!WARNING
7-1
Access to the selector switches
7-1-1
Transmitter selector switch settings
Using selector switches to set features
Make sure that foreign objects such as water, oil, or dust do not enter the
inside of the MS2800 system while the cover for the selector switches is open.
The switches are located behind a flip door on both the transmitter and
receiver. The flip up doors are opened by loosening two retaining screws (see
illustration below).
ENDCAP WITH DOOR
1
2
3
1
2
3
RECEIVER SELECTOR SWITCHES
Switch Position
1
2
2
1
ON
TRANSMITTER SELECTOR SWITCHES
(Shown in factory default positions)
SELECTOR SWITCH ACCESS
4
5
6
ON
4
5
6
ON
TRANSMITTER SELECTOR SWITCHES
Function
SCAN CODE
MTS
Scan Code
Frequency A 1 = Off
Frequency B 1 = On
MTS
Disabled 2 = Off
Enabled 2 = On
SECTION 7
SELECTOR SWITCH ACCESS
RCVR
XMTR
ON
1
2
Factory default
SCAN CODE A
MTS OFF
19