UM/MC3
Specifications
Ratings
Safety Mat Controller
Power input
Item
Power voltage
Operating voltage range
Power consumption *
* Power consumption of loads is not included.
Switch
Item
Rated load
Rated carry current
Characteristics
Safety Mat
Item
Detection method
Detection weight
Material
Ambient operating temperature
Degree of protection
Weight
Safety Mat Controller
Item
Response time
Safety input
Safety output
Auxiliary output
Insulation resistance
Between different
poles of outputs
Dielectric
strength
Between power
supply and output
Vibration resistance
Mechanical shock resistance
Mechanical
Durability
Electrical
Ambient operating temperature
Ambient operating humidity
Degree of protection
Terminal tightening torque
Weight
6
Model
24 VDC
-15% to +15% of rated supply voltage
3 W max.
Model
6A at 250 VAC/6A at 24 VDC (resistance load)
5A at 250 VAC/2A at 24 VDC (inductive load)
6 A
Model
Pressure sensing method
30 kg min.
PVC (Polyvinyl Chloride)
-37 to 66°C (with no icing or condensation)
IP67
2
Approx. 28 kg/m
Model
30 ms max.
Four-wire Safety Mat only
Mat can be connected in series (27.9 m
SPDT-NO
SPDT-NC
20 MΩ min. (at 500 VDC)
1,800 VAC, 50/60 Hz for 1 min.
Malfunction: 10 to 55 Hz, 0.15 mm single amplitude
2
Malfunction: 98 m/s
10,000,000 cycles min.
100,000 cycles min. (rated load, switching frequency: 360 cycles/hour)
0 to 55°C (with no icing or condensation)
0% to 90% RH
IP20
0.5 N·m
Approx. 360 g
MC3
MC3
UM
MC3
2
max.)

Advertisement