Trouble Condition
End of Unit Life
MCU Failure
Stuck Button

5. Introduction, Product Features And Specifications

Introduction
This alarm detects products of combustion using a photoelectric sensor and carbon monoxide using an
electrochemical cell. Many times throughout this User Guide, we will refer to Carbon Monoxide as "CO."
Ten (10) years after the unit was installed, powered up, and tested, this unit will automatically alert you
that it is time to replace the unit. This is called "End of Unit Life" mode. See Troubleshooting Guide. To
help identify the date to replace the unit, a label has been affixed to the side of the alarm. Write the
"Install date" in the space provided, and then write in the "Replace by" date (10 years from initial power
up) in permanent marker on the label prior to installing the unit. Two labels have been provided that
have important information on what to do in case of a CO alarm. Place one label at eye level on a wall
near the alarm after it is mounted, and one near a fresh air source such as a door or window.
Product Features and Specifications:
• Powered by 120VAC (60 Hz, 42 mA max) wire-in connector with 2 AA backup batteries
• Reduced nuisance alarms
• Self-testing (see section 10)
• Voice message system
• Easy installation
• Smoke Alarm Hush
• Smoke Sensor: Photoelectric
• CO Sensor: Electrochemical
• Temperature Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
• Humidity Operating Range: 10 to 95% RH, non-condensing
• Audible Alarm: 85+ dB at 10', 3.0 to 3.5 KHz pulsing , with voice messages "Fire!" and/or "Warning!
Carbon Monoxide"
8
Visual Indications
Amber LED blinks 2
times every 60 sec.
None
Amber LED blinks 4
times every 60 sec.
TM
Audible Indications
2 chirps every 60 sec and voice
"Replace Alarm." After 1 hour,
voice occurs only once every
15 mins. Voice "Hush Mode
Activated" after button push
(first 7 days only).
Constant Tone
3 chirps every 60 sec.
Action
* Push button once to silence for 24 hrs.
(Push button again to clear Hush
perform a test.) Note: 7 days after End of
Unit Life begins, the notifications cannot
be silenced.
* Remove alarm, dispose unit, and replace as
soon as possible.
* Remove alarm, dispose unit, and
replace as soon as possible.
* Push button to dislodge it from being
stuck. If button cannot be unstuck, remove
alarm, dispose unit, and replace as soon
as possible.