Installation Instructions
Option Selection
*91
0 = none
2 = Sounder Delay
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart/reset ††
Multiple choice example: for both AAV and
Exit delay restart, enter # + 12 (4 + 8).
SIA-Compliant Controls:
above.
Call Waiting Disable: 0 = call waiting not used
1 = call waiting disable digits (*70) entered in
field *40; (when selected, the system
dials the entry in field *40 only on
alternate dial attempts; this allows proper
dialing in the event call waiting service is
later canceled by the user).
4-8
Select the desired options by adding the values of each desired option.
Sounder Delay: If enabled, delays external sounding by 15-seconds.
††"Exit Delay Restart/reset" option allows use of the [∗] key to restart
the exit delay at any time when the system is armed STAY or
INSTANT. This feature also enables automatic exit delay reset, which
resets exit delay if the entry/exit door is re-opened and closed before
exit delay time expires after arming AWAY. Automatic Exit Delay
Reset occurs only once during an armed period.
Options: Same as
IMPORTANT: AAV should not be used when Paging or Alarm
Reports are sent to a secondary number unless the monitoring zone
option is used (which pauses calls). Otherwise, the call to the
secondary number by the communicator after the alarm report will
prevent the AAV from taking control of the telephone line, and the
AAV "Listen in" session cannot take place.
U L
UL installations using the AAV feature must use the ADEMCO UVCM
module (part of the ADEMCO UVS system).
Exit Delay Restart/Reset must be disabled.
SIA Guidelines: Exit delay should be enabled.
If sounder delay is used, entry delay (*35) must be 30 sec. max.