Specifications Ratings - Omron UM Series Manual

Hide thumbs Also See for UM Series:
Table of Contents

Advertisement

UM/MC3
Specifications
Ratings
Safety Mat Controller
Power input
Item
Power voltage
Operating voltage range
Power consumption *
* Power consumption of loads is not included.
Switch
Item
Rated load
Maximum rated voltage
Rated carry current
Maximum switching capacity
Characteristics
Safety Mat
Item
Detection method
Actuating force
Maximum allowable load
Mechanical durability
Material
Ambient operating temperature
Degree of protection
Weight
Safety Mat Controller
Item
Response time
Safety input
Safety output
Auxiliary output
Insulation resistance
Between different
poles of outputs
Dielectric
strength
Between power
supply and output
Vibration resistance
Mechanical shock resistance
Mechanical
Durability
Electrical
Ambient operating temperature
Ambient operating humidity
Degree of protection
Terminal tightening torque
Weight
6
Model
24 VDC
-15% to +15% of rated supply voltage
3 W max.
Model
6 A at 230 VAC/6 A at 24 VDC (resistive load)
5 A at 230 VAC (AC15)/2 A at 24 VDC (DC13) (inductive load)
250 VAC/24 VDC
6 A
1,500 VA
Model
Pressure sensing method
300 N min.
2,000 N (EN ISO 13856-1 requirement)
1 million cycles min.
PVC (Polyvinyl Chloride)
-37 to 66°C (with no icing or condensation)
IP67
Approx. 24.4 kg/m
2
Model
30 ms max.
Four-wire Safety Mat only
Mat can be connected in series (Connectable number: 12 max.)
The external impedance must be 8 Ω or less between M11 and M21 and between M12 and M22.
SPDT-NO
SPDT-NC
20 MΩ min. (at 500 VDC)
1,800 VAC, 50/60 Hz for 1 sec.
Malfunction: 10 to 55 Hz, 0.15 mm single amplitude
Malfunction: 98 m/s
2
10,000,000 cycles min.
100,000 cycles min. (rated load, switching frequency: 360 cycles/hour)
0 to 55°C (with no icing or condensation)
0% to 90% RH
IP20
0.5 N·m
Approx. 360 g
MC3
MC3
UM
MC3

Advertisement

Table of Contents
loading