate the water in the whie set of switches (SW2) to ON.
  • Page 30 Sequence of Opera on Typical Pump ON Intervals* Rinnai DIP switches (SW2 white switches, #4, #8) should be (minutes) Temperature set correctly for recircula on and mode. The Rinnai Se ng water heater should be turned on. Economy Comfort Mode Mode °F...
  • Page 31: Opera On Instruc Ons

    RL94e....REU VC2837WD US Important Facts about your Water Heater Thank you for purchasing a Rinnai Tankless Water Heater. For proper opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.
  • Page 32: Consumer Opera On Guidelines For The Safe Opera On Of Your Water Heater

    Consumer Opera on Guidelines for the Safe Opera on of your Water Heater FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instruc ons exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 33: How To Use The Temperature Controller

    floor. flushed regularly. Rinnai provides a “Scale Control System” that o ers superior lime scale preven on and Keep the area around the appliance clear and free...
  • Page 34: How To Set The Temperature

    How to Set the Temperature This water heater requires a minimum flow rate to operate. This rate can be found on the specifica on page in this manual. In some cases when you are not ge ng hot water or if the water alternates between hot and cold, it is due to the water flow being below or close to the minimum flow rate.
  • Page 35 Temperatures Available with a Controller The water heater can deliver water at only one temperature se ng at a me. The available temperatures are provided below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water. To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/O ”...
  • Page 36: Diagnos C Codes

    Temperature Op ons Without a Temperature Controller The default temperature se ng for this appliance installed without a temperature controller is 120° F (49° C). If desired, the temperature se ng can be changed to 140° F (60° C) by adjustment of a switch. In the SW1 Dip switch (tan switches), set switch 5 to ON to obtain 140°...
  • Page 37 Diagnos c Codes and Remedies WARNING Some of the checks below should be done by a licensed professional. Consumers should never a empt any ac on that they are not qualified to perform. Code Defini on Remedy Power interrup on during Bath Fill (Water will not flow when Turn o all hot water taps.
  • Page 38 LC2,…) O bu on on the temperature controller 5 mes. Repeated LC codes will eventually lockout “LC”) the water heater. Please call Rinnai technical department. Maintenance has been Indicates a licensed professional performed maintenance or corrected an issue. performed Clean inlet water supply filter.
  • Page 39: Required Maintenance

    Required Maintenance The appliance must be inspected annually by a licensed professional. Repairs and maintenance should be per formed by a licensed professional. The licensed professional must verify proper opera on a er servicing. WARNING To protect yourself from harm, before performing maintenance: Turn o the electrical power supply by unplugging the power cord or by turning o the electricity at the circuit breaker.
  • Page 40 WARNING Freeze Protec on Make sure that in case of freezing weather that the Tes ng the pressure relief valve should only be water heater and its water lines are adequately performed by a licensed professional. Scalding hot protected to prevent freezing. Damage due to water may be released under pressure.
  • Page 41: Flushing The Heat Exchanger

    flush the appliance will cause damage to the heat exchanger. Damage caused by lime build up is not covered by the unit’s warranty. Rinnai strongly recommends installa on of isola on valves to allow for flushing of the heat exchanger.
  • Page 42: Manual Draining Of The Water Heater

    Manual Draining of the Water Heater WARNING To avoid burns, wait un l the equipment cools down before draining the water. The water in the appliance will remain hot a er it is turned o . If the water heater is not going to be used during a period of possible freezing weather, it is recommended that the water inside the water heater be drained.
  • Page 43: State Regula Ons

    State Regula ons NOTICE BEFORE INSTALLATION This direct vent appliance must be installed by a licensed professional. If you are not properly trained, you must not install this unit. IMPORTANT: In the State of Massachuse s (248 CMR 4.00 & 5.00) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residen al purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termina on is less than seven (7) feet above finished grade in the area of the ven ng, including but not limited...
  • Page 44: Replacement Parts

    Replacement Parts The Technical Sheet which is located inside the front cover of the water heater contains a complete illustrated parts list. Tech Sheet Gas Control Assembly Electrode / Flame Rod Item No. Gas Control Assembly Electrode / Flame Rod Kit 116, 117 Fan Assembly / Motor Heat Exchanger...
  • Page 45: Consumer Warranty

    30 days of purchase at www.rinnairegistra on.com or by calling 1 866 RINNAI 1 (746 6241), except registra on is not required in California and Quebec.
  • Page 46 A mer added to a standard recircula ng pump is not considered as on demand. [2] Period of coverage is reduced to 5 years from date of purchase if the Rinnai water heater temperature se ng exceeds 160° F (71°C).
  • Page 47 For those without internet access, please call 1 866 RINNAI1 (746 6241). Receipt of Registra on by Rinnai will cons tute proof of purchase for this product. Registra on of product installed in new home construc on may be verified with a copy of the closing papers provided by the ini al home buyer.
  • Page 48: French Version

