Configura�On Of Output Modes For Outputs 1 - Transmitter Solutions DOLKSS1KB Programming & Installation Manual

Self-contained digital access control keypad
Hide thumbs Also See for DOLKSS1KB:
Table of Contents

Advertisement

Configura�on of Output Modes for Output 1
The output 1 can be programmed to trigger with the following op�ons. for a programmed length of
�me from 1 to 999 seconds; or to trigger ON and OFF in toggle with a user code; or to trigger ON
with an accelerated start code and OFF with an full digit user code.
NOTE:
Programming Loca�ons:
● Loca�ons 40, 41, 42 and 43 for Output 1
Programming Options for Output 1 (See "Programming Summary Chart" Section D for more information) :
A) Loca�on 40 : Momentary Mode with �me length from 1 to 999 seconds (Default = 1 second)
The relay outputs can be programmed to work for a �me length from
cope with the door opening required.
B) Loca�on 41 : Start / Stop Mode (toggle)
The relay outputs can be programmed to trigger ON (start) and OFF (stop) with a user code.
C) Loca�on 42 : Start / Stop Mode (toggle) with 2-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 2 digits of a user code and
OFF with a full user code.
Example:
a) User Code 8 3 2 1 is a full code, then the first 2 digit 8 3 is the accelerated code.
b) User Code 5 4 3 2 1 is a full code, then the first 2 digit 5 4 is the accelerated code.
D) Loca�on 43 : Start / Stop Mode (toggle) with 3-digit Accelerated Code
The relay outputs can be programmed to trigger ON with only the first 3 digits of a user code and
OFF with a full user code.
Example:
a) User Code 5 4 3 2 1 is a full code, then the first 3 digit 5 4 3 is the accelerated code.
b) User Code 9 2 7 0 5 3 is a full code, then the first 3 digit 9 2 7 is the accelerated code.
Loca�ons
Time Length

A)
1 – 999

B)

C)

D)
Confirm
16
(Loca�ons 40–43)

to
seconds to

Advertisement

Table of Contents
loading

Table of Contents