Auto Power-On Select; Lvds Panel Power Select - DFI SU173 User Manual

Mini-itx industrial
Hide thumbs Also See for SU173:
Table of Contents

Advertisement

Auto Power-on Select

JP16 is used to select the method of powering on the system. If you want the system to
power-on whenever AC power comes in, set JP16 pins 2 and 3 to On. If you want to use the
power button, set pins 1 and 2 to On.
When using the JP16 "Power On" feature to power the system back on after a power failure
occurs, the system may not power on if the power lost is resumed within 5 seconds (power
flicker).
Chapter 2 Hardware Installation
Chapter 2
1
2
3
1-2 On:
Power-on via power button
(default)
JP16
1
2
3
2-3 On:
Power-on via AC power
12

LVDS Panel Power Select

JP13 is used to select the power supplied with the LVDS LCD panel.
Important:
Before powering-on the system, make sure that the power settings of JP13 match
the LCD panel's specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
6
5
JP13
4
3
2
1
1-2 On: +12V
6
5
3
4
2
1
3-4 On:+5V
6
5
4
3
2
1
5-6 On: +3.3V
(default)
www.dfi.com