    Chau e eau d’intérieur sans réservoir à ven la on directe POUR LES APPLICATIONS INTÉRIEURES SEULEMENT Manuel d'installa on et RL75i .....REU VC2528FFUD US d'u lisa on REU VC2528FFUD(A) US RL94i .....REU VC2837FFUD US POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT RL75e ....REU VC2528WD US REU VC2528WD(A) US RL94e ....REU VC2837WD US ANS Z21.10.3...
  • Page 49 Nous allons cependant con nuer à vous contacter avec les informa ons per nentes pour le produit vous inscrit ou vous rendre compte avec nous. Si vous avez des ques ons ou se sentent que le manuel est incomplète, veuillez communiquer avec Rinnai au 1 800 621 9419.
  • Page 50: Les Pra Ques Et Les Comportements De Sécurité Pour Les Consommateurs Et Les Installateurs

    Les pra ques et les comportements de sécurité pour les consommateurs et les installateurs AVERTISSEMENT U lisez seulement votre main pour pousser ou Avant d'exploita on, une odeur tout autour de la tourner le bouton de contrôle des gaz. Ne jamais zone de l'appliance pour le gaz.
  • Page 51: Installa On D'instruc Ons

    Installa on d’instruc ons Qualifica ons d'installateur Instruc ons générales Un professionnel autorisé doit installer l'appareil, NE FAITES PAS inspecter et fuite de le tester avant de l'u liser. La Le RL75i et RL94i n'est pas prévu pour une garan e va être annulée en raison de la mauvaise installa on à...
  • Page 52: Préparez Vous À L'installa On

    Préparez vous à l'installa on L'appareil et sa vanne de gaz doivent être Pièces incluses débranchés de la conduite d'alimenta on en gaz Chau e eau sans Réservoir durant les essais du système en pression dépassant 1/2 psi (3.5 kPa ou 13,84 pouces de hauteur de Couleur froide codé...
  • Page 53: Déterminez L'endroit D'installa On

    à haute température. ho es de ven la on d'échappement. Un kit de traitement de l'eau est disponible depuis Rinnai. Ce kit Installez aussi loin que possible des bouches d'air fournit un contrôle de la préven on et à la corrosion calcaire inlet.
  • Page 54 Espacements pour terminaison de cheminée (ANS Z21.10.3, CSA 4.3) Vous devez installer une fin de vent à TERMINATION DÉTAIL D'ANGLE INSIDE Terminaison INTÉRIEUR CORNER DETAIL apporter dans l'air de combus on et d'expulser des gaz d'échappement. Clearance in Dédouanement en Ref.
  • Page 55 Dégagements addi onnels RL75e, RL94e Vérifier si les codes locaux remplacent ces habilita ons. Éviter les endroits de résilia on près d'un évent sécheur. Évitez les endroits de résilia on près d'échappement (50 mm) entre cuisson commercial. (0.91 m) à évent terminaux au so te ou eve ven lé...
  • Page 56 Dégagements d'unité Vers le haut to top to top Vers le haut Sur le côté to side Sur le côté to side to front Vers l'avant to front Vers l'avant to ground/bottom Vers le sol to ground/bottom Vers le sol Modèles d'intérieur: RL75i, RL94i Modèles extérieurs: RL75e, RL94e Jusqu'à...
  • Page 57 Longueur maximum de ven la on Protec on de gel 1. Déterminez le nombre de coudes à 90° dans le Assurez vous que dans le cas de congéla on météo système de ven la on (deux coudes à 45° que le chau e eau et ses lignes de l'eau sont protégés comptent pour un coude à...
  • Page 58: Liste De Vérifica On Pour Déterminez

    Bâ à murer Liste de vérifica on pour déterminer l'endroit d’installa on Le chau age de l'eau n'est pas corrosifs composés dans l'air. L'emplacement de chau age de l'eau est parenthèses conforme avec les dégagements. d'installa on de (Modèles d'intérieur) La ven la on prévue ne dépassera pas la longueur maximale pour le nombre de coudes u lisé.
  • Page 59: Installa On De La Mise À L'air Libre (Modèles D'intérieur)

