5. Introduction, Product Features And Specifications
Introduction
This alarm detects products of combustion using a photoelectric sensor.
Ten (10) years after the unit was installed, powered up, and tested, this unit will automatically alert you
that it is time to replace the unit. This is called "End of Unit Life" mode. See Troubleshooting Guide.
To help identify the date to replace the unit, a label has been affixed to the side of the alarm. Write the
"Install date" in the space provided, and then write in the "Replace by" date (10 years from initial power
up) in permanent marker on the label prior to installing the unit.
NOTE: AC power must be connected to obtain the full 10 year battery and unit life.
Product Features and Specifications:
• Powered by 120VAC (60 Hz, 42 mA max) wire-in connector with sealed lithium battery backup
• Reduced nuisance alarms
• Self-testing (see section 10)
• Voice message system
• Easy installation
• Hardwire interconnectable to other compatible alarms
• Smoke Alarm Hush
• Smoke Sensor: Photoelectric
• Temperature Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
• Humidity Operating Range: up to 95% RH non-condensing
• Audible Alarm: 85+ dB at 10', 3.0 to 3.5 KHz pulsing alarm, with voice message "Fire!"
8