CONNECTION TERMINALS
1 - 2 : TAMPER N.C.
Normally Closed contact while the keypad is secured on the box. It is open while keypad is
separated from the box. Connect this N.C. terminal to a 24 hour zone of an alarm system if
necessary.
3 - 4 : 12V DC -- POWER INPUT
Connect to 12V DC power supply. The (–) supply, Terminal (4) is the common grounding point of
the keypad. Terminal (3) is the +12V power input terminal.
6 - 7 : OUTPUT 1 -- DOOR LOCK
Output 1 is controlled by the group 1 user codes. It is a 12VDC / 3 Amp ra�ng Solid State output
contact with terminal 6 (+) and terminal 7 (–) for electric door lock actua�on. Connect the lock to
these terminals directly with correct polarity. The output has been set for Fail-Secure Electric
Lock in Default. It is programmable for Fail-Secure (energized to open) or Fail-Safe (de-energized
to open) electric lock at programming Loca�on 66.
The output contact is programmable for Start / Stop (toggle) mode or �mer mode from 1 to 999
seconds. See programming Loca�on 40-43 for the details.
8 - EG IN -- EGRESS INPUT
A Normally Open (N.O.) input terminal refers to (–) ground, with the help of a normally open
bu�on to ac�vate the Output 1 for the same �me period as like the user code. Egress bu�on is
usually put inside the house near the door.
More than one egress bu�ons can be connected in parallel to the terminal. Leave this terminal
open if it is not used.