    S'il devient nécessaire d'accéder à un système d'évacua on quatre pieds et tous les évents ver cale s'exécute fermée pour le service ou les répara ons, Rinnai n'est pas chaque six pieds ou conformément aux codes responsable des frais ou des di cultés à accéder au locaux.
  • Page 60 Installa on de conduit de cheminée (modèles d'intérieur) Résilia on horizontale sans u liser le collecteur de condensat * Un collecteur de condensat est requis sur les AVERTISSEMENT terminaisons horizontales si une éléva on ver cale dans le système de ven la on Si un collecteur de condensat n'est pas u lisé, le tuyau dépasse 5' (1,5 m).
  • Page 61: Condensat (Modèles D'intérieur)

    Condensat (modèles d'intérieur) L’INFORMATION La forma on de condensat peut arriver même sur les appareils à ven la on directe de haute performance. Un collecteur de condensat intégré. Pour éviter que le condensat n'endommage, suivez Dans les régions à climat froid il se produira plus ces instruc ons : de condensat dans le système de ven la on.
  • Page 62: Installa On De La Tuyauterie

    Vannes d'isolement sont inclus dans ce e chau e eau. drainage complet de la soupape et de la conduite. Rinnai recommande fortement l'installa on de vannes Ne pas placer toute autre soupape de type ou fermer d'isolement sur les lignes de l'eau chaude et froide.
  • Page 63 Installez Valve à Bille / Valve de dégagement de pression Les soupapes d'isolement offrent la possibilité d'isoler le chauffe eau de la structure plomberie et de permettre un accès rapide à vider l'échangeur de chaleur. Vérifiez auprès des codes locaux pour déterminer si une soupape de pression et de température est nécessaire.
  • Page 64 Tuyauterie recommandée pour installa on de base Rinnai Water Heater Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) Connexion de gaz en 3/4 po...
  • Page 65: Liste De Vérifica On Pour Tuyauterie

    U lisez toujours des connecteurs approuvés pour chau age de l'eau. Pression d'eau minimum est raccorder l'unité sur la conduite de gaz. Purgez de 50 psi. Rinnai recommande de 60 80 psi pour toujours la conduite de gaz de tous débris éventuels des performances op males.
  • Page 66 Tout composé u lisé sur la jonc on filetée du tuyau Table gaz naturel de gaz doit être d'un type qui résiste à l'ac on du gaz Tuyau métallique annexe 40 propane ou naturel. La pression Inlet : moins de 2 psi (55 pouces W.C.) La conduite d'alimenta on en gaz doit être étanche Chute de pression : 0,3 pouces W.C.
  • Page 67: Reliez L'électricité

    Reliez l'électricité Ajustez à l'haute al tude Définissez les valeurs indiquées dans le tableau ci AVERTISSEMENT dessous pour votre al tude commutateurs 2 et 3 N'u lisent pas une rallonge ou un adaptateur (SW1, commutateurs fauve). Le paramètre par brancher avec cet appareil. défaut pour l'appliance est 0 2000 (0 610 m) avec les commutateurs no 2 et 3 dans la posi on OFF.
  • Page 68: Installa On De Le Contrôleur De Température

    Installa on de le contrôleur de Montage du contrôleur température 1. Faire trois trous dans le mur, comme le montre. AVERTISSEMENT Outline of Remote Désac ver le pouvoir. Ne pas tenter de connecter les securing screw contrôleurs de température avec le pouvoir. Bien que le contrôleur est un disposi f de basse tension, il y a 1-21/32"...
  • Page 69: Liste De Vérifica On Finale

    Liste de vérifica on finale Le chau age de l'eau n'est pas corrosifs composés Veiller à ce qu'une soupape est installée avec une cote dans l'air. qui dépasse l'entrée de BTU du modèle de chau age de l'eau. Se référer à la plaque de cota on sur le côté L'approvisionnement en eau ne con ent pas de de la chau e eau pour l'entrée de BTU.
  • Page 70: Diagramme En Escalier

    Diagramme en escalier PHASE NEUTRE 2837 MODÈLE SEULEMENT POMPE RELAIS 3 FUSIBLE 10 A CONTACT DE DÉTECTION DE GEL ANTI-FOUDRE RELAIS 2 ANTI-FOUDRE RELAIS 1 ALLUMAGE TERRE ALIMENTATION D'ÉNERGIE DE COMMUTATION 170 V CC 12,6 V 40 V CC 5 V CC 0-5 V CC DÉTECTEUR ÉLECTRO-...
  • Page 71: Instruc Ons D'u Lisa On

    Faits importants sur votre chau e eau Je vous remercie pour l'achat d'un chau e eau sans réservoir Rinnai. Pour le bon fonc onnement et la sécurité, il est important de suivre les instruc ons et de respecter les mesures de sécurité.
  • Page 72: Direc Ves D'opéra Ons Du Consommateur Pour Le Fonc Onnement Sécuritaire De Votre Chau E Eau

