Rinnai V75i Installation And Operation Manual

Rinnai V75i Installation And Operation Manual

Direct vent tankless water heater
Hide thumbs Also See for V75i:
Table of Contents

Advertisement

Available languages

Available languages

FOR INDOOR APPLICATIONS ONLY 
V75i  . ......................  R EU‐VC2528FFU‐US 
V65i  . ......................  R EU‐VC2025FFU‐US 
FOR OUTDOOR APPLICATIONS ONLY 
V75e ......................  R EU‐VC2528W‐US 
V65e ......................  R EU‐VC2025W‐US 
READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER. 
This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper 
opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.   
A licensed professional must install the water heater according to the exact instruc ons on pages 4‐27. 
The consumer must read the en re manual to properly operate the water heater and to have regular maintenance 
performed. 
WARNING
—  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance. 
—  WHAT TO DO IF YOU SMELL GAS 
• Do not try to light any appliance. 
• Do not touch any electrical switch; do not use any phone in your building. 
• Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's instruc ons. 
• If you cannot reach your gas supplier, call the fire department. 
—  Installa on and service must be performed by a licensed professional. 
This en re manual must be le  for the consumer.  The consumer must read and  
refer to this manual for proper opera on and to maintain the water heater. 
ANS Z21.10.3  ● CSA 4.3 
If the informa on in these instruc ons is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death. 
Direct Vent Tankless Water Heater 
Installa on and Opera on Manual 

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai V75i

  • Page 1 Direct Vent Tankless Water Heater  Installa on and Opera on Manual  FOR INDOOR APPLICATIONS ONLY  V75i  .......  R EU‐VC2528FFU‐US  V65i  .......  R EU‐VC2025FFU‐US  FOR OUTDOOR APPLICATIONS ONLY  V75e ......  R EU‐VC2528W‐US  V65e ......  R EU‐VC2025W‐US  ANS Z21.10.3  ● CSA 4.3  READ ALL OF THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR OPERATING THIS WATER HEATER.  This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper  opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.    A licensed professional must install the water heater according to the exact instruc ons on pages 4‐27.  The consumer must read the en re manual to properly operate the water heater and to have regular maintenance  performed.  If the informa on in these instruc ons is not followed exactly, a fire or explosion ...
  • Page 2: Table Of Contents

    State Regula ons  ............ 40    Connect Electricity ........... 20  Replacement Parts .......... 41    Adjust for High Al tude ........ 20  Consumer Warranty .......... 42    Adjust for Vent Length (indoor models only) .. 20  French Version  ............ 44  NOTICE:  Rinnai some mes shares customer contact informa on with businesses that we believe provide  products or services that may be useful to you.  By providing this informa on, you agree that we can  share your contact informa on for this purpose.  If you prefer not to have your informa on shared with  these businesses, please contact customer service and ask not to have your informa on shared.  We  will however, con nue to contact you with informa on relevant to the product(s) you registered and/ or you account with us.  If you have any ques ons or feel that the manual is incomplete contact Rinnai at 1‐800‐621‐9419   Important Safety Informa on  Safety Defini ons  This is the safety alert symbol.  This symbol alerts you to poten al hazards that can kill or hurt you ...
  • Page 3: Safety Behaviors And Prac Ces For The Consumer And Installer

        Safety Behaviors and Prac ces for the Consumer and Installer    WARNING • • Before opera ng, smell all around the appliance  Use only your hand to push in or turn the gas  control knob.  Never use tools.  If the knob will not  area for gas.  Be sure to smell next to the floor  push in or turn by hand, do not try to repair it; call a  because some gas is heavier than air and will se le  on the floor.  licensed professional.  Force or a empted repair  may result in a fire or explosion.  • Keep the area around the appliance clear and free  • from combus ble materials, gasoline, and other  Do not use this appliance if any part has been under  water.  Immediately call a licensed professional to  flammable vapors and liquids.  inspect the appliance and to replace any part of the  • Combus ble construc on refers to adjacent walls  control system and any gas control which has been  and ceiling and should not be confused with  under water.  combus ble or flammable products and materials.   • Do not use subs tute materials.  Use only parts  Combus ble and/or flammable products and ...
  • Page 4: Installa On Instruc Ons

      Installa on Instruc ons  Installer Qualifica ons  General Instruc ons  A licensed professional must install the appliance,  DO NOT  inspect it, and leak test it before use.  The warranty  • Do not install the V75i or the V65i outdoors.  will be voided due to improper installa on.  • Do not install the V75e or the V65e indoors.  The installer should have skills such as:  • Do not install the appliance in an area where water  • gas sizing  leakage of the unit or connec ons will result in  • connec ng gas lines, water lines, valves,  damage to the area adjacent to the appliance or to  electricity,   lower floors of the structure.  When such loca ons  • knowledge of applicable na onal, state, and  cannot be avoided, it is recommended that a  local codes.  suitable drain pan, adequately drained, be installed  • installing ven ng through a wall or roof ...
  • Page 5: Prepare For Installa On

      Prepare for installa on  • The appliance must be isolated from the gas supply  Parts included  piping system by closing its individual manual  shutoff valve during any pressure tes ng of the gas  • Tankless water heater  supply piping system at test pressures equal to or  • less than 1/2 psi (3.5 kPa) (13.84 in W.C.).  MC‐91‐2 temperature controller (integrated into  indoor models; provided with outdoor models)  • You must follow the installa on instruc ons and  those in Care and Maintenance for adequate  combus on air intake and exhaust.  Tools needed  INFORMATION  • • Pipe wrenches (2)  Gloves  • If a water heater is installed in a closed water  • • Adjustable pliers  Safety glasses  supply system, such as one having a backflow  • • preventer in the cold water supply line, means ...
  • Page 6: Determine Installa On Loca On

    * Source: Part 143 Na onal Secondary Drinking Water  Regula ons    Outdoor/External Water Heaters and Vent  Termina ons of Indoor/Internal Water Heaters  If you install this water heater in an area that is  • Install the water heater as far away as possible  known to have hard water or that causes scale build‐ from exhaust vent hoods.  up the water must be treated and/or the heat  • Install as far away as possible from air inlet  exchanger flushed regularly.  vents.  Corrosive fumes may be released through  When scale build‐up in the heat exchanger begins to  these vents when air is not being brought in  affect the performance of the water heater, a  through them.  diagnos c code “LC#” will display.  Flush the heat  • Chemicals that are corrosive in nature should not  exchanger to prevent damage to it.  Scale build up is  be stored or used near the water heater or vent  caused by hard water set at a high temperature.    termina on.  Rinnai provides a “Scale Control System” that offers  Damage and repair due to corrosive compounds in  superior lime scale preven on and corrosion control  the air is not covered by warranty.  by feeding a blend of control compounds into the  water supply.  6  Value Series Manual ...
  • Page 7   Vent Termina on Clearances  For indoor models, you must install a vent termina on to bring in combus on air and expel exhaust.  TERMINATION INSIDE CORNER DETAIL Clearance in Ref. A also applies to anticipated snow line SNOW FIXED CLOSED OPERABLE FIXED AIR SUPPLY INLET  CLOSED OPERABLE VENT TERMINAL  AREA WHERE TERMINAL  IS NOT PERMITTTED  Ref  Descrip on  Canadian Installa ons  US Installa ons  A  Clearance above grade, veranda, porch, deck, or balcony  12 inches (30 cm) ...
  • Page 8   Addi onal clearances ‐ V75i, V65i  60" (1.52 m)  Check on whether local codes supersede these clearances.  between   • terminals at  Avoid termina on loca ons near a dryer vent.  different levels  • Avoid termina on loca ons near commercial  cooking exhaust.  • You must install a vent termina on at least 12  inches from the ground  Important considera ons for loca ng vent  termina on under a soffit (ven lated or unven lated  or eave vent; or to a deck or porch)  • Do not install vent termina on under a soffit vent  such that exhaust can enter the soffit vent  (1.52 m) ver cally  60" between terminals  • Install vent termina on such that exhaust and ...
  • Page 9   Addi onal clearances   V75e, V65e  Local codes supersede these clearances.  • Avoid termina on loca ons near a dryer vent.  • Avoid termina on loca ons near commercial  cooking exhaust.  (50 mm) between  terminals at same  level  (0.91 m) to ven lated or unven lated  36" soffit or eve vent; or to a deck or porch  12" 2" (0.30 m) to an  inside corner  (1.52 m) ver cally  60" between terminals    Value Series Manual  9 ...
  • Page 10   Unit clearances  to top to top to side to side to front to front to ground/bottom to ground/bottom Indoor models:  V75i, V65i  Outdoor models:  V75e, V65e    to Non‐   to Non‐ to Combus bles  to Combus bles  Combus bles  Combus bles    inches (mm)     inches (mm)   inches (mm)      inches (mm)      Top of Heater  6 * (152) ...
  • Page 11   Maximum vent length   Freeze Protec on  (indoor models only)  Make sure that in case of freezing weather that the  water heater and its water lines are protected to  1.  Determine the number of 90 degree elbows in  prevent freezing.  Damage due to freezing is not  the vent system.  (Two 45 degree elbows count as  covered by the warranty.  one 90 degree elbow.)  Loss of freeze protec on may result in water damage  2.  Refer to the table to find the maximum vent  from a burst heat exchanger or water lines.    length based on the number of elbows.  With electrical power supplied, the water heater will  not freeze when the outside air temperature is as cold  Number of  Maximum vent length  as –22°F (‐30°C) for indoor models or is as cold as –4°F  90° Elbows  (‐20°C) for outdoor models, when protected from  0  41   (12.5 m) 1  direct wind exposure.  Because of the “wind‐chill”  effect, any wind or circula on of the air on the unit  1  35   (10.7 m) 2  will reduce its ability to freeze protect.  2  29   (8.8 m) 3  The unit may be drained manually.  However, it is  3 ...
  • Page 12: Checklist To Determine Installa On Loca On

