3. Other Alarm Visual and Audible Indicators

Operational Mode
normal (standby)
test (button press
when no alarm condi-
tion is present)
Smoke or co alarm
Memory (unit has
experienced a smoke
or co alarm event
within the last hour)
Smoke alarm Hush
Mode, (Hush
®
control)
co alarm reset
Locate
Smoke alarm Hush
Mode canceled
initiating alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
Green LED blink approx every
60 sec.
4 patterns of Red/Amber/Green.
Test: Red LED blinks in time with
alarm pattern.
Green LED fade on/off at test
complete
Red and Amber LED alternate on
1 sec, every 10 sec.
Red LED blinks every 2 sec.
None
None
None
Green LED blinks once per sec indi-
cating that this is the unit initiating
the alarm in an interconnected,
multiple alarm, system.
Audible Indications
Button press sound
Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4,
3, 2, 1."
3 long beeps, Voice "Fire!", 3 long
beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide,"
4 quick beeps, Voice "Test
Complete," Power on/reset sound.
Voice "Test Canceled" if button
pushed before test sequence begins.
After button push: "Smoke
previously detected" or "Carbon
Monoxide previously detected"
only on the initiating alarm unit.
After button push: "Hush Mode
Activated." Smoke alarm pattern
stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke,
Alarm cannot be Hushed" Smoke
alarm pattern continues.)
After button push: CO alarm
pattern stops.
After button push on non-initiating
unit, only initiating unit continues
alarm pattern.
Voice message "Hush Mode
Canceled."
Unit in either Smoke or CO alarm
mode.
Action/Note:
Perform Test/Hush button
press once a week to verify
proper alarm operation
* Push/release button before
the countdown ends to
cancel test.
Push test button to clear
Alarm Memory. NOTE:
standard test sequence will
follow. (Push/release button
again to cancel test).
This feature is to be used
only when a known alarm
condition, such as smoke
from cooking, activates
the alarm.
Unit is confirming if CO is
present or if it experienced a
nuisance situation. Re-alarm
means danger. Move to fresh
air and call 911.
Use this to quickly locate the
alarm source and determine
if alarm is nuisance or real.
When smoke levels drop
below the alarm threshold,
the voice message "Hush
Mode Canceled" will occur .
During alarm, the initiating
alarm red blink will be
interrupted by a green blink.