First Alert FA168CPSSIA Installation And Setup Manual page 26

Hide thumbs Also See for FA168CPSSIA:
Table of Contents

Advertisement

Installation Instructions
Interactive Mode Programming (∗ ∗ ∗ ∗ 56, *57, ∗ ∗ ∗ ∗ 58, ∗ ∗ ∗ ∗ 79, ∗ ∗ ∗ ∗ 80, ∗ ∗ ∗ ∗ 81, ∗ ∗ ∗ ∗ 82)
Entering Interactive Mode
Loading Factory Defaults/Initializing for Download
To Load Default Entries
To Initialize Download ID
Do not press 97 to load defaults if any programming has been done previously—data already
programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code reentry
Allow installer code reentry
Table of Device Addresses
This Device
RF Receiver
AUI 1 (FA168CPS only)
AUI 2 (FA168CPS only)
Long Range Radio
FA4286 Voice Module
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 zones 33 - 40
module 5 zones 41 - 48
Relay Modules (4204):
module 1
module 2
module 3
module 4
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
5800TM Module
† 4219/4229 addresses 9-11 and 4204 addresses 14-15 apply to the FA168CPS.
†† Addressable devices are identified by "1" plus the device address when reporting. Enter a report code for zone 91 to enable
addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit
identification keypad display options.
3-6
Press [ ∗ ] + [Interactive Mode No.] (for example, ∗ 56) while in Program Mode.
The Alpha display keypad will display the first of a series of prompts
requesting entries.
After making the appropriate entry, press the [∗] key to accept the entry and
continue to the next prompt.
Press ∗97 while in Program Mode. This resets all data fields to the default
values shown on the Program Form. Use ∗ 97 only if you wish to return to the
original factory-programmed defaults.
Press ∗96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if ∗ 98 was
used to exit, you must first power the system down. Then power up again,
and press [∗] and [#] at the same time, within 50 seconds of powering up.
See field *88 for other Program mode lockout options.
Press ∗99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at the same time,
within 50 seconds of power-up.
††
Uses Address Reports as
00
100
01
101
02
102
03
103
04
104
07
107
08
108
109
09
110
10
111
11
12
112
13
113
114
14
115
15
16
n/a
17
n/a
18
n/a
19
n/a
20
n/a
21
n/a
22
n/a
23
n/a
28
n/a
Enabled By...
*56 zone programming: input device type entry
automatic if AUI enable field *189 enabled for AUI 1
automatic if AUI enable field *189 enabled for AUI 2
automatic if output to long range radio field *29 enabled
automatic if phone module access code field *28 enabled
*56 zone programming: input device type, entry 2, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
automatic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa168cpsFa148cpFa148cpsia

Table of Contents