S59: Current Slave In Communication (Default 0); S60: Reconnect Time Interval (Default 5) - Sena Parani-ESD100 User Manual

Hide thumbs Also See for Parani-ESD100:
Table of Contents

Advertisement

C.31. S59: Current Slave in Communication (default 0)
This value shows the current slave number in communication. The value is automatically stored when
the slave is selected for communication. This value can also be set by user so the master unit connects
to a specific slave to connect first in case the master unit reboots. The value range is 0~4. 0 means the
maser unit never connected to a slave. The master will connect to a slave whatever responses first.
C.32. S60: Reconnect Time Interval (default 5)
This value defines reconnect time interval in case a slave is disconnected in multiple connection mode.
The actual reconnect time interval will be the value multiplied by two in seconds. For example, if the
value is set to 5, the reconnect time interval will be 10 seconds. The value should be greater than or
equal to 5. The master unit will only try to reconnect when its mode is set to Mode1.