15-1 System Specification

Specifications and additional information

Protective height
Object Resolution
Operating Range
Effective Aperture Angle
Safety Output (OSSDs)
Response Time
Auxiliary Output
(non safety)
EDM - Monitor Input
Start/Restart Input
Light Source
Transmitter Indicator Lights ACTIVE (Yellow)
Receiver Indicator Lights
Housing Material
Front Window Material
End Cap Material
Mounting Bracket Material
Wiring connections
Weight
Performance
240 mm - 1800 mm (14 mm resolution)
280 mm - 2120 mm (30 mm resolution)
14 mm and 30 mm
0.3 m - 7 m (14 mm resolution), default
0.3 m - 3 m (14 mm resolution), DIP SW 6 option
0.3 m - 20 m (30 mm resolution), default
0.3 m - 8 m (30 mm resolution), DIP SW 6 option
±5° maximum, transmitter and receiver according to
IEC61496-2 (2006)
Two PNP safety outputs, each output sourcing
625 mA @ 24 VDC.
Short circuit protection
Maximum: 59 ms
See table below for more details
One PNP output sourcing 100 mA @ 24 VDC. This out-
put follows the OSSDs.
50 mA @ 24 VDC
10 mA @ 24 VDC, Normally open input
Infrared Emitting LEDs,
Wavelength 880 nm
Power Dissipation: 180 mW
Class 1 per EN60825-1
MACHINE RUN/STOP (Green/Red)
INTERLOCK/ALARM (Yellow)
BLANKING (Amber)
Mechanical
Polyurethane powder painted aluminum
Acrylic, Red
Polycarbonate
Cold rolled Steel
M12-connectors;
8-pin receiver and 5-pin transmitter
See table for more details