5. Introduction, Product Features and Specifications
introdUction
This alarm detects products of combustion using photoelectric technology and carbon monoxide using
an electrochemical cell. Many times throughout this User Guide, we will refer to Carbon Monoxide as "CO."
Ten (10) years after the unit is installed, this unit will automatically alert you that it is time to replace the
unit. This is called "End of Unit Life" mode. See Troubleshooting Guide. To help identify the date to replace
the unit, a label has been affixed to the side of the alarm. Write in the "Replace by" date (10 years from
initial power up) in permanent marker on the label prior to installing the unit.
ProdUct FeatUreS and SPeciFicationS:
•
Temperature: Operating Range: 4.4°C (40°F) to 37.8°C (100°F)
•
Humidity: Operating range: 10-95% RH non-condensing
•
Audible Alarm: 85+ dB at 10' 3.0 to 3.5 KHz pulsing alarm, with voice messages
"Fire!" and/or "Warning! Carbon Monoxide."
•
Smoke Sensor: Photoelectric
•
CO Sensor: Electrochemical
•
Voice message system
•
Smoke Alarm Hush
•
Ambient Light Sensing
•
Powered by 3 V DC non-replaceable sealed lithium battery.
•
Wireless interconnectable to other compatible alarms.
•
One large, user- friendly button.
8