5800 Series Transmitter Input Loop Identification

All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the input
loops requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
LOOP 3
LOOP 4
YOU MUST
ENROLL
LOOP 2
THIS
BUTTON
LOOP 1
5 8 0 1
ENROLL AS
"UR" OR "RF"
LOOP 1
5808
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
(REED)
(TERMINALS)
LOOP 1
LOOP 3
(TERMINALS)
(TERMINALS)
5 8 1 9
ENROLL AS "RF"
Compatible 5800 Series Transmitters Table
Model
Product
5801
Wireless Panic
Transmitter
5802
Pendant
Emergency Transmitter)
5802CP
Belt Clip (Personal
Emergency)
5802MN
Miniature (Personal
Emergency Trans.)
5804
Wireless Key
Transmitter
5804BD
Bi-Directional
Wireless Key
5806
Wireless
5807
Photoelectric Smoke
5808
Detectors
5809
Heat Detector
5816
Door/Window
Transmitters
5816MN
5816TEMP
Low-Temp. Sensor
LOOP 4
O N
YOU MUST
O F
F
ENROLL
LOOP
THIS
1
BUTTON
5802MN
ENROLL AS
5804
"UR" OR "RF"
ENROLL AS "BR"
LOOP 2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
5816
5816MN
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
LOOP 1
(INTERNAL
SHOCK
SENSOR
5819S (WHS & BRS)
5850 (GBD)
ENROLL AS "RF"
ENROLL AS "RF"
Input Type
UR or RF
BR Only
(Personal
BR Only
UR or RF
BR Only
BR
RF
RF
RF
RF
LOOP 2
LOOP 3
LOOP 4
LOOP 2
YOU MUST
ENROLL
LOOP 1
THIS BUTTON
LOOP 3
LOOP 1
SET
HOUSE
CODE
5 8 0 4 B D
ENROLL AS "BR"
LOOP 1
(PRIMARY)
LOOP 2
LOOP 2
(AUX.
(REED)
CENTER)
LOOP 1
LOOP 3
(TERMINALS)
(AUX.
RIGHT)
5817
ENROLL AS "RF"
LOOP
1
MOTION
(Green)
(Red)
(Yellow)
5890
ENROLL AS
"RF" OR "RM"
V20P-006-V0
Description
• Four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Panic, Arm, Disarm, etc.)
• Has single pushbutton.
• Usually programmed for response type of 24-Hr audible or 24-Hr
Silent (other zone responses are possible).
Same as 5802.
Same as 5802.
• Has four pushbuttons, each with a unique input (loop) code.
• Programmable responses (e.g., Arm, Disarm, etc.)
• House ID must be set.
• Requires 5800TM Transmitter Module.
• Can indicate system status via its 2 LEDs and built-in sounder.
• Has four pushbuttons, each with a unique input (loop) code.
• Operates the system similarly to wired keypads.
One-piece smoke detectors with a built-in transmitter.
One-piece rate-of-rise heat detector with a built-in transmitter.
Has two unique input (loop) codes: one for a wired closed circuit
contact loop; the other for its built-in reed switch (used with a
magnet).
Transmits a fault condition when temperature drops below 45°F.
NOTE: For information on any transmitter not
shown, refer to the instructions accompanying
that transmitter for details regarding loop
numbers, etc.
UL NOTE: The following transmitters are
not intended for use in UL
installations:
5802MN, 5802MN2, 5804,
5804BD, 5814, 5816TEMP,
5819, 5819WHS & BRS, and
5850.