      Mount to Wall  Checklist  to Determine Installa on  Loca on  □  The water heater is not exposed to corrosive  compounds in the air.  □  The water heater loca on complies with the  wall installa on  clearances.  brackets  □  For indoor models, the planned ven ng will not  exceed the maximum length for the number of  elbows used.    □  The planned ven ng termina on/air intake  loca on meets the clearances.  □  The water supply does not contain chemicals or  1.  Iden fy the installa on loca on and confirm that  exceed total hardness that will damage the heat  the installa on will meet all required clearances.  exchanger.  □ 2.  Securely a ach the water heater to the wall   ...
  • Page 13: Installa On Of Ven Ng (Indoor Models Only)

      Installa on of ven ng (indoor models only)  Install the correct ven ng for your model according to the ven ng manufacturer’s instruc ons and the  guidelines below.  Refer to the manufacturer’s technical literature for specific part numbers and instruc ons.    Listed and Tested Vent Products  Manufacturer  Telephone  Fax  Contact  for V75i and V65i  Ubbink  Rolux Vent System   800‐621‐9419  678‐829‐1666  www.rinnai.us  custsvc@heat‐fab.com,  Heat‐Fab  Saf‐T Vent SC system  800‐772‐0739  413‐863‐4803  www.hea ab.com  info@mtlfab.com,  Metal‐Fab  Corr/Guard Vent/Air Intake System  800‐835‐2830  316‐943‐2717  www.metal‐fabinc.com    Ven ng Guidelines       ...
  • Page 14   Flue Installa on (indoor models only)   Install the ven ng termina on according to the diagrams and instruc ons below.  Horizontal Termina on without using the Condensate Collector  WARNING * The condensate collector must be used in  horizontal termina ons if a ver cal rise in  If the condensate collector is not used, the drain pipe  the vent system exceeds 5 .  must be capped to prevent exhaust gases and  condensate from entering the building.  The cap is  supplied on the appliance.  Maximum Height *  Regions of cold climate will create more  5 feet (1.52 m)  condensate in the vent system.  The  condensate collector should be used in  cold climates.  If more than one elbow is used in the  ver cal sec on the condensate collector  must be used.  Horizontal Termina on using the  Ver cal Termina on   Condensate Collector  (condensate collector must be used in all installa ons)  Condensate ...
  • Page 15: Condensate (Indoor Models Only)

      Condensate  (indoor models only)  INFORMATION  Condensate forma on can occur in high efficiency  direct vent appliances.  Without proper drainage  • A condensate trap is available, P/N 222053.    condensate will damage the heat exchanger.    • Regions of cold climate will create more  To prevent condensate damage follow these  condensate in the vent system.  The condensate  instruc ons.  collector should be used in cold climates.  DO NOT  • The condensate drain pipe should be as short as  • possible and have a downward pitch.  Do not allow condensate to enter the water  heater.  • Do not connect the condensate drain pipe directly  to the rain sewer.  • Do not connect the condensate drain line with an  air condi oning evaporator coil drain.  MUST DO  • Use only vent that is approved and iden fied as  acceptable for your par cular model.  • For ver cal termina ons, install a condensate drain  and trap as close as possible to the appliance. ...
  • Page 16: Installa On Of Plumbing

    The American Na onal Standard (ANSI Z21.10.3) servicing.  does not require a combina on temperature and  DO NOT  pressure relief valve for this appliance.  However,  • Do not plug the relief valve and do not install any  local codes may require a combina on  reducing fi ngs or other restric ons in the relief  temperature and pressure relief valve.  line.  The relief line should allow for complete  Isola on Valves    drainage of the valve and the line. Rinnai strongly recommends the installa on of  • Do not place any other type valve or shut off  isola on valves on the cold and hot water lines  device between the relief valve and the water  because they provide the ability to isolate the water    heater. heater from the structure’s plumbing and allow quick  MUST DO  access to flush the heat exchanger.  Flushing the heat  exchanger regularly is required as part of the proper  • The relief valve must comply with the standard for ...
  • Page 17   Piping Diagram for Basic Installa on    Rinnai Water Heater   Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) 3/4" Hot Water Supply Line For Building Fixtures This is not an engineered drawing.
  • Page 18: Checklist For Plumbing

    Before placing the appliance in opera on all joints  □  Clean the inlet water filter by closing the cold and  including the heater must be checked for gas  hot water inlet isola on (shut‐off) valves.  Put a  ghtness by means of leak detector solu on, soap  bucket under the filter at the bo om of the water  and water, or an equivalent nonflammable  solu on, as applicable.  (Since some leak test  heater to catch any water that is contained inside  solu ons, including soap and water, may cause  the unit.  Unscrew the water filter.  Rinse the  filter to remove any debris.  Install the filter and  corrosion or stress cracking, the piping shall be  open the isola on valves.  rinsed with water a er tes ng, unless it has been  determined that the leak test solu on is non‐ □  Check for proper water pressure to the water  corrosive.)  heater.  Minimum water pressure is 50 psi.  Rinnai  • Use approved connectors to connect the unit to  recommends 60‐80 psi for maximum  the gas line.  Purge the gas line of any debris  performance.  before connec on to the water heater.  18  Value Series Manual ...
  • Page 19 608  1150  2350  of gas or the required BTU/hour.  20  200  418  787  1620  Example:    30  160  336  632  1300  The hea ng value of natural gas for your loca on is  1000 BTU/FT .  The gas input of the V75i is 180,000  40  137  287  541  1110  BTU/HR.  Addi onal appliances at the loca on require  50  122  255  480  985  65,000 BTU/hr.  Therefore the cubic feet per hour =  (180,000 + 65,000) / 1000 = 245 FT /HR.  If the pipe  60  110  231 ...
  • Page 20: Connect Electricity

      Connect Electricity  Adjust for High Al tude   WARNING For the V75i/e, on the SW1 DIP switch (tan switches),  set switches 2 and 3 to the values shown in table  Do not use an extension cord or an adapter plug with  below for your al tude.  The default se ng for the  this appliance.  appliance is 0‐2000   (0‐610 m) with switches No. 2  The water heater must be electrically grounded in  and No. 3 in the OFF posi on.  When the DIP switch is  accordance with local codes and ordinances or, in the  adjusted, it is not necessary to adjust the gas pressure  absence of local codes, in accordance with the  se ng for high al tude.  Na onal Electrical Code, ANSI/NFPA No. 70.  SW1  SW1  Al tude  Switch No.  Switch No.  Indoor water heaters are equipped with a three‐ 2  3  prong (grounding) plug for your protec on against  shock hazard and should be plugged directly into a  0‐2000   (0‐610 m)  OFF ...
  • Page 21: Installa On Of Temperature Controller

    Installa on of Temperature Controller  Configura ons  WARNING A maximum of 4 temperature controllers can be  Turn the power off.  Do not a empt to connect the  installed for a water heater or bank of water heaters.   temperature controllers with the power on.  Although  This includes the controller built into an indoor water  the controller is a low voltage device, there is 120 volt  heater.  Controllers can only be wired in parallel.   poten al next to the temperature controller  Controllers cannot be wired in series.  connec ons inside the unit.    Do not connect the temperature controller to the  Maximum 4 Controllers Rinnai 120VAC terminals provided for the op onal solenoid  Water drain valves.    Heater Indoor models have their controller built into the  front panel.  Addi onal controllers can be installed.  Wire controllers in parallel  Controller Loca on  • The 4 temperature controllers can consist of mul ple  The controller should be out of reach of small  MC‐91‐2 or MCC‐91‐2 but only one BC‐100V and only   children.  one MC‐100V.   ...
  • Page 22   Moun ng the controller  1.  Make three holes in the wall as shown.  Outline of Remote securing screw 1-21/32" wiring hole 3-5/16" securing screw 2.  Run the cable between the controller and the  water heater or the controller and another  controller.  3.  Remove the face plate from the temperature  controller using a screwdriver.  4.  Connect the cable to the temperature controller.  5.  Mount the controller to the wall using the holes  drilled in step 1.  6.  Disconnect the power from the water heater.  7.  Remove the plas c cover from the PCB and  electrical connec ons.  8.  Thread the cable through the access hole at the  base of the unit and connect the wires to the  controller terminals on the right hand side bo om  of the PCB. ...
  • Page 23: Final Checklist

