Specifications Of Serial Interface Com1 - Pro-face GP-4400 Series Hardware Manual

Table of Contents

Advertisement

Specifications of Serial Interface COM1

Introduction
NOTE: For instructions on how to connect to other devices, always refer to the "GP-
Pro EX Device/PLC Connection Manual".
The COM1 ports of GP-4201T and GP-4201TW are not isolated. The SG (signal
ground) and FG (frame ground) terminals are connected inside the GP unit.
Serial Interface COM1
GP-4201T: D-Sub 9 pin plug connector via an RS-232C or RS-422/RS-485 cable.
NOTE:
ELECTRIC SHOCK
When using the SG terminal to connect an external device to the panel:
Verify that a short-circuit loop is not created when you set up the system.
Connect the #5 SG terminal to remote equipment when the host (PLC) unit is
not isolated. Connect the #5 SG terminal to a known reliable ground connection
to reduce the risk of damaging the circuit.
Failure to follow these instructions will result in death or serious injury.
Pin Connection
5
9
6
1
(GP unit side)
*1
You can switch pin #9 between RI and VCC via software.
EQUIPMENT DAMAGE
Use only the rated current.
Failure to follow these instructions can result in equipment damage.
DANGER
Pin
RS-232C
No.
Signal Name
1
CD
2
RD(RXD)
3
SD(TXD)
4
ER(DTR)
5
SG
6
DR(DSR)
7
RS(RTS)
8
CS(CTS)
9
CI(RI)/VCC
Shell
FG
NOTICE
GP4000 Series Hardware Manual
Direction
Meaning
Input
Carrier Detect
Input
Receive Data
Output
Send Data
Output
Data Terminal Ready
-
Signal Ground
Input
Data Set Ready
Output
Request to Send
Input
Send possible
Input/–
Called Status Display
+5V±5% Output 0.25A
Frame Ground (Common
with SG)
*1