Auto Power-on Select

JP9 is used to select the method of powering on the system. If you want the system to pow-
er-on whenever AC power comes in, set JP9 pins 2 and 3 to On. If you want to use the power
button, set pins 1 and 2 to On.
When using the JP9 "Power On" feature to power the system back on after a power failure
occurs, the system may not power on if the power lost is resumed within 5 seconds (power
flicker).
Chapter 2 Hardware Installation
Chapter 2
1
2
3
1-2 On:
Power-on via power button
(default)
JP9
1
2
3
2-3 On:
Power-on via AC power
12

LVDS Panel Power Select

JP6 is used to select the power supplied with the LVDS LCD panel.
Important:
Before powering-on the system, make sure that the power settings of JP6 match the
LCD panel's specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
6
5
JP6
4
3
2
1
1-2 On: +12V
6
5
4
3
2
1
3-4 On: +5V
6
5
4
3
2
1
5-6 On: +3.3V
(default)