    Confirm that the electricity is supplied from a 120  □  Clearances from the vent termina on / air intake  VAC, 60 Hz power source, is in a properly  are met.  grounded circuit, and  turned on.  □  For indoor models, ensure you have used the  □  Verify the temperature controller is func oning  correct ven ng products for the model installed  properly.  and that you have completely followed the  □  For the V75i/e, verify that switches No. 2 and No.  ven ng manufacturer’s installa on instruc ons  3 in the SW1 DIP switch (tan switches) is set  and these installa on instruc ons.  correctly for your al tude.    □  For indoor models, verify that the vent system  □  Verify the system is func oning correctly by  does not exceed the maximum length for the  connec ng your manometer to the gas pressure  number of elbows used.  test port on the water heater.  Operate all gas  □  For indoor models verify that switch No. 1 in the ...
  • Page 24: Technical Data

      Technical Data  Specifica ons    V75i  V65i  V75e  V65e  Minimum Gas Consump on Btu/h   10,300  Maximum Gas Consump on Btu/h   180,000  150,000  180,000  150,000   0.26 ‐ 7.5 GPM  0.26 ‐ 6.6 GPM  0.26 ‐ 7.5 GPM  0.26 ‐ 6.6 GPM  Hot water capacity (Min ‐ Max) *  (1.0 ‐ 28.5 L/min)  (1.0 ‐ 25.0 L/min)  (1.0 ‐ 28.5 L/min)  (1.0 ‐ 25.0 L/min)  Temperature Se ng (no controller)   120° F (49° C)  or 140° F (60° C)   Maximum Temp Se ng (residen al)   Selectable at 120° F (49° C) or at 140° F (60° C)   Minimum Temperature Se ng   98° F (37° C)  Weight   45.6 lb (20.7 kg)   43.6 lb (19.8 kg)  ...
  • Page 25: Dimensions

      Dimensions   Inches (millimeters)  V75i, V65i  9.27 (235.5)  14.04 (356.6)  0.4~1.8(10~45) Variable  5.05 (128.1)  B  C  E  F  G  D  DIMENSION  Inches (mm)  DIMENSION  Inches (mm)  A (GAS)  1.31 (33.2)  D  4.33 (110)  A (COLD)  1.93 (49)  E  2.89 (73.3)  A (HOT)  1.35 (34.4)  F  1.85 (47)  B  4.21 (106.9)  G  3.44 (87.3)  A  C  1.17 (29.8)     ...
  • Page 26   Pressure Drop Curve   V65i/e  V75i/e  60.00 55.00 50.00 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 Water Flow (gpm)  Water Flow Curve                                      10.0 V75i/e ...
  • Page 27: Ladder Diagram

        Ladder Diagram                                      Value Series Manual  27 ...
  • Page 28: Opera On Instruc Ons

    FOR INDOOR APPLICATIONS ONLY  V75i ...... REU‐VC2528FFU‐US  V65i ...... REU‐VC2025FFU‐US  FOR OUTDOOR APPLICATIONS ONLY  V75e ..... REU‐VC2528W‐US  V65e ..... REU‐VC2025W‐US  Important Facts about your Water Heater  Thank you for purchasing a Rinnai Tankless Water Heater.  For proper opera on and safety, it is  important to follow the instruc ons and adhere to the safety precau ons.    Read all of the instruc ons and the warranty thoroughly before opera ng this water heater.  Keep this  manual in a safe place.  NOTICE:  Rinnai some mes shares customer contact informa on with businesses that we believe provide  products or services that may be useful to you.  By providing this informa on, you agree that we can  share your contact informa on for this purpose.  If you prefer not to have your informa on shared with  these businesses, please contact customer service and ask not to have your informa on shared.  We  will however, con nue to contact you with informa on relevant to the product(s) you registered and/or  you account with us.  If the informa on in these instruc ons is not followed exactly, a fire or  WARNING explosion may result causing property damage, personal injury or death.  —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  other appliance.  —  WHAT TO DO IF YOU SMELL GAS ...
  • Page 29: Consumer Opera On Guidelines For The Safe Opera On Of Your Water Heater

      Consumer Opera on Guidelines for the Safe Opera on of your Water Heater     FOR YOUR SAFETY READ BEFORE OPERATING       WARNING    If you do not follow these instruc ons exactly, a fire or explosion  may result causing property damage, personal injury or loss of life.  A.  This appliance does not have a pilot.  It is  neighbor’s phone.  Follow the gas supplier’s  equipped with an igni on device which  instruc ons.  automa cally lights the burner.  Do not try to light  • If you cannot reach your gas supplier, call the fire  the burner by hand.  department.  B.  BEFORE OPERATING smell all around the appliance  C.  Use only your hand to push in or turn the gas  area for gas.  Be sure to smell next to the floor  control knob.  Never use tools.  If the knob will not  because some gas is heavier than air and will  push in or turn by hand, do not try to repair it, call  se le on the floor.  a qualified licensed professional.  Force or    WHAT TO DO IF YOU SMELL GAS  a empted repair may result in a fire or explosion.  •...
  • Page 30: How To Use The Temperature Controller

    MC-91-2US Button turned off.  Opera ng the water heater in this way to  alternately produce hot water may cause water to  condense on the outside of internal parts and  accumulate in the water heater cabinet.  WARNING • • Before opera ng, smell all around the appliance  If you install this water heater in an area that is  area for gas.  Be sure to smell next to the floor  known to have hard water or that causes scale build because some gas is heavier than air and will se le  ‐up the water must be treated and/or the heat  on the floor.  exchanger flushed regularly.  Rinnai provides a  “Scale Control System” that offers superior lime  • Keep the area around the appliance clear and free  scale preven on and corrosion control by feeding a  from combus ble materials, gasoline, and other  blend of control compounds into the water supply.   flammable vapors and liquids.  Damage and repair due to corrosive compounds in  • Always check the water temperature before  the air is not covered by warranty.  entering a shower or bath.  • Keep the air intake loca on free of chemicals such  • Do not use this appliance if any part has been under ...
  • Page 31: How To Set The Temperature

      How to Set the Temperature   This water heater requires a minimum flow rate to operate.  This rate can be found on the specifica on page in  this manual.  In some cases when you are not ge ng hot water or if the water alternates between hot and cold,  it is due to the water flow being below or close to the minimum flow rate.  Increasing the flow rate should  resolve these problems in these cases.  If you are experiencing issues with higher temperature se ngs, then reduce the temperature se ng.  Selec ng a  temperature closer to that which is actually used at the faucet will increase the amount of hot water being  delivered to the faucet, due to less cold water mixing at the fixture.  Hot water can be dangerous, especially for infants or children, the elderly,            DANGER  or infirm.  There is hot water scald poten al if the thermostat is set too high.  Water temperatures over 125° F (52° C) can cause severe burns or scalding  resul ng in death.  Hot water can cause first degree burns with exposure for as li le as:    3 seconds at 140° F (60° C)    20 seconds at 130° F (54° C)    8 minutes at 120° F (49° C)  Test the temperature of the water before placing a child in the bath or  shower.  Do not leave a child or an infirm person in the bath unsupervised.  1.  If the water heater is off, press  While any hot water is being provided,  NOTICE  the Power bu on to turn on.  the temperature se ng can only be  adjusted between 98° F and 110° F. ...
  • Page 32   Temperatures Available with a Controller   The water heater can deliver water at only one temperature se ng at a  me.  The available temperatures are  provided below.  A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.  To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off” bu on  for 5 seconds while the water heater is OFF.  Temperature Se ngs Available (Fahrenheit °F)  V75i/e, V65i/e  98   100   102   104   106   108   110   115   120   *   *   *   *   **   **   Celsius  °C  37  38  39  40  41  42  43  46  49  52  54 ...
  • Page 33: Diagnos C Codes

