FIELD
TITLE and DATA ENTRIES
Cancel Verify Keypad Display
*86
0 = no
1 = yes
Misc. Fault Delay Time
*87
0 = 15 secs
6 = 2-1/2 min #+12 = 8 min
1 = 30 secs
7 = 3 min
2 = 45 secs
8 = 4 min
3 = 60 secs
9 = 5 min
4 = 90 secs
#+10 = 6 min
5 = 2 min
#+11 = 7 min
Program Mode Lockout Options
*88
0 = standard *98 installer code lockout
1 = lockout [∗] + [#] reentry after *98 exit (reentry
via installer code only)
2 = not used
3 = lockout all local programming after *98 exit
(reentry via downloader only)
Event Log Full Report Code
*89
0 = no report
1-F = see description above *59
Event Log Enables
*90
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of
entries)
EXPLANATION
When enabled (1 = yes), this feature causes a "ALARM
CANCELED" display at the keypad under the following conditions:
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
When an alarm is successfully canceled before the Central
Station received the Alarm message. E.g., if an alarm is
incorrectly triggered and the user presses code + OFF before
the dial delay time has expired, the message will never go out
to the CS.
When the Cancel report is not enabled and system is disarmed:
a. before dialer delay expires (alarm report not sent) message
"Alarm Canceled" is displayed.
b. after dialer delay expires, "Alarm Canceled" not displayed .
Used with zones assigned to a configurable zone type with fault
delay on (configurable zone type digit "6"), and sets a zone
response time of 15 seconds to 15 min. It can be assigned to zones
#+13 = 10 min
#+14 = 12 min
with sensors that provide a trouble indication when an oil tank is
#+15 = 15 min
low, or similar applications for critical condition monitoring
where a non-alarm response is desired.
UL: May only be used on non-burglar alarm and non-fire alarm
zones when used on a fire and/or UL burglar alarm installation.
Select the desired options. The following table summarizes the
Program mode lockout options:
Exit
Command Entry Installer
*99
*98
*98
*98
pressing [∗] + [#] within 50 seconds of power up
If an Event Logging selection is made in field ∗90, a message can be
sent to the central station receiver when the log is 80% full. If the log
becomes full, new messages overwrite the oldest messages in the log.
This system has the ability to record various events in a history log
(FA168CPS = 100 events; FA148CP = 50 events). At any time, the
downloader operator can then upload the log and view or print out all
or selected categories of the log. The downloader operator can also
clear the log. Event log can also be viewed at an alpha keypad.
The display/printout at the central station will show the date, time,
event, and description of the occurrences.
Data Entry Example: To select Alarm/Alarm Restore" and
"Open/Close", enter 9 (1+ 8); to select all events, enter #15.
*88
Reentry By:
Power-up† Downloader
n/a
yes
yes
0
no
yes
1
yes
no
3
no
no
yes
yes
yes
yes
4-7