First Alert FA168CPSSIA Installation And Setup Manual page 52

Hide thumbs Also See for FA168CPSSIA:
Table of Contents

Advertisement

Installation Instructions
01 Activated By:
Zone List
"A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
6-4
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Zone List
01-08 = zone list
[∗] to continue
Zone Type
see list at right
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Do not use pager zone lists 09-12 in output definitions.
Press [ ] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
1
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [ ] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night
01 = Ent/Exit #1
06 = 24 Hr Silent
02 = Ent/Exit #2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower 09 = Fire
10 = Interior w/Delay
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Bell Timeout***
21 = Arming–Away
38 = Chime
22 = Disarming
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time 41 = **AC Power Failure
33 = Any Burglary Alarm 42 = **System Battery Low
43 = Comm. Failure
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
Any partition
0
Press [ ] to continue and skip to the "Output Action" prompt.
Press 1 to delete this
output definition.
0 = restore; 1 = alarm;
2 = fault; 3= trouble
12 = Monitor Zone
14 = Carbon Monoxide
16 = Fire w/verification
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch Zone
81 = AAV Monitor Zone
90-91 = Configurable
52 = Kissoff
54 = Fire Zone Reset
58 = Duress
60 = AAV
66 = Function Key†
67 = Bell Fail
68 = Telco line cut
78 = Keyswitch red LED
79 = Keyswitch green LED
0 = any partition; 1 = partition 1;
2 = partition 2; 3 = common

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa168cpsFa148cpFa148cpsia

Table of Contents