      Diagnos c Codes  This water heater is designed to display diagnos c codes. If there is a poten al opera on concern refer to the  code and remedy on the next page.  To Display Diagnos c Informa on   To display the most recent diagnos c codes press and hold the “On/Off” bu on for 2 seconds on the MC‐91‐2  controller.  While holding the “On/Off” bu on press the up bu on.  The last 9 diagnos c codes will flash one  a er the other.  To exit this mode press the “On/Off” and up bu on as before.  To enter or exit the maintenance monitor informa on mode press and hold the down bu on for 2 seconds and  without releasing it press the ON/OFF bu on.    To obtain the water flow rate press the up or down bu ons un l “01” displays.  The water flow rate will then  appear.  For example “58” means 5.8 gal/min.    To obtain the outgoing water temperature press the up or down bu ons un l “02” displays.  The temperature  will appear in degrees Fahrenheit.  No.  Data  Unit  01  Water flow rate  0.1 gal/min ...
  • Page 34   Diagnos c Codes and Remedies   Some of the checks below should be done by a licensed professional.  Consumers  WARNING should never a empt any ac on that they are not qualified to perform.  Code  Defini on    Remedy  03  Power interrup on during Bath  Fill (Water will not flow when    Turn off all hot water taps. Press ON/OFF twice.  power returns).  10   Air Supply or Exhaust Blockage   Check that nothing is blocking the flue inlet or exhaust.    Check all vent components for proper connec ons.  Ensure approved ven ng materials are being used.  licensed  Ensure vent length is within limits.  professional  Verify dip switches are set properly.  only  Check fan for blockage.  11   No Igni on   Check that the gas is turned on at the water heater, gas meter, or cylinder.  (heater not turning on)   ...
  • Page 35 Scale Build‐up in Heat  LC #  manual.  Hard water must be treated to prevent scale build up or damage to the heat  Exchanger (when checking  (LC0,  exchanger.  maintenance code history,    LC1,  To operate the water heater temporarily un l the heat exchanger can be flushed, push the On/ “00” is subs tuted for  LC2,…)  Off bu on on the temperature controller 5  mes.  Repeated LC codes will eventually lockout  “LC”)   the water heater.  Please call Rinnai technical department.  Maintenance has been  FF    Indicates a licensed professional performed maintenance or corrected an issue.  performed  Clean inlet water supply filter.    On new installa ons ensure hot and cold water lines are not reversed.  Verify you have at least the minimum flow rate required to fire unit.  Check for cold to hot cross over. Isolate circula ng system if present.  Turn off cold water to the  No  Nothing happens when  unit, open pressure relief valve; if water con nues to flow, there is bleed over in your plumbing.  code   water flow is ac vated.  ...
  • Page 36: Required Maintenance

      Required Maintenance  The appliance must be inspected annually by a licensed professional.  Repairs and maintenance should be per‐ formed by a licensed professional.  The licensed professional must verify proper opera on a er servicing.  WARNING To protect yourself from harm, before performing maintenance:  • Turn off the electrical power supply by unplugging the power cord or by turning off the electricity at the  circuit breaker.  (The temperature controller does not control the electrical power.)  • Turn off the gas at the manual gas valve, usually located immediately below the water heater.  • Turn off the incoming water supply.  This can be done at the isola on valve immediately below the water  heater or by turning off the water supply to the building.  Keep the appliance area clear and free from combus ble materials, gasoline, and other  WARNING flammable vapors and liquids.  The following maintenance items are required for the proper opera on of your water heater.  The appliance must be inspected annually by a  Motors  licensed professional.  Repairs and maintenance  Motors are permanently lubricated and do not need  should be performed by a licensed professional.  The  periodic lubrica on.  However you must keep fan and  licensed professional must verify proper opera on  motor free of dust and dirt by cleaning annually.  a er servicing.  Temperature Controller  Cleaning  Use a so  damp cloth to clean the temperature  It is impera ve that control compartments, burners,  controller.  Do not use solvents. ...
  • Page 37   Freeze Protec on  WARNING Make sure that in case of freezing weather that the  Tes ng the pressure relief valve should only be  water heater and its water lines are adequately  performed by a licensed professional.  Scalding hot  protected to prevent freezing.  Damage due to  water may be released under pressure.  freezing is not covered by the warranty.  Refer to the    sec on on Freeze Protec on. Pressure Relief Valve:  Winterizing  Operate the valve manually once a year.  In doing so,  These recommenda ons are intended to suggest  it will be necessary to take precau ons with regard to  prac ces which are effec ve for winterizing the water  the discharge of poten ally scalding hot water under  heater.  They should be used as a guide only.  No  pressure.  Ensure discharge has a place to flow.   liability is assumed for any issues resul ng from the  Contact with your body or other property may cause  use of this informa on.  damage or harm.  GAS  Visual Inspec on of Flame  Shut off the gas to the water heater.  It is generally  Verify proper opera on a er servicing.   ...
  • Page 38: Flushing The Heat Exchanger

      Flushing the heat exchanger  An LC0~LC9 or “00” diagnos c code indicates the unit is beginning to lime up and must be flushed.  Failure to  flush the appliance will cause damage to the heat exchanger.  Damage caused by lime build‐up is not covered by  the unit’s warranty.  Rinnai strongly recommends installa on of isola on valves to allow for flushing of the heat  exchanger.  1.  Disconnect electrical power to the water heater.  2.  Close the shutoff valves on both the hot water and  Pressure Regulator 3/4" Ball Valve cold water lines (V3 and V4).  Circulating Pump 3/4" Union 3.  Connect pump outlet hose (H1) to the cold water  line at service valve (V2).  Check Valve Boiler Drain Valve 4.  Connect drain hose (H3) to service valve (V1).  Pressure Relief Valve Solenoid Valve 5.  Pour 4 gallons (15.1 liters) of undiluted virgin, food ...
  • Page 39: Manual Draining Of The Water Heater

      Manual Draining of the Water Heater  To avoid burns, wait un l the equipment cools down before draining the water.  The  WARNING water in the appliance will remain hot a er it is turned off.  If the water heater is not going to be used during a period of possible freezing weather, it is recommended that  the water inside the water heater be drained.    To manually drain the water:  1.  Shut off cold water supply and gas supply.  Water  2.  Turn off the temperature controller.  Hot water  filter  3.  Disconnect the power to the water heater.  outlet  4.  Place a container to catch the water. Remove the drain caps on  both isola on valves and open both valves above the caps (blue  and red valve handles).  ‐OR‐  Open the pressure relief valve.  5.  Remove water filter to drain the cold water.  To resume normal opera on:  1.  Confirm that the gas supply is turned off, and that all taps are  closed.  2.  Screw in the water filter in the cold water inlet.  3.  Replace the drain caps and close both isola on valves. ‐OR‐  Close  the pressure relief valve.  Cold water  4.  Open the cold water supply.  inlet ...
  • Page 40: State Regula Ons

      State Regula ons  NOTICE BEFORE INSTALLATION    This direct‐vent appliance must be installed by a licensed professional. If you are not properly trained, you  must not install this unit.  IMPORTANT:  In the State of Massachuse s (248 CMR 4.00 & 5.00)  For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or  structure used in whole or in part for residen al purposes, including those owned or operated by the  Commonwealth and where the side wall exhaust vent termina on is less than seven (7) feet above  finished grade in the area of the ven ng, including but not limited to decks and porches, the following  requirements shall be sa sfied:   1.  INSTALLATION OF CARBON MONOXIDE DETECTORS. At the  me of installa on of the side wall  horizontal vented gas fueled equipment, the installing plumber or gasfi er shall observe that a hard  wired carbon monoxide detector with an alarm and ba ery back‐up is installed on the floor level  where the gas equipment is to be installed. In addi on, the installing plumber or gasfi er shall  observe that a ba ery operated or hard wired carbon monoxide detector with an alarm is installed on  each addi onal level of the dwelling, building or structure served by the side wall horizontal vented  gas fueled equipment. It shall be the responsibility of the property owner to secure the services of  qualified licensed professionals for the installa on of hard wired carbon monoxide detectors  a.  In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl  space or an a c, the hard wired carbon monoxide detector with alarm and ba ery back‐up may  be installed on the next adjacent floor level. ...
  • Page 41: Replacement Parts

      Replacement Parts  The Technical Sheet which is located inside the front  cover of the water heater contains a complete  illustrated parts list.    Tech Sheet   Gas Control Assembly  Electrode / Flame Rod  Item No.   Gas Control Assembly  100  Electrode / Flame Rod Kit  116, 117  Fan Assembly / Motor  125  Heat Exchanger  143  Water Flow Servo & Sensor  401  Bypass‐Servo Assembly  403  Fan Assembly / Motor  Heat Exchanger  Water Filter Assy  412  PC Board  700  Ignitor  706  Thermal Fuse Harness  725  Bypass‐Servo Assembly  Water Flow Servo &  Water Filter Assy  PC Board  Sensor  Ignitor  Thermal Fuse Harness    Value Series Manual ...
  • Page 42: Consumer Warranty

