SET KEYPAD TO SINGLE USER MODE (to whom it may require)
This keypad also consists of a simplified version so�ware for code entry. It is single user mode for
those users only need one each user code for output 1 and the special func�ons.
Once the keypad is in single user mode, there is no User ID required for the codes, just simply enter
the code to each Loca�ons directly.
Single user mode is prepared for those users who need simple func�on and use the default values
for their keypad only. Please ignore this sec�on if it is not suitable for your applica�on.
Important Notes:
● All user codes and master code must be 4 digits. The codes of more than 4 digits will be invalid.
● Change the master code to 4 digits before refreshing the keypad to single user mode. Otherwise,
refreshing will be refused.
● Refreshing takes 2-3 seconds to complete. Do not enter any code during refreshing un�l 2
confirma�on beeps are heard.
● The keypad will be in auto code entry mode in default a�er it is refreshed to single user mode.
● The keypad can be changed back to standard mul�-user mode with the system refreshing code 8 9 0 1.
● Single user mode simplifies the procedures for code entry only. All programming procedures for
other features are exactly the same like in mul�-user mode and not affected.
● See summary chart for the "Single-User Mode" programming procedures.
Programming Summary Chart for "Single-User Mode"
A) Enter Programming Mode with Master Code
Entry of Master Code
NOTE: Factory has put a master code
for first �me use.
B) System Refreshing to Single User Mode – Installer Programming
Refresh Code
Confirm
C) Code Entries – User Programming
1) Recording Master Code and User Codes – User Programming
Loca�ons
Entry of Codes
4 digits fixed
4 digits fixed
Confirm
Comments
Set system to Programming Mode
Comments
Clear all previously stored data and set keypad back to default values except
Master Code
Confirm Comments
Owner's Master Code for se�ng system to programming mode
User Code for opera�ng Output 1
(Exit-Factory Master Code: 0 0 0 0)
into the keypad before exit-factory, owner may take it
(Default: 8 9 0 0, Single-user mode)
24
(No Default Codes)