3=Walktest; 4: Time-Date - Honeywell FIRE-LITE MS-10UD Series Manual

Fire alarm control panels
Hide thumbs Also See for FIRE-LITE MS-10UD Series:
Table of Contents

Advertisement

Maintenance Programming Level
To view all the events which have occurred in the control panel since the history file was last erased, press 1 while viewing the Events
screen. To view only alarms/active events which have occurred, press 2 while viewing the Events screen. To view events other than
alarms, press 3. The most recent event will be displayed on the screen. To view all of the selected events, press the up or down arrow
keys to scroll through the list of events. If no events have occurred, the display will read NO EVENTS IN HISTORY.
Pressing 2 while viewing the History Screen will cause the following screen to be displayed:
Pressing 1 while viewing the Erase History Screen will erase all events from the History file. The display will then return to the History
Screen. Pressing 2 will cause the display to return to the History Screen without erasing the History file.
3.6.3 Walktest
PROGRAMMING
1=INPUT ZONES
2=HISTORY

3=WALKTEST

Maintenance Screen #1
The operator can press 1 to perform a silent walktest or 2 to perform an audible walktest. The display will read UNIT IN WALKTEST. To
end the Walktest, press the Esc (Escape) key.
Pressing 3 after the walktest has been completed, will allow the operator to view the results of the walktest.
3.6.4 Time-Date
PROGRAMMING
1=TIME-DATE
Maintenance Screen #2
To change the time, press 1 to display the following screen:
A flashing cursor will appear on the left side of the display. Enter the four digit number corresponding to the time (0000 - 1259). When
the fourth digit is entered, the cursor will move one position to the right. Press 1 for AM or 2 for PM to complete entering the time. The
display will return to the Time and Date Screen displaying the new time.
To change the date, press 2 while viewing the Time and Date Screen. The following screen will be displayed:
A flashing cursor will appear on the left side of the display. Enter the two digit month, two digit day and four digit year. The cursor will
move one position to the right after each entry. When the fourth digit of the year has been entered, the display will return to the Time and
Date Screen which will show the new date.
To change between 12 hour and 24 hour format, press 3 while viewing the Time and Date screen. Each press of the 3 key will toggle the
display between 12 HR and 24 HR format.
MS-5UD & MS-10UD Series Manual — P/N 52626:C7 6/12/2018
ERASE HISTORY
1=YES
Erase History Screen
To perform a walktest, press 3 while viewing Maintenance Screen #1. The following screen will be dis-
played:
WALKTEST
1=SILENT
2=AUDIBLE
3=VIEW RESULT
Walktest Screen
To program the time and date into the control panel, press 1 while viewing Maintenance Screen #2. The
following display will appear:
TIME AND DATE
1=TIME
2=DATE
3=CLOCK FORMAT 12HRS
Time and Date Screen
ENTER TIME AS 12HRS
1=AM
ENTER DATE
--
MONTH DAY YEAR
06-15-2018
PROCEED?
2=NO
01:00 AM
06-09-2018
:
01:00 AM
2=PM
Time Screen
Date Screen
Programming
95