                          What is covered?  This Warranty covers any defects in materials or workmanship when the product is installed and operated according  to Rinnai wri en installa on instruc ons, subject to the terms within this Limited Warranty document.  This Warranty  applies only to products that are installed correctly.  Improper installa on may void this Warranty.  Rinnai strongly  suggests that you use a licensed professional who has a ended a product knowledge class before installing this water  heater.  This Warranty extends to the original purchaser and subsequent owners, but only while the product remains  at the site of the original installa on.  This Warranty only extends through the first installa on of the product and  terminates if the product is moved or reinstalled at a new loca on.  How long does coverage last?  Period of Coverage (from date of purchase)  If installed with a tankless  If used for both residen al  Item   Residen al Applica ons   isola on valve kit for residen al  water hea ng and space ...
  • Page 43 Any implied warran es of merchantability and fitness arising under state law are limited in dura on to the period of  coverage provided by this limited Warranty, unless the period provided by state law is less.  Some states do not allow  limita ons on how long an implied Warranty lasts, so the above limita on may not apply to you.  This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  NOTICE:  Rinnai some mes shares customer contact informa on with businesses that we believe provide products or  services that may be useful to you.  By providing this informa on, you agree that we can share your contact  informa on for this purpose.  If you prefer not to have your informa on shared with these businesses,  please contact customer service and ask not to have your informa on shared.  We will however, con nue to  contact you with informa on relevant to the product(s) you registered and/or you account with us.    Value Series Manual  43 ...
  • Page 44   Chauffe‐eau d’intérieur sans réservoir  à ven la on directe  Manuel d'installa on et d'u lisa on  POUR LES APPLICATIONS INTÉRIEURES SEULEMENT  V75i.......  R EU‐VC2528FFU‐US  V65i.......  R EU‐VC2025FFU‐US  POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT  V75e  ......  R EU‐VC2528W‐US  V65e  ......  R EU‐VC2025W‐US  ANS Z21.10.3  ● CSA 4.3  LIRE TOUTES LES INSTRUCTIONS SOIGNEUSEMENT AVANT D’INSTALLER OU D’EXPLOITATION DE CETTE  CHAUFFE‐EAU.  Ce manuel fournit des informa ons sur l'installa on, l'exploita on et l'entre en du chauffe‐eau.  Pour la sécurité et le bon  fonc onnement, il est important de suivre les instruc ons et de respecter les mesures de sécurité.  Un professionnel autorisé doit installer le chauffe‐eau conformément aux instruc ons exactes de sur pages 47‐65. ...
  • Page 45 Flushing l'échangeur de chaleur  .... 73  Installa on de la tuyauterie  ...... 58    Drainage Manuel du chauffe‐eau  .... 74  Liste de vérifica on  pour tuyauterie .... 60  Installa on de la fourniture de gaz  .... 60  Garan e du consommateur ........ 75  Reliez l'électricité  ........... 62  AVIS: Rinnai partage parfois des informa ons de contact client avec des entreprises que nous croyons offrent  des produits ou des services qui peuvent vous être u les.  En fournissant ces renseignements, vous accept‐ ez que nous pouvons partager vos coordonnées à ce e fin.  Si vous préférez ne pas avoir vos informa ons  partagées avec ces entreprises, veuillez contacter le service clientèle et demandez ne pas d'avoir votre in‐ forma on partagée.  Nous allons cependant con nuer à vous contacter avec les informa ons per nentes  pour le produit vous inscrit ou vous rendre compte avec nous.  Si vous avez des ques ons ou se sentent que le manuel est incomplète, veuillez communiquer avec Rinnai au        1‐800‐621‐9419.  L'informa on de sûreté importante ...
  • Page 46: Les Pra Ques Et Les Comportements De Sécurité Pour Les Consommateurs Et Les Installateurs

      Les pra ques et les comportements de sécurité pour les consommateurs et  les installateurs          AVERTISSEMENT  • • U lisez seulement votre main pour pousser ou  Avant d'exploita on, une odeur tout autour de la  tourner le bouton de contrôle des gaz.  Ne jamais  zone de l'appliance pour le gaz.   Veillez à odeur à  u liser des ou ls.  Si le bouton ne sera pas pousser  côté de la parole, parce que certains gaz est plus  ou tourner à la main, n'essayez pas de la réparer.  lourd que l'air et va s'installer sur le plancher.  Appelez un technicien qualifié.  Force ou une  • Garder la zone autour de l'appliance claire et  tenta ve de répara on peut entraîner un incendie  exempt de ma ères combus bles, l'essence et  ou d'explosion.  autres vapeurs inflammables et des liquides.  • N'u lisez pas ce e appliance si une par e a été  • Construc on combus ble fait référence au plafond  sous l'eau.  Appeler immédiatement un technicien ...
  • Page 47: Installa On D'instruc Ons

      Installa on d’instruc ons  Qualifica ons d'installateur   Instruc ons générales  Un professionnel agréé doit installer l'appareil,  NE FAITES PAS  inspecter et fuite de le tester avant des u liser.  La  • Le V75i et V65i n'est pas prévu pour une  garan e sera être annulée en raison de la mauvaise  installa on à l'extérieur.  installa on.  Le programme d'installa on doit posséder des  • Le V75e et V65e n'est pas prévu pour une  compétences telles que :  installa on à l'intérieur.  • classement par taille de gaz  • N'installez pas l'appareil dans une région où les  • reliant les conduites de gaz, de conduites d'eau,  fuites d'eau de l'unité ou les connexions se traduira  de vannes, de l'électricité  par dommages à la zone adjacente à l'appliance ou  • connaissance du na onal applicable, les États et  d'abaisser les planchers de la structure.  Lorsque ...
  • Page 48: Préparez-Vous À L'installa On

      Préparez‐vous à l'installa on  • L'appareil et sa vanne de gaz doivent être  Pièces incluses  débranchés de la conduite d'alimenta on en gaz  durant les essais du système en pression dépassant  • Chauffe‐eau sans Réservoir  1/2 psi (3.5 kPa ou 13,84 pouces de hauteur de  • colonne d'eau).   Contrôleur de température de MC‐91‐2 (intégrées  dans les modèles de l'intérieurs ; fourni avec les  • L'appareil doit être isolé du système de conduite  modèles de plein air)  d'alimenta on en gaz en fermant sa vanne  individuelle de coupure durant les essais du  système en pression inférieurs ou égaux à 1/2 psi  Ou ls requis  (3.5 kPa ou 13,84 pouces de hauteur de colonne  • • Clés à tube(2)  Gants  d'eau).  • • • Vous devez suivre les instruc ons d'installa on et  Pinces réglables  Verres de sûreté  ceux dans les soins et l'entre en d'admission d'air  •...
  • Page 49: Déterminez L'endroit D'installa On

    • Installez le chauffe‐eau aussi loin que possible des  l'échangeur de chaleur vidées régulièrement.  ho es de ven la on d'échappement.  • Lorsque l'accumula on d'échelle dans l'échangeur de  Installez aussi loin que possible des bouches d'air  chaleur commence à affecter les performances du chauffe‐ inlet.  Fumées corrosives peuvent être libérées par  eau, un code de diagnos c « LC# » s'affichera.  Vider  le biais de ces évents lorsque l'air n'est pas  l'échangeur de chaleur pour prévenir les dommages à elle.   apportée grâce à eux.  Échelle build up est causée par l'eau dure définie à haute  • Substances chimiques qui sont corrosifs dans la  température.  nature ne devraient pas stockées ou u lisées près  Un kit de traitement de l'eau est disponible depuis Rinnai.   de la cessa on de chauffage ou de vent de l'eau.  Ce kit fournit un contrôle de la préven on et à la corrosion  Dommages et répara on en raison de composés  calcaire supérieur par un mélange de composés de  corrosifs dans l'air n'est pas couvert par la garan e.  contrôle d'alimenta on dans l'approvisionnement en eau.    Value Series Manual  49 ...
  • Page 50     Espacements pour terminaison de cheminée (ANS Z21.10.3, CSA 4.3)            Vous devez installer une fin de vent à  DÉTAIL D'ANGLE  INSIDE TERMINATION Terminaison  INTÉRIEUR  CORNER DETAIL apporter dans l'air de combus on et  d'expulser des gaz d'échappement.  Clearance in Dédouanement en  Réf A s'applique  Ref. A also également à la  applies to ligne an cipé de  anticipated neige.  snow line SNOW NEIGE  FIXED FERMETURE  CLOSED PERMANENTE  OUVRABLE ...
  • Page 51   Dégagements addi onnels  V75e, V65e  Vérifier si les codes locaux remplacent ces habilita ons.  • Éviter les endroits de résilia on près d'un évent sécheur.  • Évitez les endroits de résilia on près d'échappement  (50 mm) entre  cuisson commercial.  (0.91 m) à évent  • terminaux au  soffite ou eve ven lé  V75i, V65i: Vous devez installer une résilia on de vent au  même niveau  moins 12 pouces du sol  ou non aérée ; ou à un  36" pont ou un porche  12" 2" V75i, V65i  (0.30 m ) à  Des considéra ons importantes pour la localisa on d'évent  l'intérieur coin  résilia on sous un soffite (ven lés ou unven lated ou vent de  (1.52 m)  60"...
  • Page 52 Vers le haut  Sur le côté  Sur le côté  to side to side to front Vers l'avant   to front Vers l'avant   to ground/bottom Vers le sol  Vers le sol  to ground/bottom Modèles d'intérieur:  V75i, V65i  Modèles extérieurs:  V75e, V65e      Jusqu'à   Jusqu'à   Jusqu'à  Jusqu'à  ma ères   ma ères   ma ères  ma ères  non‐ non‐ combus bles ...
  • Page 53   Longueur maximum de ven la on  Protec on de gel  1.  Déterminez le nombre de coudes à 90° dans le  Assurez‐vous que dans le cas de congéla on météo  système de ven la on (deux coudes à 45°  que le chauffe‐eau et ses lignes de l'eau sont protégés  comptent pour un coude à 90°. Sur les modèles  pour éviter le gel.  Dommages causés à la congéla on  R98 chaque pied de conduite semi flexible u lisée  n'est pas couvert par la garan e.  dans la longueur d'inspira on d'air équivaut à un  Perte de gel protec on peut entraîner des dégâts  coude à 90°).   d'eau d'un échangeur de chaleur de rafale ou des  2.  Référez‐vous au tableau pour trouver la longueur  conduites d'eau.  de ven la on maximum sur la base du nombre  Avec l'énergie électrique fournie, le chauffe‐eau  de coudes.   gèleront pas lorsque la température de l'air extérieur  est froide comme –22°F (‐30 ° c) pour les modèles de  Nombre de  Longueur maximum de ven la on  l'intérieurs ou est froid comme –4°F (‐20 ° c) pour les ...
  • Page 54: Liste De Vérifica On  Pour Déterminez

