S301-5(D-16
(* * * * * 1)
/J-1) : Factory use
This switch is used for the adjustment in the factory.
n
Be sure to use this switch for factory setting (OFF).
(* * * * * 1)
S301-6(D-16
/J-1) : Not used
Factory setting: OFF
(* * * * * 1)
S301-7, 8(D-16
/J-1) : Physical channel setting
(*2)
Sets the physical channel
Physical channel
S301-7
CH1
OFF
CH2
OFF
CH3
ON
CH4
ON
S301-7 and S301-8 are set to OFF at the factory.
(*2) : The physical channel is the number assigned to each
processor so that the control panel can discriminate
multiple processors.
[LED]
ND301(F-1) : CPU RUN indicator
Displays a numerical indication of the operational state of
the CPU.
switch
.
S301-8
OFF
ON
OFF
ON
1-8. Switch Settings on Boards and LEDs Description
CPU-196 board (DME-7000 only)
7
COR407~COR412
6
5
4
D819~D822
3
D3
2
D2
1
A
B
C
D
E
[Switch]
S1(J-1) : Factory use
This switch is used for the adjustment in the factory.
n
Do not press this switch in normal times.
S2(J-1) : Reset switch
Resets the CPU on the CPU-196 board.
S801-1(H-1) : Memory clear switch
ON:
Erases the key frame data when the power
is turned on.
OFF:
Backs up the key frame data.
Factory setting: OFF
S801-2 through S801-5(H-1) : Factory use
These switches are used for the adjustment in the factory.
n
Be sure to use these switches for factory setting (OFF).
D802~D810
S801
S2
S1
F
G
H
J
K
L
M
A side ( Component side )
1-15 (E)