Introduction, Product Features And Specifications - Kidde 30CUA10-V User Manual

Combination photoelectric smoke & carbon monoxide alarm with hardwire interconnect & voice
Table of Contents

Advertisement

Trouble Condition
End of Unit Life
McU Failure
Stuck Button

5. Introduction, Product Features And Specifications

Introduction
This alarm detects products of combustion using a photoelectric sensor and carbon monoxide using an
electrochemical cell. Many times throughout this User Guide, we will refer to Carbon Monoxide as "CO."
Ten (10) years after the unit was installed, powered up, and tested, this unit will automatically alert you
that it is time to replace the unit. This is called "End of Unit Life" mode. See Troubleshooting Guide. To
help identify the date to replace the unit, a label has been affixed to the side of the alarm. Write the
"Install date" in the space provided, and then write in the "Replace by" date (10 years from initial power
up) in permanent marker on the label prior to installing the unit. notE: AC power must be connected to
obtain the full 10 year battery and unit life. Two labels have been provided that have important informa-
tion on what to do in case of a CO alarm. Place one label at eye level on a wall near the alarm after it is
mounted, and one near a fresh air source such as a door or window.
Product Features and Specifications:
• Powered by 120VAC (60 Hz, 42 mA max) wire-in connector with sealed lithium battery backup
• Reduced nuisance alarms
• Self-testing (see section 10)
• Voice message system
• Easy installation
• Smoke Alarm Hush
• Smoke Sensor: Photoelectric
• CO Sensor: Electrochemical
• Temperature Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
• Humidity Operating Range: 10 to 95% RH, non-condensing
• Audible Alarm: 85+ dB at 10', 3.0 to 3.5 KHz pulsing alarm, with voice messages "Fire!" and/or
"Warning! Carbon Monoxide"
8
Visual Indications
Amber LED blinks 2
times every 60 sec.
None
Amber LED blinks 4 times
every 60 sec.
TM
Audible Indications
2 chirps every 60 sec and
voice "Replace Alarm."
After 1 hour, voice occurs
only once every 15 mins.
Voice "Hush Mode Acti-
vated" after button push
(first 7 days only).
Constant Tone
3 chirps every 60 sec.
Action
* Push button once to silence for 24 hrs. (Push
button again to clear HushTM and perform a test.)
Note: 7 days after End of Unit Life begins, the
notifications cannot be silenced.
* Remove alarm, discharge, dispose unit, and
replace as soon as possible.
* Remove alarm, discharge, dispose unit, and
replace as soon as possible.
* Push button to dislodge it from being stuck.
If button cannot be unstuck, remove alarm,
discharge, dispose unit, and replace as soon
as possible.

Advertisement

Table of Contents
loading

Table of Contents