Configurable Zone Type Programming Fields - First Alert FA168CPSSIA Installation And Setup Manual

Hide thumbs Also See for FA168CPSSIA:
Table of Contents

Advertisement

Installation Instructions

Configurable Zone Type Programming Fields

The system allows you to define custom zone types (FA168CPS supports 4 [types 90-93]; FA148CP
supports 2 [types 90, 91]), based on the options described below. All configurable zone types can be
programmed via the downloader. Configurable zone types 90 and 91 can also be programmed from a
keypad using data fields *182-*185 described below.
UL installations: Do not configure zones as fire alarm or UL burglar alarm zones.
Configurable Zone Type 90
*182
0-15 = values for each of 10 entries
(0-9, # + 10 = 10, # + 11 = 11, # + 12 = 12,
# + 13 = 13, # + 14 = 14, # + 15 = 15)
Zone Type 90 Report Codes
*183
90 ALARM ID: XXX
TROUBLE ID: XXX
Use existing Contact ID® codes, if
appropriate, or define unique codes in CID
code range 750-789.
Configurable Zone Type 91
*184
see *182 for entries
Zone Type 91 Report Codes
*185
91 ALARM ID: XXX
TROUBLE ID: XXX
Configurable Zone Type Options
Auto Restore (entry 2)
Vent Zone (entry 2)
Bypass Disarmed (entry 4)
Bypass Armed (entry 4)
Dial Delay (entry 6)
Fault Delay (entry 6)
Faults Display (entry 7)
Power Reset/Verification
(entry 7)
Use Entry Delay (entry 8)
Use Exit Delay (entry 8)
Interior Type (entry 8)
Alarm Sounds (entry 9)
Bell Timeout (entry 9)
Fire Zone (entry 9)
Trouble Sounds (entry 10)
Chime Enable (entry 10)
4-12
Enter the appropriate value for each entry, 1-10, based on the charts
on the next page. To calculate the value for each entry, add the
values of the selected options in each of the entry's columns shown in
the respective chart (one option per column). For example, to
program entry 2 for "alarm response to short," "auto restore on," but
not a "vent zone," enter 5 ("1" for alarm short + "4" for auto restore-
yes + "0" for vent zone-no).
Enter the desired 3-digit Contact ID® report codes for alarms and
troubles occurring on zones assigned to this zone type.
Press [∗] to accept and continue.
Important Notice on Report Codes: To avoid confusion at the
central station, it is recommended that existing Contact ID® codes be
used with configurable zone types whenever possible. See list in
System Communication section and/or check with the central
station for a complete list of Contact ID® report codes. If none of the
codes are suitable, choose a code in the reserved range of 750-789
(reserved for configurable zone type report codes) and make sure to
define the code with your central station.
See field *182 for explanation of entries.
See field *183 for explanation of entries and read the Important
notice on using these codes.
Faults on zones set for this option are cleared; restore messages sent upon restoral of
faults.
Zones set for this option are ignored if faulted when arming the system, but are protected
if the zone is later restored (e.g., an open window can be ignored when arming, but if the
window is later closed, it will be protected; opening the window again causes an alarm.)
Zones set for this option can be bypassed only while the system is disarmed.
Zones set for this option can be bypassed when the system is armed or disarmed.
Alarms on zones set for this option participate in dial delay central station reporting, if
system dial delay enabled in field *50.
Faults on zones set for this option are delayed by the time set in field *87. Do not use this
option if using entry/exit delay for this zone type.
Selects how faults on zones set for this zone type are displayed.
Selects whether the system resets power (when user enters code + OFF), and
whether the system performs alarm verification (see description for zone type 16 in
Programming Overview section) when a fault occurs on these zones.
Selects whether to use the system's entry delay times.
Selects whether to use the system's exit delay time.
Zones set for this option are treated same as standard zone type 4 (bypasses when armed
STAY, faults displayed).
Selects the type of alarms sound for zones set for this zone type.
Alarm sounding on zones set for this option remain for the duration set in fields *32 / *33.
Zones set for this option respond in the same manner as if programmed for zone type 9.
Do not set fire zones to respond as a "fault" in entries 1-6.
Selects the type of trouble sounds for zones set for this zone type (periodic beeps = once
every 30 seconds; trouble beeps = rapid beeping).
Zones set for this option cause a chime when Chime mode is on.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa168cpsFa148cpFa148cpsia

Table of Contents