      Bâ  à murer  Liste de vérifica on pour déterminer  l'endroit d’installa on  □  Le chauffage de l'eau n'est pas corrosifs  composés dans l'air.  □  L'emplacement de chauffage de l'eau est  parenthèses  conforme avec les dégagements.  d'installa on de  mur  □  (Modèles d'intérieur) La ven la on prévue ne  dépassera pas la longueur maximale pour le  nombre de coudes u lisé.  □  L'emplacement d'apport résilia on/air ven la on  prévues réunit les dégagements.  1.  Iden fiez l'emplacement d'installa on et  □  L'approvisionnement en eau ne con ent pas de  confirmez que là les espacements requis seront  produits chimiques ou dépasse la dureté totale  respectés.   qui nuira à l'échangeur de chaleur. ...
  • Page 55: Installa On De La Mise À L'air Libre (Modèles D'intérieur)

      Installa on de la mise à l'air libre (modèles d'intérieur)   Installez la ven la on correcte pour votre modèle, en suivant les instruc ons du fabricant de ven la on.  Reportez‐vous à la documenta on technique du fabricant pour les numéros de pièce spécifiques et des  instruc ons.  Produits de ven la on listés  Constructeur  Téléphone  Fax  Contact  et testés (V75i, V65i)  Ubbink  Rolux Vent System   888‐835‐9320  678‐829‐1666  www.rinnai.us  custsvc@heat‐fab.com,  Heat‐Fab  Saf‐T Vent SC system  800‐772‐0739  413‐863‐4803  www.hea ab.com  Corr/Guard Vent/Air Intake  info@mtlfab.com, www.metal‐ Metal‐Fab  800‐835‐2830  316‐943‐2717  System  fabinc.com ...
  • Page 56     Installa on de conduit de cheminée  (modèles d'intérieur)           Résilia on horizontale sans u liser le collecteur de condensat  * Un collecteur de condensat est requis sur les       AVERTISSEMENT  terminaisons horizontales si une éléva on  ver cale dans le système de ven la on  Si un collecteur de condensat n'est pas u lisé, le tuyau   dépasse 5' (1,5 m).   de drainage doit être capuchonnée pour éviter que gaz  d'échappement et condensat n'entrent dans le bâ ment.   Ce capuchon est livré sur l'appareil.   Hauteur maximum *   Dans les régions à climat froid il se  5' (1,5 m)  produira plus de condensat dans le  système de ven la on. Un collecteur de  condensat est recommandé pour ces  climats.   Si plus d'un coude est u lisé dans la   sec on ver cale, vous devez u liser un  collecteur de condensat.  ...
  • Page 57: Condensat (Modèles D'intérieur)

      Condensat (modèles d'intérieur)   L’INFORMATION  La forma on de condensat peut arriver même sur les  appareils à ven la on directe de haute performance.  • Un collecteur de condensat intégré.  Pour éviter que le condensat n'endommage, suivez  • Dans les régions à climat froid il se produira plus  ces instruc ons :   de condensat dans le système de ven la on. Un  NE FAITES PAS  collecteur de condensat est recommandé climats.  • Ne perme ent pas de condensat d'entrer dans le  • Le tuyau de vidange de condensat devrait être le  chauffe‐eau.Ne perme ent pas de condensat  plus court possible et avoir un terrain à la baisse.  d'entrer dans le chauffe‐eau.  • Si le drain de condensat ob ent bloqué, un code  • Ne branchez pas le tuyau de cerveaux condensat  d'erreur s'affichera sur le contrôleur. Si cela se  directement à l'égout de pluie.  produit, le drain de condensat doit être ne oyé.  • Ne branchez pas la ligne de cerveaux condensat  •...
  • Page 58: Installa On De La Tuyauterie

    (CSA 4.3) pour tous les systèmes de  • La norme na onale américaine (ANSI Z21.10.3) ou  chauffage par eau.   canadienne (CSA 4.3) n'exigent d'u liser une soupape  de sûreté combinée à pression et à température pour  Soupape de sûreté  cet appareil. Cependant des normes locales peuvent  le demander.   NE FAITES PAS  Vannes d'isolement   • Ne bouchez pas la soupape de sûreté, et n'installez  Rinnai recommande fortement l'installa on de vannes  aucun raccord réducteur ou autre restric on dans la  d'isolement sur les lignes de l'eau chaude et froide.   conduite de déversement. Elle doit perme re un  Parce qu'ils perme ent d'isoler le chauffe‐eau de la  drainage complet de la soupape et de la conduite.   structure de la plomberie et perme re un accès rapide à  • Ne pas placer toute autre soupape de type ou fermer  vider l'échangeur de chaleur.  Flushing l'échangeur de  disposi f entre la soupape et le chauffe‐eau.  chaleur est régulièrement nécessaire dans le cadre de ...
  • Page 59   Tuyauterie recommandée pour installa on de base    Rinnai Water Heater   Rinnai Equipment List Rinnai Water Heaters RIK-KIT (Optional) (3/4" Fittings Include: 2 Unions, 2 Ball Valves, 2 Drain Valves and 1 Pressure Relief Valve.) Connexion de gaz en 3/4 po   (19 mm)  Alimenta on en gaz  Conduite de sor e d'eau chaude  Conduite d'alimenta on en eau froide  ...
  • Page 60: Liste De Vérifica On Pour Tuyauterie

    Ne oyez le filtre à eau inlet en fermant les  détec on de fuites à l'eau savonneuse, ou une  soupapes d'isolement (fermeture) entrée froide  solu on ininflammable équivalente éventuellement  et d'eau chaude.  Me re un seau sous le filtre au  (comme certaines solu ons pour détec on de fuites  bas du chauffe‐eau à a raper toute l'eau qui est  de gaz, incluant l'eau savonneuse, peuvent causer  contenue à l'intérieur de l'unité.  Dévissez le filtre  corrosion ou fissura on par contrainte, la tuyauterie  à eau.  Rincer le filtre à supprimer tous les débris.   doit être rincée avec de l'eau après le test, sauf si  Installez le filtre et ouvrir les vannes d'isolement.  vous avez pu déterminer que la solu on de détec on  u lisée n'était pas corrosive).   □  Vérifiez la pression appropriée de l'eau pour le  • U lisez toujours des connecteurs approuvés pour  chauffage de l'eau.  Pression d'eau minimum est  raccorder l'unité sur la conduite de gaz. Purgez  de 50 psi.  Rinnai recommande de 60‐80 psi pour  toujours la conduite de gaz de tous débris éventuels  des performances op males.  avant son branchement sur le chauffe‐eau;   60  Value Series Manual ...
  • Page 61 20  200  418  787  1620  BTU/heure.  30  160  336  632  1300  Exemple:  Le pouvoir calorifique du gaz naturel pour vo‐ tre emplacement est 1 000 BTU/pi3.  L'entrée de gaz de  40  137  287  541  1110  la V75i est 180 000 BTU/HR.  Appareils supplémentaires  50  122  255  480  985  à l'emplacement exigent de 65 000 BTU/hr.  Par  conséquent, les pieds cubes par heure = (180 000 + 65  60  110  231  434  892  000) / 1000 = 245 pi3/H.  Si la longueur de la conduite  est de 10 pieds puis taille du tuyau de 3/4 de pouce est  80  101  212  400  821 ...
  • Page 62: Reliez L'électricité

