WIRING
See the Installation Manual for more information.
Batteries:
Use only 1.5 volt Alkaline size-AA batteries.
External Power:
Red / Black wires - External 7.5 VDC Power Source
must be used for operation without batteries.
Remote Input:
White / White wires - Wire a Normally Open Contact
to wires (white and white). Momentarily close to allow
person to pass through door. NOTE: Remote Input
is enabled from the factory. (See page 23)
Relay:
COM-Blue / NO-Yellow / NC-Green - See page 24
(Function 67) for programming options for the Relay.
Wiring to Disarm a Burglary Control Panel
Burglary Control Panel wiring. See page 27.
POWER UP

When applying power to the lock for the first time, stop
and follow the procedure outlined in "Quick Start, First time
Power Up" further in this manual.

When power is re-applied to a lock that was already op-
erational, proceed as follows:
1. Disconnect battery pack connector.
2. With battery power disconnected, press and hold
down
;
for 10 seconds to insure discharge of all ca-
pacitors.
3. Re-connect battery pack (lock will sound 3 short beeps). If
beeps are not heard, then restart at step 1.
4. Do not press any keys for 15 seconds.
5. After 15 seconds, the LED will flash red 6 times and 6
beeps will sound.
The lock is now ready for use. The pre-existing program is
loaded from fixed memory. Set the clock using functions 38,
39 and 40.
ERASE ALL PROGRAMMING
(The "out of box" factory default will be loaded)
1. Remove the battery pack.
2. With battery power disconnected, press and hold
down
for 10 seconds to ensure discharge of all ca-
;
pacitors.
3. Re-install the battery pack (lock will sound 3 short beeps).
If beeps are not heard, then restart at step 1.
4. Within 5 seconds after hearing the 3 short beeps, press
and hold
until the lock begins to beep, then release.
;

Wiring and Power Up

BATTERY REPLACEMENT
5. A series of 5 RED LED and 5 beeps will be heard followed
by 10 seconds of silence, then 3 GREEN LEDs and 3 fast
beeps.
All settings and programming have been erased and the lock
is now ready for use. Note: All lock programming can also be
erased (without need to disconnect the batteries) by entering
Function 99.
When a valid code is entered and the batteries are weak, the
yellow LED will light and the sounder will sound for 4 seconds.
DL Series locks use five (5) AA-size 1.5 volt alkaline batteries.
Always replace weak batteries as soon as possible.
CAUTION: Do not press any keys while batteries are dis-
connected or you may erase the real-time clock settings.
1. At the back of the lock, remove the screw at the bottom of
the lock housing and remove the cover.
2. Pull out the battery pack and quickly replace all 5 batteries -
within 1 minute.
3. If you do not hear the 3 beeps when power is re-applied, all
programming and settings have been retained, and the
lock is ready for use. Go to step 5.
4. If you do hear 3 beeps when power is re-applied, do not
press any keys for 15 seconds. After the 15 second
period, the LED will flash red 6 times and 6 beeps will
sound. Reset the clock using functions 38, 39 and 40.
5. Replace the cover and tighten the screw.