    Direc ves d'opéra ons du consommateur pour le fonc onnement sécuritaire de votre chau e eau À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ AVERTISSEMENT Si vous ne suivez pas exactement ces instruc ons, il peut en résulter un départ d'incendie ou une explosion, causant dégâts matériels, blessures corporelles ou même mort.
  • Page 73: Comment Utiliser Le Contrôleur De Température

    Comment utiliser le contrôleur de température Dimensions (pouces): 3.5 W x 4.75 H x 0.75 D Le contrôleur de MC 91 2 est le contrôleur de température standard qui est fourni avec l'appareil de chau age de l'eau. Sur les modèles de l'intérieurs, elle est intégrée dans le panneau avant. Le contrôleur de MCC 91 2 est pour des applica ons commerciales et hydroniques nécessitant des températures plus élevées.
  • Page 74: Comment Définir La Temperature

    Comment définir la température Ce e chau e eau nécessite un débit minimum à exploiter. Ce taux se trouvent sur la page de spécifica on dans ce manuel. Dans certains cas lorsque vous n'obtenez pas l'eau chaude ou si l'eau alterne entre le chaud et le froid, c'est en raison du débit de l'eau étant ci dessous ou à...
  • Page 75 Plages de température avec un contrôleur de température Le chau e eau peut fournir l'eau à un seul réglage de la température à la fois. Les températures disponibles sont fournis ci dessous. Une température inférieure à 98° F (37 ° C) peut être obtenue dans l'eau du robinet en mélange à...
  • Page 76: Entre En Requis

    Entre en requis L'appareil doit être inspecté chaque année par un technicien qualifié. Répara ons et entre en doivent être e ectuées par un technicien qualifié. Le technicien de service doit vérifier le bon fonc onnement après entre AVERTISSEMENT Pour vous protéger contre les préjudices, avant d'e ectuer la maintenance : Coupez l'alimenta on électrique en débranchant le cordon d'alimenta on ou en désac vant l'électricité...
  • Page 77 Ne oyez le filtre à eau Protec on de gel Ne oyez le filtre à eau inlet en fermant les soupapes Assurez vous que dans le cas de congéla on météo d'isolement (fermeture) entrée froide et d'eau que le chau e eau et ses lignes de l'eau sont chaude.
  • Page 78: Flushing L'échangeur De Chaleur

    à l'échangeur de chaleur. Dommages causés par l'accumula on de chaux ne sont pas couvert par la garan e de l'unité. Rinnai recommande fortement l'installa on de vannes d'isolement pour perme re de chasse de l'échangeur de chaleur.
  • Page 79: Drainage Manuel Du Chau E Eau

    Drainage Manuel du chau e eau Pour éviter de burns, a endre jusqu'à ce que l'équipement se refroidit avant le AVERTISSEMENT drainage de l'eau. L'eau de l'appliance restera chaud après qu'il est éteint. Si le chau e eau ne va être u lisée pendant une période de temps au gel possible, il est recommandé que l'eau à l'intérieur du chau e eau être drainé.
  • Page 80: Garan E Du Consommateur

    ENREGISTREMENT REQUIS Rinnai o re la possibilité de prolonger votre garan e limitée Standard de Rinnai sur le travail uniquement sur les modèles de la série de Luxury RL75 et RL94 si vous enregistrer dans les 30 jours de l'achat de votre unité. Produits non homologués ser ont toujours couverts par le Rinnai produit standard garan e limitée, comme le prévoit le manuel d'instruc ons de fonc onne...
  • Page 81 Une minuterie ajoutée sur une pompe de recircula on standard n'est pas considérée comme donnant un système à la demande. Période de couverture est réduite à 5 ans à compter de la date d'achat, si le paramètre de température chau e eau Rinnai dépasse 160° F (71° C).
  • Page 82 Limita on sur les garan es Personne n'est autorisé à apporter toute autre garan e au nom de Rinnai pour ce produit. Sauf pour ce qui est expressément communiqué ici, il n'y a aucune autre garan e, explicite ou implicite, y compris sans y être limité les garan es de valeur marchande ou d'adéqua on à...
  • Page 83 VC Series Manual...
  • Page 84 • Up to 0.96 Energy Factor (EF) Applications • Internal or External Installation ® • ENERGY STAR qualified models • Pair up with the Rinnai Air Handler for efficient home heating Direct Vent Furnaces • High Efficiency • Vent Terminal A Included • Cool-to-the-touch Cabinet •...

Table of Contents