      Reliez l'électricité  Ajustez à l'haute al tude  V75i/e: Définissez les valeurs indiquées dans le        AVERTISSEMENT  tableau ci‐dessous pour votre al tude commutateurs  N'u lisent pas une rallonge ou un adaptateur  2 et 3 (SW1, commutateurs fauve).  Le paramètre par  brancher avec cet appareil.  défaut pour l'appliance est 0‐2000   (0‐610 m) avec  les commutateurs no 2 et 3 dans la posi on OFF.   Le chauffage de l'eau doit être électriquement fondée  Lorsque le commutateur DIP est ajusté, il n'est pas  conformément aux ordonnances et codes locaux ou,  nécessaire de régler le paramètre de pression de gaz  en l'absence de codes locaux, en conformité avec le  à haute al tude.  Code électrique de la Na on, ANSI/NFPA no 70 ou le  Code électrique canadien, CSA C22.1.  SW1   SW1   Al tude  No. 2  No. 3  Modèles d'intérieur est équipé d'un bouchon de trois  volets (échouement) pour votre protec on contre les  0‐2000   (0‐610 m)   d’arrêt   d’arrêt  chocs et devrait être branché directement dans un ...
  • Page 63: Installa On De Le Contrôleur De Température

      Installa on de le contrôleur de  Montage du contrôleur  température  1.  Faire trois trous dans le mur, comme le montre.        AVERTISSEMENT  Outline of Remote   Désac ver le pouvoir.  Ne pas tenter de connecter les  securing screw VIS  contrôleurs de température avec le pouvoir.  Bien que  le contrôleur est un disposi f de basse tension, il y a  1-21/32" TROU DE  120 volts poten els à côté les connexions de  wiring hole CÂBLAGE  3-5/16" contrôleur de température à l'intérieur de l'unité.  VIS  securing screw Ne se connectent pas le contrôleur de température  aux bornes 120VAC fournis pour les électrovannes de  drain faculta f.  2.  Exécutez le câble entre le contrôleur et le chauffe‐ eau ou le contrôleur et un autre contrôleur  Modèles de l'intérieurs ont leur contrôleur intégré  3. ...
  • Page 64: Liste De Vérifica On Finale

    □  Confirmer que l'électricité est fournie d'un acc 120,  instruc ons d'installa on du fabricant de ven la on  source d'énergie de 60 Hz, est dans un circuit bien  et ces instruc ons d'installa on.  rodé et allumé.  □  (Modèles d'intérieur)  Vérifiez que le système  □  Vérifier que le contrôleur de température  fonc onne correctement.  d'évacua on ne dépasse pas la longueur maximale  □  Pour les V75i/e, vérifiez que les commutateurs no 2  pour le nombre de coudes u lisé.  et no 3 du commutateur SW1 DIP (commutateurs  □  (Modèles d'intérieur)  Vérifier que le commutateur  no 1 du commutateur DIP SW1 (commutateurs  tan) est défini correctement pour votre al tude.    fauve) a été ajusté pour cloaque si nécessaire.   □  Vérifier que le système fonc onne correctement en  Reportez‐vous à la sec on sur la longueur maximale  vous connectant à votre manomètre vers le port de  de Vent. ...
  • Page 65: Diagramme En Escalier

      Diagramme en escalier   PHASE NEUTRE FUSIBLE 10 A CONTACT DE DÉTECTION DE GEL ANTI-FOUDRE RELAIS 2 ANTI-FOUDRE RELAIS 1 ALLUMAGE TERRE ALIMENTATION D'ÉNERGIE DE COMMUTATION 170 V CC 12,6 V 40 V CC 5 V CC 0-5 V CC DÉTECTEUR ÉLECTRO- D'ÉCOULEMENT VANNE À...
  • Page 66: Instruc Ons D'u Lisa

      Chauffe‐eau d’intérieur sans réservoir à ven la on directe  Instruc ons d'u lisa on  POUR LES APPLICATIONS INTÉRIEURES SEULEMENT  V75i ...... REU‐VC2528FFU‐US  V65i ...... REU‐VC2025FFU‐US  POUR LES APPLICATIONS EXTÉRIEUR SEULEMENT  V75e ..... REU‐VC2528W‐US  V65e ..... REU‐VC2025W‐US  Faits importants sur votre chauffe‐eau  Je vous remercie pour l'achat d'un chauffe‐eau sans réservoir Rinnai.  Pour le bon fonc onnement et la  sécurité, il est important de suivre les instruc ons et de respecter les mesures de sécurité.  Toutes les instruc ons et la garan e lire a en vement avant d'exploita on ce e chauffe‐eau.  Gardez  ce manuel en lieu sûr.  AVIS: Rinnai partage parfois des informa ons de contact client avec des entreprises que nous croyons offrent  des produits ou des services qui peuvent vous être u les.  En fournissant ces renseignements, vous  acceptez que nous pouvons partager vos coordonnées à ce e fin.  Si vous préférez ne pas avoir vos  informa ons partagées avec ces entreprises, veuillez contacter le service clientèle et demandez ne pas  d'avoir votre informa on partagée.  Nous allons cependant con nuer à vous contacter avec les  informa ons per nentes pour le produit vous inscrit ou vous rendre compte avec nous. ...
  • Page 67: Direc Ves D'opéra Ons Du Consommateur Pour Le Fonc Onnement Sécuritaire De Votre Chauffe-Eau

      Direc ves d'opéra ons du consommateur pour le fonc onnement  sécuritaire de votre chauffe‐eau     À LIRE AVANT LA MISE EN SERVICE POUR VOTRE SÉCURITÉ       AVERTISSEMENT    Si vous ne suivez pas exactement ces instruc ons, il peut en  résulter un départ d'incendie ou une explosion, causant dégâts  matériels, blessures corporelles ou même mort.  • A.  Cet appareil ne comporte pas de veilleuse. Il est muni d’un  Si vous ne pouvez rejoindre le fournisseur, appelez le  disposi f d’allumage qui allume automa quement le brûleur.  service des incendies.   Ne tentez pas d’allumer la veilleuse manuellement.    B.  AVANT DE FAIRE FONCTIONNER, reniflez tout autour de  C.  Ne poussez ou tournez la mane e d’admission du gaz qu’à la  l’appareil pour déceler une odeur de gaz. Reniflez près du  main ; ne jamais u liser d’ou l. Si la mane e reste coincée,  plancher, car certains gaz sont plus lourds que l’air et peuvent  ne pas tenter de la réparer ; appelez un technicien qualifié. Le  s’accumuler au niveau du sol.  fait de forcer la mane e ou de la réparer peut déclencher  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :  ...
  • Page 68: Comment Utiliser Le Contrôleur De Température

      Comment utiliser le contrôleur de température  Dimensions (pouces):  3.5 W x 4.75 H x 0.75 D  Le contrôleur de MC‐91‐2 est le contrôleur de température standard qui est fourni avec l'appareil de chauffage  de l'eau.  Sur les modèles de l'intérieurs, elle est intégrée dans le panneau avant.  Le contrôleur de MCC‐91‐2 est pour des applica ons hydroniques nécessitant des températures plus élevées.   Lorsque le contrôleur de MCC‐91‐2 est connecté, ces températures plus élevées sont disponibles sur tous les  modèles de contrôleur dans le système.  Reportez‐vous à la sec on sur les plages de température.  Exploiter le chauffe‐eau pas à plusieurs reprises et u lisez un robinet d'eau chaude tandis que le contrôleur est  désac vé.  Le chauffe‐eau de ce e façon de produire alterna vement l'eau chaude de fonc onnement peut  causer l'eau de condenser à l'extérieur des pièces internes et s'accumulent dans le chauffe‐eau du cabinet.  INDICATEUR  In Use EN SERVICE  Indicator INDICATEUR  Priority PRIORITAIRE  Indicator Temperature TEMPÉRATURE   Display DE L'EAU  BOUTON   Priority PRIORITAIRE  Button Temperature CHOIX DE LA  Selection TEMPÉRATURE  ALLUMEZ‐VOUS / ON/OFF ÉTEIGNEZ ...
  • Page 69: Comment Définir La Temperature

      Comment définir la température   Ce e chauffe eau nécessite un débit minimum à exploiter.  Ce taux se trouvent sur la page de spécifica on dans  ce manuel.  Dans certains cas lorsque vous n'obtenez pas l'eau chaude ou si l'eau alterne entre le chaud et le  froid, c'est en raison du débit de l'eau étant ci‐dessous ou à proximité du débit minimum.  Accroître le débit  devrait résoudre ces problèmes dans ces cas.  Si vous rencontrez des problèmes avec les réglages de température plus élevées, puis réduire le réglage de la  température.  Sélec on d'une température plus proche à celle qui est u lisée au niveau du robinet augmentera  la quan té d'eau chaude dans le robinet, en raison de moins d'eau froide mélanger à l'appareil.  L'eau chaude peut être dangereuse, en par culier pour les enfants, les            DANGER  personnes âgées et les infirmes. Il y a un risque d'échaudage si la consigne  du thermostat est réglée trop haut.   Des températures dépassant 125° F (52 °C) peuvent causer de sévères  brûlures ou un échaudage, pouvant entraîner la mort.   L'eau chaude peut causer des brûlures au premier degré suite à des  exposi ons aussi limités que :   Chaud  3 secondes à 140° F (60 °C)   20 secondes à 130° F (54 °C)   8 minutes à 120° F (49 °C)   Brûlure  Testez la température de l'eau avant de placer un enfant sous la douche  ou dans le bain.   Ne laissez pas un enfant ou une personne infirme dans une baignoire sans  surveillance.  1.  Si le chauffe‐eau est désac vée,  appuyez sur le bouton  La température peut être ajustée entre 98° F  AVIS  d'alimenta on pour ac ver la. ...
  • Page 70   Plages de température    avec un contrôleur de température  Le chauffe‐eau peut fournir l'eau à un seul réglage de la température à la fois.  Les températures disponibles  sont fournis ci‐dessous.  Une température inférieure à 98° F (37 ° C) peut être obtenue dans l'eau du robinet en  mélange à l'eau froide.  Pour modifier l'échelle de température de Celsius à Fahrenheit ou vice versa, appuyez et  tenir le bouton « On/Off » pendant 5 secondes, tandis que le chauffe‐eau est désac vée.  Plages de température disponible (Fahrenheit °F)  V75i/e, V65i/e  98   100   102   104   106   108   110   115   120   *   *   *   *   **   **   Celsius  °C  37  38  39  40  41  42  43  46  49  52  54  57   60 ...
  • Page 71: Entre En Requis

      Entre en requis  L'appareil doit être inspecté chaque année par un technicien qualifié.  Répara ons et entre en doivent être  effectuées par un technicien qualifié.  Le technicien de service doit vérifier le bon fonc onnement après entre‐ en.        AVERTISSEMENT  Pour vous protéger contre les préjudices, avant d'effectuer la maintenance :  • Coupez l'alimenta on électrique en débranchant le cordon d'alimenta on ou en désac vant l'électricité au  disjoncteur.  (Le contrôleur de température ne contrôle pas la puissance électrique).  • Coupez le gaz à la soupape de gaz manuelle, généralement situé immédiatement sous le chauffe‐eau.  • Coupez l'alimenta on en eau entrante.  Cela peut se faire à la vanne d'isolement immédiatement au‐dessous  du chauffe‐eau.  Garder la zone appliance claire et exempte de ma ères combus bles, l'essence        AVERTISSEMENT  et autres vapeurs inflammables et des liquides.  Test de la soupape ne doit être effectuée par un technicien qualifié.  L'eau        AVERTISSEMENT  chaude à ébouillanter peut‐être être libéré sous pression.  Les ar cles suivants de la maintenance sont nécessaires au bon fonc onnement de votre chauffe‐eau.  Ne oyage  Moteurs  Il est impéra f de contrôler compar ments, brûleurs  Les moteurs sont lubrifiés à vie et ne demandent pas ...
  • Page 72   Ne oyez le filtre à eau  Protec on de gel  Ne oyez le filtre à eau inlet en fermant les soupapes  Assurez‐vous que dans le cas de congéla on météo  d'isolement (fermeture) entrée froide et d'eau  que le chauffe‐eau et ses lignes de l'eau sont  chaude.  Me re un seau sous le filtre au bas du  adéquatement protégés pour éviter le gel.   chauffe‐eau à a raper toute l'eau qui est contenue à  Dommages causés à la congéla on n'est pas couvert  l'intérieur de l'unité.  Dévissez le filtre à eau.  Rincer le  par la garan e.  Reportez‐vous à la sec on sur la  filtre à supprimer tous les débris.  Installez le filtre et  Protec on de geler.  ouvrir les vannes d'isolement.  Déstéarinisa on  Valve de décompression  Ces recommanda ons visent à suggérer des pra ques  Exploiter la valve manuellement une fois par an.  Ce  qui sont efficaces pour l'apposi on du chauffe‐eau.   faisant, il sera nécessaire de prendre des précau ons  Ils devraient être u lisés comme un guide  avec ce qui a trait à l'exécu on de poten ellement  uniquement.  Aucune responsabilité ne suppose pour ...
  • Page 73: Flushing L'échangeur De Chaleur

    Pressure Relief Valve SOUPAPE PRESSION  Solenoid Valve VANNE ÉLECTROMAGNÉTIQUE  (V1).  5.  Verser 4 gallons de qualité non dilué d'alimentaire vierge, vinaigre  blanc dans le seau.  6.  Placez le tuyau de drain (H3) et le tuyau (H2) à l'entrée de la pompe  dans la solu on de ne oyage.    Rinnai 7.  Ouvrez les deux valves de service (V1 et V2) sur l'eau chaude et de  Water Heater conduites d'eau froides.  8.  Faire fonc onner la pompe et perme re à le vinaigre de ne oyage  à circuler à travers le chauffage de l'eau pendant au moins 1 heure  à un taux de 4 gallons par minute (15,1 litres par minute).  9.  Désac ver la pompe.  10.  Rincer le vinaigre de ne oyage de l'appareil de chauffage de l'eau  comme suit :  a.  Re rer le seau de l'extrémité libre du drain flexible (H3). ...
  • Page 74: Drainage Manuel Du Chauffe-Eau

      Drainage Manuel du chauffe‐eau  Pour éviter de burns, a endre jusqu'à ce que l'équipement se refroidit avant le        AVERTISSEMENT  drainage de l'eau.  L'eau de l'appliance restera chaud après qu'il est éteint.  Si le chauffe‐eau ne va être u lisée pendant une période de temps au gel possible, il est recommandé que l'eau à  l'intérieur du chauffe‐eau être drainé.  Manuellement drainer l'eau :  1.  Couper l'approvisionnement en eau froide et d'approvisionnement  en gaz.  Filtre  2.  Désac ver le contrôleur de température.  Eau  à eau   3.  Coupez l'alimenta on de l'appareil de chauffage de l'eau.  chaude  4.  Placez un conteneur pour a raper l'eau.  Supprimer les capuchons  de drain sur les deux vannes d'isolement et ouvrez les deux valves  au‐dessus des caps (poignées de valve bleu et rouge).  ‐OR‐Ouvrez  la soupape.  5.  Supprimer le filtre à eau pour drainer l'eau froide.  Pour reprendre un fonc onnement normal :  1.  Confirmer que l'approvisionnement en gaz est désac vé, et que  tous les robinets sont fermées.  2.  Vis dans le filtre à eau dans l'entrée de l'eau froide.  3.  Remplacez les capuchons de drain et fermer les deux vannes  d'isolement. ‐OR‐Fermez la soupape. ...
  • Page 75: Garan E Du Consommateur

        Garan e du consommateur                Garan e limitée  Qu'est‐ce qui est couvert ?   Ce e garan e couvre tous défauts dus aux matériaux et à la main d'œuvre quand le produit a été installé et u lisé en  suivant les instruc ons écrites d'installa on de Rinnai, dans les termes décrits dans ce document de garan e limitée. Ce e  garan e s'applique seulement aux produits qui sont installés correctement. Une installa on incorrecte pourrait annuler  ce e garan e. Rinnai vous recommande fortement d'employer un installateur qui aura suivi une classe Rinnai pour la  connaissance des produits avant d'installer le chauffe‐eau. Ce e garan e couvre l'acheteur d'origine uniquement tant que  le produit reste sur le site de son installa on ini ale. Ce e garan e ne joue qu'après la toute première installa on du  produit et se termine s'il est déplacé ou réinstallé à un autre emplacement.   Combien de temps dure la couverture ?  Période de couverture (à par r de la date d'achat) ...
  • Page 76 Toutes garan es implicites de valeur marchande et d'adéqua on à une finalité spécifique autorisées par la législa on locale  seront de toutes façons limitées en durée à la période de couverture offerte par ce e garan e limitée, sauf si la période  légale locale d'applica on est plus courte. Certains états ne perme ent pas de limita ons sur le temps que durent les  garan es implicites, de ce fait la limita on qui précède peut ne pas être applicable à votre cas.   Ce e garan e vous donne des droits légaux spécifiques, et vous pouvez également avoir d'autres droits qui peuvent varier  d'un état à l'autre.  AVIS:  Rinnai partage parfois des informa ons de contact client avec des entreprises que nous croyons offrent des produits  ou des services qui peuvent vous être u les.  En fournissant ces renseignements, vous acceptez que nous pouvons  partager vos coordonnées à ce e fin.  Si vous préférez ne pas avoir vos informa ons partagées avec ces entreprises,  veuillez contacter le service clientèle et demandez ne pas d'avoir votre informa on partagée.  Nous allons cependant  con nuer à vous contacter avec les informa ons per nentes pour le produit vous inscrit ou vous rendre compte avec  nous.  76  Value Series Manual ...
  • Page 77     Value Series Manual  77 ...
  • Page 78   78  Value Series Manual ...
  • Page 79     Value Series Manual  79 ...
  • Page 80 • Up to 0.96 Energy Factor (EF) Applications • Internal or External Installation ® • ENERGY STAR qualified models • Pair up with the Rinnai Air Handler for efficient home heating Direct Vent Furnaces • High Efficiency • Vent Terminal A Included • Cool-to-the-touch Cabinet •...

Table of Contents